Experiments › Chemistry

Can a fading colour tell time?

Reaction Kinetics of Food Dye and Bleach

Grades 7-8Chemistry2 versions

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

A bright blue cotton cloth soaking in a white household basin with the blue colour slowly fading

Wonder

Can a fading blue liquid count down minutes like a clock?

Show the answer

When bleach meets blue dye, the color vanishes at a steady speed. Scientists call this the reaction rate, and today you will measure it.

A notebook open to notes about chemical timing next to two sealed glass vials of blue and clear liquids

Introduction

Can Fading Color Tell Time?

Investigators discovered an unclaimed backpack in an airport terminal holding a mystery circuit and two vials. One vial held blue food dye; the other held dilute bleach. When mixed together, the color slowly disappears. Could a fading chemical reaction trigger a light sensor after an exact number of minutes? Today you will measure how fast the color fades to uncover the secret countdown.

Driving question: How can a fading color reaction act as a secret countdown timer?

What you will learn

Today you will find out

  • I can identify which color of light blue dye absorbs most.
  • I can observe and record how light absorption drops over time.
  • I can use a graph to find the half-life of a chemical reaction.
  • I can handle cuvettes and run the spectrophotometer safely.
  • I can explain how fading reactions act as timers in real life.

Why it matters: From freshness badges on milk cartons to forensic timelines, fading chemical reactions measure time without batteries.

Safety first

Lab Rules for Today

  • Always wear splash goggles and protective gloves. Bleach irritates eyes and skin.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • The teacher measures and dispenses the diluted bleach solution.
  • Look for the ADULT NEEDED badge on steps that use bleach.
  • Keep all liquids at least 30 cm away from the tablet and sensor.
  • Wipe up any spilled liquid immediately with paper towels. Wash your hands.

What you need

  • Go Direct SpectroVis Plus Spectrophotometer1 per group · teacher
  • Plastic cuvette (4 clear sides)2 cuvettes with caps
  • Tablet running Graphical Analysis1 per group
  • 100 mL beakers1 per group
  • 10 mL graduated cylinders2 per group
  • Plastic Beral pipets2 per group
  • blue liquid in a reagent bottle20 mL per group
  • clear solution in a reagent bottle15 mL diluted bleach per group · teacher
  • Distilled water wash bottle50 mL per group
  • Lint-free tissue box1 box per bench
  • Splash goggles and nitrile gloves1 set per person
Student fingers holding cuvette by top rim while wiping sides with a soft tissue

Step 1 of 6

Prepare a water blank cuvette

  1. Use a pipette to fill one clean plastic cuvette three-quarters full with distilled water.
  2. Snap a cap securely onto the cuvette.
  3. Wipe the sides clean with a lint-free tissue.
Stop and check
  • Make sure that you wear splash goggles and gloves.
  • Work area is clean and dry.
  • Hold the cuvette only by the top edges so you do not smudge the clear sides.

Careful: Smudges or water drops on the cuvette scatter light and give false readings. Pinch only the top rim of the cuvette. Wipe all four faces fully.

Student placing cuvette of water into the SpectroVis Plus slot

Step 2 of 6

Calibrate the spectrophotometer

  1. In Spectral Analysis, choose Absorbance vs. Time (Kinetics).
  2. Place your water cuvette into the sensor slot with clear sides aligned to the light beam.
  3. Wait for the sensor lamp to warm up. Tap Finish Calibration to set 100% clear water.
Stop and check
  • The sensor is dry and sits flat on the bench.
  • Clear sides of cuvette face the light beam path.
  • Open the Spectral Analysis app on your tablet and connect the SpectroVis Plus.

Careful: Calibration with colored liquid makes all future absorbance numbers completely wrong. Make sure that the cuvette contains pure distilled water before you tap Finish Calibration.

Tablet screen displaying full absorbance spectrum with a tall peak selected at 635 nm

Step 3 of 6

Find the peak color absorbed by blue dye

  1. In your second cuvette, add equal parts blue dye solution and distilled water, then cap securely.
  2. Invert twice to mix gently. Wipe the sides. Put the cuvette into the sensor slot.
  3. Tap the tallest peak on the graph at about 635 nm (red light). Tap Done.
Stop and check
  • The cuvette cap is firmly closed before you invert the cuvette.
  • Clear faces are wiped dry.
  • Look at the full spectrum curve on the tablet screen.

Careful: If you select the wrong wavelength, the color change is too small to see during the reaction. Select the highest peak on the curve, which should be red light at 635 nm.

Adult pouring clear bleach while student holds cylinder of blue dye

Step 4 of 6 Teacher does this

Measure the dye and bleach solutions

  1. Use one clean 10 mL cylinder to measure exactly 10 mL of blue dye solution.
  2. The adult measures exactly 10 mL of diluted bleach into the second 10 mL cylinder.
  3. Place both cylinders side by side next to an empty 100 mL beaker.
Stop and check
  • An adult handles the dilute bleach bottle.
  • Goggles and gloves are on all participants.
  • Cylinders are placed securely in the centre of the table.
  • Keep a clean, empty cuvette and cap ready.

Careful: Bleach can splash if you pour it carelessly. This can irritate skin and stain clothes. Only the adult dispenses the bleach. Pour slowly at eye level on a stable surface.

Student pouring the mixed solution into a cuvette while teammate prepares to tap Collect on tablet

Step 5 of 6

Mix reactants and load the cuvette quickly

  1. Pour the 10 mL blue dye and 10 mL dilute bleach into the 100 mL beaker. Swirl for 2 seconds.
  2. Quickly fill your empty cuvette three-quarters full from the beaker.
  3. Wipe the sides of the cuvette. Put the cuvette into the sensor slot immediately before you press Collect.
Stop and check
  • Beaker and empty cuvette are ready within easy reach.
  • Spectrophotometer slot is empty and ready for the cuvette.
  • One team member is ready at the tablet to tap Collect.
  • Read this entire step before you start. The reaction starts immediately when the liquids mix!

Careful: If you hesitate or wait too long, you miss the early part of the countdown curve. Pour the liquids. Swirl gently. Fill the cuvette. Insert the cuvette. Tap Collect within 10 to 15 seconds.

1 more step, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

Cambridge AS & A Level
  • Related Level AS & A Level, Chemistry, chapter P1: Practical skills 1
IB Diploma
  • Direct Level DP, Chemistry, chapter Reactivity 2.2: How fast? The rate of chemical change

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.