Experiments › Physics
Can electricity jump between coils?
Faraday Alternating Current
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
How does your phone charge wirelessly without any metal touching?
Show the answer
Electricity does not need touching wires to travel. By rapidly changing a magnetic field inside one coil, you push electricity into another coil across empty space. Today you will measure this invisible power transfer.

Introduction
The Magic of Invisible Energy Transfer
When you plug an appliance into a wall, wires carry the current. But how does an electric toothbrush or a wireless charger receive power with no bare metal contacts? Over 190 years ago, scientist Michael Faraday discovered that electricity and magnetism share a two-way street. A moving magnet creates electricity in a wire. Even cooler, changing the electric current in one coil makes electricity leap into an entirely separate coil resting inside it. Today, you will build that very transformer and track the invisible waves on a graph.
Driving question: Can electricity jump across empty space between two completely separate coils of wire?
What you will learn
Today you will find out
- I can explain how alternating current makes a changing magnetic field.
- I can detect voltage created inside a coil with no battery attached.
- I can compare the slopes of a current graph to the height of the voltage graph.
- I can wind an 80-turn coil and connect test probes safely.
- I can describe how wireless chargers and power transformers work.
Why it matters: Every power substation, phone adapter, electric vehicle charger, and generator relies on Faraday's law of induction.
Safety first
Scientist Rules for Today
- Wear safety goggles and lab gloves throughout the experiment.
- Purple gloves = teacher does it. Blue gloves = you do it.
- The Vernier Power Amplifier produces electrical currents up to 1 Ampere and connects to wall power. Only an adult plugs, powers, or adjusts the amplifier.
- Coils can warm up during continuous high-frequency use. Never touch wires when current flows.
- Always turn off the Power Amplifier before you adjust wire clips or move coils.
- Keep water, drinks, and all liquids completely away from the electronic equipment.
- Wash your hands fully after you handle copper wire and sandpaper.
What you need
- Vernier Power Amplifier1 · teacher
- Frequency Generator1 · teacher
- Go Direct Current Probe1
- Go Direct Voltage Probe1
- wire solenoid coil1
- short PVC pipe section1 (fits inside solenoid)
- spool of insulated copper wire1 spool (enameled magnet wire)
- electrical wire with alligator clips2 to 4 leads
- sandpaper sheet1 piece
- roll of tape1 roll
- Tablet running Graphical Analysis1

Step 1 of 8 Teacher does this
Set up the Power Amplifier and Generator
- Have an adult connect the Frequency Generator CH1 port to Power Amplifier Audio In.
- Set the Frequency Generator to a triangle waveform, amplitude 0.3, and frequency 25 Hz.
- Observe the digital display settings.
- Power Amplifier power switch is turned OFF.
- BNC to 3.5 mm audio cable is securely plugged in.
- The bench area is dry and clear of liquids.
- Keep the Power Amplifier switched OFF for now.
Careful: Incorrect voltage amplitude could overheat the coils or exceed the sensor limits. Only an adult adjusts signal generator controls and mains power connections.

Step 2 of 8 Teacher does this
Wire the primary solenoid and current probe
- Connect a black clip lead from the Power Amplifier black terminal to one solenoid post.
- Connect the Go Direct Current Probe red clip to the Power Amplifier red terminal.
- Connect the Current Probe black clip to the other solenoid post.
- The amplifier is OFF while you attach leads.
- Clip leads grip the terminal posts firmly. The leads do not touch each other.
Careful: Accidental short circuit between amplifier terminals can trip internal protection. Follow the series loop carefully: black to coil, coil through sensor, sensor to red.

Step 3 of 8 Teacher does this
Test the primary triangle wave
- Have the adult switch on the Power Amplifier.
- Tap Collect in Graphical Analysis to observe 5 to 6 crisp triangle peaks.
- Have the adult switch off the Power Amplifier to let the coil rest.
- All hands are clear of the primary solenoid wires.
- The Current Probe is zeroed and ready.
Careful: If you leave the amplifier on continuously, the coil can heat up. Run data collection for 0.25 s, examine graph, then turn the amplifier switch OFF.

Step 4 of 8
Wind your 80-turn secondary search coil
- Leave 20 cm of wire for a lead. Wind exactly 80 neat, tight turns of wire around the middle of your PVC pipe.
- Secure the windings tightly with a strip of tape.
- Leave another 20 cm of wire at the finish and snip it from the spool.
- The wire is smooth with no kinks.
- The turns sit closely side-by-side and do not tangle.
- Leave 20 cm of loose copper wire at the start before you wind.
Careful: Loose windings can slip off during insertion. Keep tension on the wire with your thumb and tape both ends securely.

Step 5 of 8
Sand wire ends and connect Voltage Probe
- Scrape the shiny brown enamel layer from the last 2 cm of both wire leads with sandpaper.
- Clip the red and black leads of the Go Direct Voltage Probe to these bare copper ends.
- Connect the Voltage Probe in Graphical Analysis. Set its range to Voltage - 1 V.
- Enamel dust is wiped onto a paper towel.
- Voltage probe clips pinch bare copper firmly.
- Confirm bare, shiny salmon-pink copper metal is visible on both sanded ends.
Careful: Unscraped enamel insulates the wire. It blocks all electrical contact and gives a zero reading. Sand all sides of the wire tip until the color turns from dark brown to bright pinkish copper.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 12, Physics, chapter 6: Electromagnetic Induction
- Direct Class 12, Physics, chapter 7: Alternating Current
- Related Class 10, Physics, chapter 9: Electromagnetism and Magnetic Effects and Electromagnetic Induction
- Related Level AS & A Level, Physics, chapter 21: Alternating currents
Versions and what each needs
- Can electricity jump between coils? (function generator)
Advanced Physics, 75 min, Based on a Vernier lab
Needs: Go Direct Current Probe - Can electricity jump between coils? (power amplifier)
Advanced Physics, 50 min, Based on a Vernier lab
Needs: Go Direct Current Probe, Go Direct Voltage Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.