Experiments › Physics
Can a toy spring become a magnet?
Magnetic Field in a Slinky
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 9 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can you turn a metal toy spring into an invisible magnet?
Show the answer
When electric current runs through a coiled spring, it becomes a magnet. Today you will measure this invisible magnetic field inside the coils.

Introduction
Can a Toy Spring Become a Magnet?
You have probably played with a walking metal Slinky. But did you know it can also become a powerful magnet? When electric current flows through coiled wire, it creates a magnetic field. Engineers call this coil a solenoid. Solenoids power doorbells, car starters, and medical MRI scanners. Today, you will use a sensitive sensor to measure the magnetic field inside your Slinky.
Driving question: Can a simple coiled toy spring turn into a controllable magnet?
What you will learn
Today you will discover
- I can explain how electricity creates a magnetic field inside a coil.
- I can observe that more electric current makes a stronger magnetic field.
- I can conclude how turn density changes magnetic field strength.
- I can position and zero the magnetic field sensor inside the spring.
- I can name machines in daily life that use wire coils as magnets.
Why it matters: Electromagnets run electric motors, bullet trains, and hospital MRI scanners. Knowing how coils concentrate magnetism lets engineers control invisible forces.
Safety first
Laboratory Safety Rules
- Purple gloves = teacher does it. Blue gloves = you do it.
- Look for the ADULT NEEDED badge. Only an adult sets and adjusts the DC power supply.
- Do not touch bare metal wires while the 2 A current flows.
- The Slinky can get warm if current is left on. Turn current to 0 A between measurements.
- Never connect the power supply clips directly to each other; that causes a short circuit.
- Keep magnets, phones, and iron objects away from the coil during tests.
What you need
- Go Direct 3-Axis Magnetic Field Sensor1
- benchtop DC power supply1 · teacher
- metal coil spring1 metal Slinky
- meter stick1
- electrical wire with alligator clips2 connecting wires
- roll of tape1 roll masking tape
- Tablet running Graphical Analysis1

Step 1 of 9
Stretch and tape the Slinky
- Place the meter stick flat along the lab bench.
- Stretch the metal Slinky out until it is exactly 1.0 meter long.
- Use tape at both ends to hold the Slinky firmly to the table.
- Table is wooden or non-magnetic; no steel plates underneath.
- The tape holds firmly so the spring will not snap back.
- Check that the coils are spaced evenly, about 1 to 2 cm apart.
Careful: A stretched spring can snap back suddenly if tape lets go. Press tape down firmly on both ends. Keep face away from the spring line.

Step 2 of 9
Count turns and connect wire leads
- Count the total number of turns between the taped ends (for example, about 72 turns).
- Record your turn count in your notes.
- Clip one wire lead to one end of the Slinky and the second wire lead to the opposite end.
- The power supply is in the OFF position or unplugged before you attach wire clips.
- Alligator clips grip clean metal on the Slinky end loops.
Careful: Loose alligator clips can slip off and brush against each other. Clip firmly onto the end rings of the spring. Keep clips pointed outward.

Step 3 of 9 Teacher does this
Adult connects and tests the power supply
- An adult connects the red wire to the positive terminal and yellow wire to the negative terminal.
- The adult switches on the DC power supply and adjusts it briefly to 2.0 A to confirm current flows.
- Have the adult turn the current dial back down to 0.0 A before the test.
- Power cord is safely plugged into a grounded wall socket.
- Current dial starts at 0.0 A.
- Wires do not cross over metal bench edges.
Careful: High current can overheat wires if shorted directly. Only the teacher touches the power supply controls. Keep current at 0.0 A until ready.

Step 4 of 9
Pair sensor, select Y-channel, and set mode
- Turn on the Go Direct 3-Axis Magnetic Field Sensor. Pair it in Graphical Analysis with Bluetooth.
- In Sensor Channels, turn ON the 'Y magnetic field' channel (±5 mT). Turn OFF X and Z channels. Tap Done.
- Tap Mode. Change Mode to Event Based. Enter Current as Event Name and A as Units. Tap Done.
- The sensor power LED flashes green.
- Bluetooth is enabled on your tablet.
Careful: If you select the wrong channel (like ±130 mT), small magnetic readings look flat. Choose Y magnetic field on the ±5 mT setting for high sensitivity.

Step 5 of 9
Position and zero sensor in coil
- Insert the sensor wand between the coils near the middle of the Slinky (around the 50 cm mark).
- Align the wand so the Y-axis label points straight down the long center tunnel of the spring.
- Keep the power supply at 0.0 A. Tap the Magnetic Field Y meter. Choose Zero to reset to 0.00 mT.
- Power supply is at 0.0 A.
- The sensor wand sits in the center of the coil and does not touch the metal wires.
- No steel scissors or magnets near the table.
Careful: If you set zero while current flows, the sensor subtracts the coil magnetism and gives backwards data. Make sure that the power supply shows 0.0 A before you tap Zero.
4 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 8, Science, chapter 4: Electricity: Magnetic and Heating Effects
- Direct Class 10, Science, chapter 12: Magnetic Effects of Electric Current
- Direct Class 12, Physics, chapter 4: Moving Charges and Magnetism
- Direct Class 10, Physics, chapter 9: Electromagnetism and Magnetic Effects and Electromagnetic Induction
Versions and what each needs
- Can a toy spring become a magnet?
Physics with Vernier, 50 min, Based on a Vernier lab
Needs: Go Direct 3-Axis Magnetic Field Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.