Experiments › Chemistry

Can electricity catch an acid?

Conductimetric Titrations

Grades 7-8Chemistry1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

A clear drinking glass of lemon water with rising fizz bubbles next to a fresh cut lemon half on a wooden kitchen table in sunlight

Wonder

Can an electric current tell when a sour acid gets cancelled out?

Show the answer

Dissolved charged particles carry electric current through liquids. When an acid and a base cancel each other, the current drops to its lowest dip. Scientists call this conductimetric titration, and today you will measure that exact turning point.

A glass of water with salt dissolving and sliced lemons on a sunny kitchen table

Introduction

Can Electricity Catch an Acid?

When you stir table salt into water, the liquid carries electricity. Why? Dissolved salt splits into charged particles called ions. Strong acids are packed with fast-moving hydrogen ions, so they conduct electricity powerfully. But what happens when you add a base drop by drop? The acid ions and base ions lock together to form pure water. The electric current steadily falls until every drop of acid is gone. Then, extra base sends the current climbing right back up! Today, you will use this electric dip to find the exact strength of a mystery acid.

Driving question: Can an electric current pinpoint the exact moment an acid is neutralized?

What you will learn

Today you will find out

  • I can explain how dissolved ions allow water to conduct electric current.
  • I can spot the lowest dip on a conductivity graph as the neutralization point.
  • I can calculate the strength of an unknown acid from the volume of base used.
  • I can measure liquid volume from a buret and record steady conductivity values.
  • I can explain how factories and water plants use conductivity to check water purity.

Why it matters: Water treatment plants, battery manufacturers and chemical factories use conductivity sensors every second to guard against chemical leaks and balance solutions.

Safety first

Scientist Rules for Today

  • Wear splash goggles, protective apron and nitrile gloves throughout the lab.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Hydrochloric acid and sodium hydroxide are corrosive liquids that can burn eyes and skin.
  • Only your teacher dispenses concentrated stock solutions and fills the tall buret.
  • If any chemical touches your skin, flush immediately with cool tap water for 15 minutes.
  • Keep tablet devices and cables at least 30 cm away from all open beakers.
  • Wash your hands fully with soap and water after cleanup.

What you need

  • Go Direct Conductivity Probe1 per group
  • Stir Station1 per group
  • Electrode Support1 per group
  • buret1 50 mL buret · teacher
  • buret clamp1 per group
  • ring stand1 per group
  • 250 mL beaker1 per group
  • 100 mL graduated cylinder1 per group
  • magnetic stir bar1 per group
  • Distilled water wash bottle1 per group
  • 0.1 M Hydrochloric acid solution10.0 mL of ~0.50 M unknown HCl
  • 0.10 M Sodium hydroxide solution60 mL of ~1.00 M NaOH solution
  • Tablet running Graphical Analysis1 per group
Teacher pipetting hydrochloric acid into a glass beaker

Step 1 of 8 Teacher does this

Adult dispenses the mystery acid

  1. Your teacher uses a 10 mL pipet and safety bulb. They dispense exactly 10.00 mL of unknown HCl into your 250 mL beaker.
  2. Stand one step back while your teacher measures corrosive acid.
  3. Confirm the beaker is clean and dry before the acid enters.
Stop and check
  • Everyone has chemical splash goggles and gloves on.
  • The 250 mL beaker sits flat in the centre of the work area.
  • No other liquids or food are nearby.

Careful: Hydrochloric acid splashes can cause skin and eye burns. The adult pipets carefully with a safety bulb; never pipet by mouth. Students watch from a safe distance.

Student pouring distilled water into the beaker with acid

Step 2 of 8

Dilute the acid with distilled water

  1. Measure about 90 mL of distilled water with the 100 mL graduated cylinder.
  2. Carefully pour the water into the beaker with your acid. This step makes the total liquid volume about 100 mL.
  3. Drop in the magnetic stir bar gently so liquid does not splash.
Stop and check
  • Use only distilled water from your wash bottle, not tap water.
  • Pour smoothly along the inside wall of the beaker.

Careful: A stir bar that drops heavily can splash acidic liquid or crack the glass bottom. Tilt the beaker slightly and slide the magnetic stir bar gently down the side.

Beaker spinning smoothly on top of Stir Station with LEDs lit

Step 3 of 8

Place beaker on the Stir Station

  1. Place the beaker squarely onto the top platform of the Vernier Stir Station.
  2. Turn the speed dial to setting 3 or 4 to stir gently.
  3. Make sure that the stir bar spins smoothly in the centre. Do not let it clatter or splash.
Stop and check
  • The beaker is centred on the Stir Station platform.
  • The power cord is routed safely away from walkways.

Careful: A speed that is too fast creates a wild vortex. This vortex sucks air bubbles into the liquid. Keep the dial at a moderate speed so the liquid surface stays calm.

Conductivity probe submerged in the beaker held by the clamp

Step 4 of 8

Position the Conductivity Probe

  1. Attach the Electrode Support clamp to the metal rod of the Stir Station.
  2. Slide the Go Direct Conductivity Probe into the clamp holder.
  3. Lower the probe into the beaker. Submerge the bottom hole fully under the liquid.
Stop and check
  • The probe clamp is tightened securely to the support rod.
  • The bottom hole of the probe is fully underwater.
  • The stir bar spins at least 1 cm away from the probe.
  • Make sure that you place the probe to the side. The stir bar must never hit the probe.

Careful: If the stir bar strikes the probe, it can crack the probe body or scratch the electrodes. Position the probe near the side wall of the beaker, well clear of the centre.

Teacher pouring sodium hydroxide into a tall buret using a funnel

Step 5 of 8 Teacher does this

Adult fills and mounts the buret

  1. Your teacher fills the 50 mL buret slightly above 0.0 mL with 1.00 M NaOH.
  2. The teacher drains a few drops into a waste cup to fill the buret tip with liquid.
  3. Record the exact start buret reading to two decimal places (e.g., 0.00 mL).
Stop and check
  • The buret stopcock is closed tight before you pour.
  • The buret is clamped below eye level to prevent spills on faces.
  • Students remain seated with goggles on.
  • The buret is clamped vertically above the beaker.

Careful: Sodium hydroxide solution is caustic and causes severe burns if spilled from above eye level. Only the adult pours the base with a small funnel below eye level. Wipe any drips immediately.

3 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 12, Chemistry, chapter 4: Amines

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.