Experiments › Chemistry
Can a drink hide secret colours?
Separating Molecules
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can a single purple drink hide secret colours?
Show the answer
A purple soda looks like one colour, but two different dye molecules are mixed inside. Scientists study light absorption and chromatography to uncover them, and today you will unmix the secret colours.

Introduction
The Secret Molecules in Food Colouring
Look closely at green candy or dark soda. Is it made of one single dye, or a blend of several colours? When molecules are mixed in water, your eyes cannot tell them apart. In this lab, you act like a chemical detective. First, you shine rainbow light through the dyes to record their light fingerprints. Then, you use paper chromatography to make the molecules race across paper and separate.
Driving question: Can light and paper reveal the secret colours hiding in a mystery mixture?
What you will learn
Goals for this lab
- I can identify pure dyes by where their light absorption peaks appear.
- I can explain why overlapping light peaks can hide a dye in a mixture.
- I can set up paper chromatography to separate a dye mixture into pure colours.
- I can explain why different dye molecules travel different distances on paper.
- I can name real-world forensic and food safety uses for chromatography.
Why it matters: Forensic scientists and food safety labs use chromatography and light sensors every day to detect banned dyes and solve crimes.
Safety first
Safety Rules for Separation Lab
- Wear splash goggles, lab apron, and nitrile gloves throughout the lab.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Keep all flammable alcohol solvents away from heat, sparks, and electrical outlets.
- Never taste or drink any lab liquid, even if the label shows food dye.
- Look for the ADULT NEEDED badge. Adults dispense flammable liquids and pair electronic devices.
- Keep open liquids at least 30 cm away from tablets and the SpectroVis sensor.
- Wash your hands fully with soap and water after you touch dyes and solvents.
What you need
- Go Direct SpectroVis Plus Spectrophotometer1 per station · teacher
- Tablet running Graphical Analysis1 per group
- Plastic cuvette (4 clear sides)4 per group
- Test tubes and rack1 rack with 4 test tubes
- Plastic Beral pipets4 pipets
- circular filter paper3 cut strips (2 cm x 12 cm)
- 100 mL beakers2 beakers
- Distilled water wash bottle1 wash bottle
- commercial liquids30 mL 70% isopropanol solvent · teacher
- Lint-free tissue box1 box
- pencil1 wooden pencil and plastic ruler

Step 1 of 8 Teacher does this
Power and pair the spectrophotometer
- Start Vernier Spectral Analysis on your tablet.
- Select your sensor from the Bluetooth list. Tap Connect.
- Choose 'Absorbance vs. Wavelength' to scan across full rainbow colours.
- Benchtop is dry and clear of open liquid containers.
- Sensor LED blinks to confirm battery power.
- Tablet Bluetooth is enabled.
- An adult powers on the Go Direct SpectroVis Plus spectrophotometer.
Careful: Accidental liquid spillage on sensor electronics can damage optical detectors. Keep dye containers and open beakers at least 30 cm away from the sensor.

Step 2 of 8
Calibrate with distilled water
- Fill a clean cuvette three-quarters full with distilled water.
- Place the cuvette into the SpectroVis Plus well with clear sides in the light path.
- In Spectral Analysis, tap Calibrate, wait for warmup, and tap Finish Calibration.
- Cuvette holds only clear distilled water.
- Clear optical faces are free of smudges and liquid drops.
- Hold cuvette only by top ridged sides and wipe clear faces with lint-free tissue.
Careful: Smudges or micro-bubbles block light and skew all absorbance readings. Tap the cuvette gently to remove air bubbles. Wipe the cuvette with a lint-free tissue.

Step 3 of 8
Scan the pure dye standards
- Use a clean pipet to fill cuvettes with pure Red 40, Yellow 5, and Blue 1.
- Put each cuvette into the SpectroVis Plus. Tap Collect. Tap Stop.
- Record the wavelength (nm) of the highest hill peak for each pure dye.
- Separate pipets used for each colour to avoid contamination.
- Cuvettes are three-quarters full and do not overflow.
- Wipe each cuvette carefully with a lint-free tissue before you insert it.
Careful: If you mix up pipets, you contaminate standards and get false secondary peaks. Dedicate one labelled pipet to each colour.

Step 4 of 8
Scan the mystery dye mixture
- Rinse a cuvette with a small amount of the mystery dye mixture. Then fill the cuvette.
- Put the cuvette into the SpectroVis Plus well. Tap Collect. Tap Stop.
- Look at the peaks: do you see three distinct hills, or do some overlap?
- Cuvette exterior is dry and clean.
- Clear faces aligned with sensor light path.
- Wipe the sides of the cuvette clean with lint-free tissue.
Careful: Bubbles or lint scatter light and artificially raise absorbance. Examine the cuvette against a white card. Wipe it clean before you test.

Step 5 of 8
Prepare the chromatography paper strip
- Use a ruler and graphite pencil to draw a faint straight line 1.5 cm from the bottom.
- Dip the tapered tip of a plastic pipet into the concentrated mystery dye.
- Touch it briefly onto the pencil line to make a small dot (about 2 mm wide). Let it dry.
- Use pencil only, never pen ink.
- Handle paper only by the very top edge to keep finger oils off the strip.
- Take a 2 cm x 12 cm strip of chromatography paper.
Careful: Ink from a pen dissolves and ruins results. A large wet puddle causes wide streaks. Keep the dot tiny (2 mm). Let it dry. Touch it once more if it is too faint.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 11, Chemistry, chapter 2: Organic Chemistry: Some Basic Principles and Techniques
Versions and what each needs
- Can a drink hide secret colours?
AP Chemistry, 80 min, Based on a Vernier lab
Needs: Go Direct SpectroVis Plus Spectrophotometer
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.