Experiments › Chemistry
At what point does it melt?
Determining Melting Temp
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can two identical-looking white powders melt at totally different temperatures?
Show the answer
Yes! Every pure crystalline substance has a unique melting fingerprint. Today you will heat tiny crystals and watch them melt under magnification to identify an unknown chemical.

Introduction
Why does sugar melt while salt stays solid?
Sugar and salt look almost identical on your kitchen table, but warm them in a pan and sugar melts into smooth golden syrup while salt stays completely solid. The temperature where a solid turns into a liquid is called its melting point. Today you will learn about melting points, and by measuring the exact temperature where a crystal melts, you will discover the identity of a mystery white powder.
Driving question: How can measuring the exact temperature at which a crystal melts reveal what it is made of?
What you will learn
Today you will find out
- I can explain what a melting range is and why pure solids have one.
- I can load and pack a tiny crystal sample into a glass capillary tube.
- I can spot when crystals first turn wet and when they become fully liquid.
- I can find the melting range on a graph and identify my mystery substance.
- I can describe why chemists and medicine makers test melting points.
Why it matters: Pharmaceutical scientists test melting points to prove life-saving medicines are pure and free of harmful impurities.
Safety first
Safety Rules for the Melt Station
- Wear splash goggles and lab aprons at all times during this lab.
- Purple gloves = teacher does it. Blue gloves = you do it.
- The Melt Station heater block gets extremely hot (up to 260°C). Never touch the metal heat slots.
- Look for the ADULT NEEDED badge on high-temperature operations.
- Capillary tubes have ultra-thin glass. Handle them gently so they do not snap.
- Never inhale chemical dust or taste any laboratory compound.
- Wash your hands with soap and water before you leave the laboratory.
What you need
- Go Direct Melt Station1 per group
- Tablet running Graphical Analysis1 per group
- glass capillary melting tubes4 tubes
- mortar and pestle1 set
- white chemical powder0.5 g unknown sample
- short PVC pipe section1 vertical glass drop tube (1 m)
- Lint-free tissue box1 box
- Splash goggles and nitrile gloves1 per student

Step 1 of 8 Teacher does this
Set up and connect the Melt Station
- Have an adult connect the power adapter to an electrical wall outlet.
- Turn on Bluetooth or plug the USB cable into your tablet.
- Open Graphical Analysis. Connect the Go Direct Melt Station.
- The bench surface is completely dry.
- The power cord is kept flat and out of walkways.
- The dial starts on the blue fan position.
- Make sure that the Melt Station dial is at the fan position.
Careful: Damaged power cords or wet surfaces can cause electrical hazards. Make sure that an adult checks and connects the power cord. Keep all water away.

Step 2 of 8
Grind solid to a fine powder
- Place a pea-sized amount of your unknown solid into the mortar.
- Gently grind the crystals with the pestle until it is a fine powder.
- Fine powders pack tightly and melt evenly without trapped air pockets.
- Goggles are worn over eyes.
- Do not lean directly over the mortar so you do not breathe dust.
Careful: Chemical dust can irritate eyes or the nose. Grind with a smooth circular motion. Never blow on the powder.

Step 3 of 8
Pack the capillary tube
- Press the OPEN end of the capillary tube gently into the powder pile.
- Use a tissue to wipe away loose powder on the outside.
- Invert the tube. Tap the closed end on the bench to pack a 3 to 4 mm column.
- Check that the bottom end of the tube is truly sealed glass.
- Handle glass tubes gently and do not squeeze them hard.
- Aim for a tightly packed powder column about 3 to 4 mm deep.
Careful: Thin glass capillary tubes can snap if pressed forcefully onto hard desks. Tap gently and vertically. If glass breaks, ask your teacher for help.

Step 4 of 8
Insert tube and adjust view
- Carefully slide the capillary tube into one of the three heating slots on top.
- Rotate the tilt body of the Melt Station up or down for a comfortable angle.
- Look through the magnifier observation window.
- The heating block is currently cool.
- The tube slides in smoothly without force.
- Confirm that your white powder plug is centered clearly in the illuminated view.
Careful: If you force a tube into an occupied or dirty slot, the glass can snap inside. Drop the tube in gently; it should slide freely to the bottom stop.

Step 5 of 8 Teacher does this
Run Trial 1 for rapid ballpark melt
- Tap Collect in Graphical Analysis.
- Turn the Melt Station control dial to 180°C.
- Tap 'Mark' when powder turns wet, then tap 'Mark' again and tap Stop when melted.
- The heating block reaches over 150°C during this step.
- Keep hands away from the top openings of the Melt Station.
- The red heat light turns on when the dial is at 180°C.
- Watch the sample closely through the magnifier window as the temperature climbs.
Careful: The heating block gets very hot. Touching it causes burns. Only touch the control dial and base. Keep fingers away from top slots.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 11, Chemistry, chapter 2: Organic Chemistry: Some Basic Principles and Techniques
- Related Level AS & A Level, Chemistry, chapter 4: Chemical bonding
- Direct Level AS & A Level, Chemistry, chapter 18: Carbonyl compounds
Versions and what each needs
- At what point does it melt?
Organic Chemistry, 60 min, Based on a Vernier lab
Needs: Go Direct Melt Station
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.