Experiments › Chemistry

Can a single drop cancel an acid?

Acid-Base Neutralization

Grades 7-8Chemistry3 versions

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

A kitchen table with a clear drinking glass of water where an antacid tablet fizzes next to fresh lemon slices

Wonder

Can a single drop change a harsh acid into harmless saltwater?

Show the answer

When an acid and a base mix, they cancel each other out to form water and salt. Scientists call this neutralization, and today you will find the exact turning point where it happens.

Two glasses of liquid showing red and blue colours on an indicator scale

Introduction

How to Cancel an Acid

Have you ever taken an antacid when your stomach felt sour? The antacid is a base that cancels out harsh stomach acid. In chemistry, this process is called neutralization. But how do scientists know exactly how much base is needed to cancel an acid completely? They add the base drop by drop while watching the pH. In this lab, you will watch a solution jump from acidic to basic in a split second!

Driving question: Can we find the exact drop that cancels out an acid?

What you will learn

Today you will find out

  • I can explain what happens to pH during neutralization.
  • I can spot the sudden steep jump on a pH graph.
  • I can find how much base cancels out the acid from my graph.
  • I can safely run a titration setup with my team.
  • I can name real-life uses of acid-base neutralization.

Why it matters: Water treatment plants, medicine factories, and farmers all use neutralization every day to keep liquids safe and balanced.

Safety first

Scientist Rules for Today

  • Always wear splash goggles and nitrile gloves. Acids and bases can burn skin and harm eyes.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Look for the ADULT NEEDED badge. An adult must measure the acid and fill the buret.
  • Never taste or touch any lab liquid.
  • Keep tablet and electronics at least 30 cm away from the Stir Station to avoid wet splashes.
  • If any chemical touches your skin, tell your teacher immediately and rinse under cold water for 15 minutes.

What you need

  • Go Direct pH Sensor1 per group
  • Go Direct Drop Counter1 per group
  • Stir Station1 per group
  • magnetic stir bar1 per group
  • buret1 (50 mL) per group · teacher
  • buret clamp1 per group
  • 250 mL beaker1 per group
  • 10 mL graduated cylinders1 per group
  • 0.10 M Sodium hydroxide solution60 mL per group · teacher
  • 0.1 M Hydrochloric acid solution15 mL per group · teacher
  • Distilled water wash bottle1 per group
  • Splash goggles and nitrile gloves1 set per person
Adult pouring acid into cylinder while student adds water to beaker

Step 1 of 7 Teacher does this

Add acid, water, and stir bar to beaker

  1. Transfer the 10 mL of acid into your clean 250 mL beaker.
  2. Add 50 mL of distilled water to the beaker. Make sure that the water fully covers the sensor tip.
  3. Gently drop the white magnetic stir bar into the beaker.
Stop and check
  • Everyone has goggles and gloves on.
  • The beaker sits flat on the table tray.
  • Distilled water is ready.
  • An adult has poured 10 mL of the acid solution into a 10 mL graduated cylinder.

Careful: Acid splashes can irritate skin and cause eye damage. The adult pours the acid. Pour slowly down the beaker wall so that the acid does not splash.

Beaker on Stir Station with magnetic stir bar spinning calmly

Step 2 of 7

Place beaker on Stir Station and start gentle stirring

  1. Place the 250 mL beaker on the centre plate of the Vernier Stir Station.
  2. Turn the speed knob slowly until the stir bar spins smoothly and does not splash.
Stop and check
  • The beaker is centred on the plate.
  • The stir bar spins flat and does not rattle.
  • A small, calm vortex should form in the liquid.
  • Never turn the speed too high, or the liquid will splash outside.

Careful: A stir bar that spins too fast can throw drops of acid out of the beaker. Turn the knob gradually to low or medium speed only.

Teacher filling the buret with sodium hydroxide solution

Step 3 of 7 Teacher does this

Clamp and fill the buret

  1. Have an adult clamp the 50 mL buret to the Stir Station support post.
  2. Have the adult carefully fill the buret with 0.10 M NaOH solution up to near the 0.0 mL line.
  3. Place a small waste beaker underneath. Open the valve for 1 second to clear air bubbles.
Stop and check
  • Adult wears purple gloves and goggles.
  • The buret clamp holds the glass tube firmly and does not crush it.
  • The stopcock stays tight before you pour.
  • Check that the stopcock valve at the bottom is completely closed (horizontal).

Careful: Sodium hydroxide solution can spill from the top of the buret onto eyes or skin. Use a small funnel. Pour below eye level. Wipe any drips immediately.

Student guiding the pH sensor into the Drop Counter slot above the beaker

Step 4 of 7

Attach the Drop Counter and pH Sensor

  1. Slide the Go Direct Drop Counter onto the Stir Station support post.
  2. Unscrew the storage bottle from the Go Direct pH Sensor and rinse the bulb with distilled water.
  3. Slide the pH Sensor through the large hole in the Drop Counter into the liquid.
Stop and check
  • The pH sensor tip does not touch the stir bar as it spins.
  • The Drop Counter is clamped firmly.
  • The storage bottle is safely capped on the tray.
  • Make sure that the liquid fully covers the glass tip. The tip must stay 5 mm above the stir bar as it spins.

Careful: The stir bar can strike and shatter the glass pH bulb as it spins. Look from the side. Keep at least 5 mm space between the bulb and the stir bar.

Overhead view showing buret tip aligned with drop counter opening

Step 5 of 7

Align the buret tip over the Drop Counter

  1. Carefully lower the buret tip so that it sits about 1 cm above the Drop Counter window.
  2. Check your live initial pH reading on the tablet before you add any base.
Stop and check
  • The buret tip aligns with the center of the window.
  • The beaker is placed directly below to catch all drops.
  • The initial pH reads below 3.
  • Look from above. Make sure that a drop falls straight through the teardrop window.
  • The drops must fall through the center of the window and not touch the sides.

Careful: Drops that hit the plastic body will stick and fail to register on the counter. Look from two sides. Make sure that you center the tip over the open window.

2 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Direct Class 11, Chemistry, chapter 6: Equilibrium
Cambridge AS & A Level
  • Direct Level AS & A Level, Chemistry, chapter 3: Atoms, molecules and stoichiometry
  • Related Level AS & A Level, Chemistry, chapter 21: Further aspects of equilibria
  • Direct Level AS & A Level, Chemistry, chapter P1: Practical skills 1
  • Direct Level AS & A Level, Chemistry, chapter P2: Practical skills 2
IB Diploma
  • Related Level DP, Chemistry, chapter Reactivity 2.1: How much? The amount of chemical change

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.