Experiments › Chemistry
Can an acid have two turning points?
Titration Diprotic Acid
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why do some acids make two giant leaps on a pH graph?
Show the answer
Most acids neutralize in one steady jump. But some special molecules hold two acidic units. Today you will track both jumps and uncover the mystery acid's secret identity!

Introduction
The Mystery Two-Step Acid
When an acid meets a base, they cancel each other out. For simple acids like vinegar, this happens all in one go. But some acid molecules carry two acidic units packed inside. As you add base drop by drop, the acid releases its first unit, pauses, and then releases its second unit! In this experiment, you will watch this two-step reaction happen live on your screen and use the data to name our mystery powder.
Driving question: Can an acid have two different turning points when you neutralize it?
What you will learn
Today you will find out
- I can explain why a two-step acid has two jumps on its pH graph.
- I can set up the drop counter and pH sensor to collect titration data.
- I can find the two turning point volumes on a pH graph.
- I can prove that the second turning point volume is double the first.
- I can name everyday jobs that rely on chemical titrations.
Why it matters: Food scientists test sour candies, environmental chemists test acid rain, and pharmacists ensure medicines have the exact chemical strength. Titrations make those tests possible.
Safety first
Lab Safety Rules
- Wear splash goggles and gloves at all times. Base and acid solutions irritate skin and eyes.
- Purple gloves = teacher does it. Blue gloves = you do it.
- An adult must handle solid unknown acid and 0.1 M sodium hydroxide (base).
- Keep all liquids away from tablet computers and sensor electronic ports.
- If any chemical touches your skin, rinse immediately with cold water for 15 minutes.
- Never taste or drink anything in the laboratory.
- Wash your hands fully with soap and water after cleanup.
What you need
- Go Direct pH Sensor1
- Go Direct Drop Counter1
- Stir Station1
- plastic 60 mL reagent reservoir1 · teacher
- white chemical powder0.120 g in vial · teacher
- 0.10 M Sodium hydroxide solution60 mL · teacher
- 250 mL beaker1
- magnetic stir bar1
- Distilled water wash bottle1
- Splash goggles and nitrile gloves1 set per person

Step 1 of 6 Teacher does this
Dissolve the unknown acid
- The teacher carefully transfers about 0.120 g of unknown acid into the 250 mL beaker.
- Add 100 mL of distilled water from a graduated cylinder.
- Swirl gently until all crystals dissolve into a completely clear liquid.
- Everyone wears splash goggles and gloves.
- Beaker is clean and placed on a flat surface.
- Distilled water is ready.
Careful: Acid powder can irritate skin or eyes if spilled. An adult pours the solid powder into the water. Do not stir with bare fingers.

Step 2 of 6
Clamp the Drop Counter and reservoir
- Attach the Go Direct Drop Counter to the support rod of the Stir Station.
- Clamp the 60 mL reagent reservoir directly above the Drop Counter hole.
- Make sure both blue valves on the reservoir are in the horizontal closed position.
- Clamps are finger-tight and sturdy.
- Reservoir is aligned directly over the Drop Counter window.
Careful: Loose clamps can let equipment slip down the rod. Tighten the thumb-screws firmly with fingers. Do not over-force.

Step 3 of 6 Teacher does this
Fill the reservoir with base
- Pour about 60 mL of 0.10 M NaOH solution into the top reservoir.
- Place a small waste beaker under the tip.
- Turn both valves vertical for one second to fill the tip, then shut them horizontal.
- An adult wears purple nitrile gloves and goggles.
- A waste beaker is placed under the tip to catch prime drops.
- 1. Check that both blue valves are closed (horizontal).
Careful: Sodium hydroxide solution can irritate skin and damage tablet screens. Prime the tip over a waste beaker. Keep tablets at least 30 cm away.

Step 4 of 6
Position beaker, stir bar, and pH sensor
- Slide the beaker with dissolved acid onto the Stir Station platform.
- Gently drop the white magnetic stir bar into the center of the beaker.
- Unscrew the storage bottle and insert the pH Sensor through the Drop Counter hole.
- Rinse the pH glass bulb with distilled water before you insert it.
- Make sure that the probe is near the side, not in the center.
- Glass tip is positioned near the outer wall, well clear of the stir bar.
Careful: The stir bar can strike the thin glass bulb of the pH sensor and smash it. Position the probe at the outer edge of the beaker. Test the spin speed before you start.

Step 5 of 6 Teacher does this
Adjust drop flow rate
- Place a 10 mL graduated cylinder directly below the Drop Counter slot.
- Fully open the bottom valve: adjust the top blue valve until drops fall at 1 drop every 2 seconds.
- Close the bottom valve once the rate is steady and slide the acid beaker under the slot.
- The beaker is directly beneath the Drop Counter hole.
- Waste drops land safely in the beaker.
- Bottom blue valve is closed (horizontal).
Careful: Drops that fall too fast can overwhelm the sensor and cause wrong volume counts. Aim for a slow, steady rhythm: one drop every two seconds.
1 more step, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 10, Chemistry, chapter 10: Sulphuric Acid
- Related Level AS & A Level, Chemistry, chapter 27: Organic nitrogen compounds
Versions and what each needs
- Can an acid have two turning points?
Chemistry with Vernier, 60 min, Based on a Vernier lab
Needs: Go Direct Drop Counter, Go Direct pH Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.