Experiments › Chemistry
Can light measure liquid strength?
Beers Law
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 9 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can shining light through a drink tell you how strong it is?
Show the answer
Yes! Colored liquids swallow light. Darker liquids swallow more light. Scientists call this light absorption and concentration, and today you will measure it.

Introduction
How Strong Is the Blue Liquid?
Imagine you have two glasses of blue fruit drink. One is mixed with lots of water, making it pale. The other is deep and dark. You can see which is darker, but how do you measure its exact strength without tasting it? When light passes through, a darker liquid swallows more light. Scientists call this light absorption. Today, you will measure light shining through blue liquids to discover the exact strength of a mystery sample.
Driving question: Can a beam of light reveal the exact strength of a mystery blue liquid?
What you will learn
Today you will find out
- I can explain why a blue liquid soaks up red-orange light.
- I can dilute a liquid carefully to make known strengths.
- I can observe how liquid strength changes the light absorbed.
- I can find the strength of a mystery liquid using a graph line.
- I can name real-world tests that use light to measure liquid purity.
Why it matters: Medical labs measure chemicals in blood with light. Environmental scientists check river pollutants the same way.
Safety first
Lab Safety Rules
- Always wear safety goggles and protective lab gloves.
- Copper sulfate solution causes skin and eye irritation. Never touch your face or eyes.
- Never taste or drink any liquid in the lab.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Keep liquids at least 30 cm away from the tablet and sensor.
- Rinse any skin splash immediately with lots of water. Tell your teacher.
What you need
- Go Direct SpectroVis Plus Spectrophotometer1 per group
- Plastic cuvette (4 clear sides)1 or 2
- Test tubes and rack6 tubes in 1 rack
- 10 mL graduated cylinders2
- 0.40 M copper (II) sulfate solution30 mL in beaker · teacher
- Unknown copper (II) sulfate solution15 mL in beaker · teacher
- Distilled water wash bottle1 bottle
- Lint-free tissue box1 box
- Tablet running Graphical Analysis1

Step 1 of 9 Teacher does this
Adult prepares the solutions
- Your teacher prepares the 0.40 M copper sulfate stock solution.
- Your teacher also pours a small beaker of unknown copper sulfate solution for your group.
- Take your group beakers back to your workstation carefully.
- Everyone has safety goggles and gloves on.
- Work table is clear of books and clutter.
- Liquid beakers are kept in a spill tray.
Careful: Concentrated copper solution irritates skin and eyes if it splashes. Carry beakers with two hands and place them securely in the center of the bench.

Step 2 of 9
Label your standard test tubes
- Place five clean, dry test tubes into your rack.
- Label them clearly with numbers 1, 2, 3, 4, and 5.
- Label one extra test tube 'Unknown'.
- Test tubes are seated firmly in the rack.
- Labels are positioned near the top of the tubes.
Careful: Tubes can roll off the table and shatter. Always keep test tubes upright in the rack.

Step 3 of 9
Mix the standard dilution tubes
- Add 0.40 M stock and water: Tube 1 (2/8 mL, 0.080 M), Tube 2 (4/6 mL, 0.16 M).
- Add: Tube 3 (6/4 mL, 0.24 M), Tube 4 (8/2 mL, 0.32 M), Tube 5 (~10/0 mL, 0.40 M).
- Mix each tube fully with a glass stirring rod.
- Check meniscus at eye level for each measurement.
- Keep the cylinders separated to prevent cross-contamination.
- Use cylinder A for blue copper solution and cylinder B for distilled water.
- Wipe the stir rod clean with a wipe between every tube.
Careful: If you swap cylinders, you change the solution concentrations. Label one cylinder 'Blue' and the other 'Water'.

Step 4 of 9
Connect your SpectroVis Plus
- Open the Spectral Analysis app on your tablet.
- Connect to your sensor over Bluetooth.
- Choose 'Absorbance vs. Concentration' from the experiment menu.
- Table is completely dry near the sensor.
- The sensor power light flashes.
- Press the power button to turn on the Go Direct SpectroVis Plus.
Careful: Liquid spilled onto the sensor can damage internal optics. Keep open beakers at least 30 cm away from the spectrophotometer.

Step 5 of 9
Prepare a pure water blank cuvette
- Fill a clean cuvette three quarters full with pure distilled water.
- Wipe the two smooth clear sides fully with a lint-free tissue.
- Gently tap the cuvette on the bench pad to release any air bubbles.
- Hands are gloved and dry.
- Lint-free tissue is ready.
- Hold the cuvette only by the ribbed top edges.
Careful: Fingerprints and bubbles scatter light. This gives false absorption readings. Never touch the clear lower sides. Wipe until the sides are clean.
4 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 11, Chemistry, chapter 1: Some Basic Concepts of Chemistry
- Related Class 12, Chemistry, chapter 4: The d- and f-Block Elements
- Related Class 12, Chemistry, chapter 5: Coordination Compounds
- Direct Level AS & A Level, Chemistry, chapter 3: Atoms, molecules and stoichiometry
- Related Level DP, Chemistry, chapter Structure 1.4: Counting particles by mass: The mole
Versions and what each needs
- Can light measure liquid strength? (spectrophotometer)
Advanced Chemistry, 50 min, Based on a Vernier lab
Needs: Go Direct SpectroVis Plus Spectrophotometer - Can light measure liquid strength? (colorimeter)
Advanced Chemistry, 60 min, Based on a Vernier lab
Needs: Go Direct Colorimeter
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.