Experiments › Physics
Can magnets make electricity?
Electromagnetic Induction in a Wire Coil
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 5 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can you generate real electricity without using any battery or wall outlet?
Show the answer
Yes! Moving a magnet near a coil of wire pushes electric charges into motion. Today you will catch that pulse and discover what makes it stronger.

Introduction
Power from Motion and Magnetism
Almost all the electricity powering your home comes from spinning magnets near copper coils. Giant turbines in hydroelectric dams, wind towers, and power stations work on this exact trick. When a magnet moves past a copper wire, its invisible magnetic field shoves electrons along the metal. In this lab, you drop a magnet through coils of wire and measure the electric pulse with a digital current sensor.
Driving question: Can moving a magnet through a loop of wire create an electric current without any battery?
What you will learn
Today you will find out
- I can show that only a moving magnet creates current in a wire coil.
- I can explain why the current graph swings positive and then negative.
- I can show that more turns of wire make a bigger current pulse.
- I can set up the current sensor and drop a magnet at a steady speed.
- I can explain how real-world generators use moving magnets to make electricity.
Why it matters: Every power plant on Earth uses this principle to produce the electricity running our cities, schools, and hospitals.
Safety first
Lab Rules for Electric Induction
- Wear safety goggles. Dropped magnets or sharp wire ends can snap or poke eyes.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Neodymium magnets are extremely strong. Keep them away from tablets, phones, credit cards, and fingers.
- Never drop heavy magnets onto bare tablet screens or glass benches.
- Do not connect wire coils to wall outlets or mains power. We only use small battery-safe sensor signals.
- Check that stripped wire ends are smooth and free of sharp burrs.
- Wash your hands after you touch bare copper wires.
What you need
- Go Direct Current Probe1 per group
- Tablet running Graphical Analysis1 per group
- wire solenoid coilSet of 5 coils (5, 10, 15, 30, 60 turns)
- bar magnets2 neodymium disk magnets taped to a marker dowel
- ring stand with clamp1 per group
- electrical wire with alligator clips2 wires (red and black)
- ruler1 plastic 30 cm ruler
- sandpaper sheet1 small strip fine-grit sandpaper · teacher
- safety goggles1 pair per person

Step 1 of 5 Teacher does this
Watch the galvanometer demonstration
- Watch your teacher connect a large wire coil to an analog galvanometer meter.
- Watch the needle closely as the teacher pushes a magnet into the coil.
- Notice what happens when the magnet stops inside, and when pulled back out.
- Everyone wears eye protection.
- Analog meter is positioned so the whole group can clearly see the needle.
Careful: Strong magnets that snap together suddenly can pinch fingers or chip brittle magnetic coatings. Hold magnets firmly. Keep them away from loose iron objects.

Step 2 of 5
Clamp the coil and prepare the drop height
- Clamp the 15-turn coil horizontally in the utility clamp on your ring stand.
- Position the coil about 15 cm above the tabletop so the magnet falls completely through.
- Use a ruler to place tape on the ring stand rod. Put it exactly 2.5 cm above the coil top to mark drop height.
- The ring stand base is stable and does not wobble.
- The utility clamp is snug so the coil does not slip.
- A soft cloth or foam pad on the table below catches the marker as it falls.
- Always drop the magnet from the exact 2.5 cm mark to make sure that it falls at the same speed every trial.
Careful: The magnet-marker can hit the table hard as it falls and crack or roll away. Place a soft cloth or mouse pad under the coil to cushion the impact.

Step 3 of 5
Connect the Go Direct Current Probe
- Clip the red lead of the current probe to one bare copper coil end.
- Clip the black lead of the current probe to the other bare copper end.
- Rest the probe flat on the bench so wires do not pull the coil.
- Both wire ends are shiny bare copper without a dark enamel layer.
- The alligator clips are attached firmly.
- Make sure the metal alligator clips bite firmly onto shiny, bare copper.
Careful: A clip over enamel varnish creates an open circuit with a zero current reading. Rub wire ends with fine sandpaper if they look dark or shiny reddish-brown.

Step 4 of 5
Drop the magnet and record your first pulse
- Have one teammate tap Collect in Graphical Analysis.
- Release the marker from the 2.5 cm mark straight down through the 15-turn coil center.
- Tap the peak on the screen to read the maximum current in milliamperes (mA).
- The magnet is vertical with the same pole toward the bottom on every trial.
- The marker tip aligns exactly with the 2.5 cm drop mark.
- Collector is ready to tap Collect right before release.
- Hold the magnet-marker vertically so its tip is exactly at the 2.5 cm mark above the 15-turn coil.
Careful: If you drop the marker before you tap Collect, the sensor can miss the brief 0.1-second pulse completely. Tap Collect first. Drop the marker immediately when the graph starts to update.

Step 5 of 5
Test coils with 5, 10, 15, 32, and 60 turns
- Do 3 drops from the 2.5 cm height for each coil. Test all 5 coils (5, 10, 15, 32, and 60 turns).
- Record the maximum peak current in milliamperes (mA) for every trial.
- Calculate the average peak current for each coil. Write it in your data table.
- Move alligator clips carefully when you change coils so you do not bend wire leads back and forth.
- The magnet is dropped from the exact same 2.5 cm height for every coil.
- Do drops from the same 2.5 cm height to make sure that results are reliable.
Careful: A change in drop height between coils introduces an uncontrolled speed variable. Double-check the 2.5 cm mark with your ruler before every single release.
0 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 10, Physics, chapter 9: Electromagnetism and Magnetic Effects and Electromagnetic Induction
Versions and what each needs
- Can magnets make electricity?
Physics Explorations, 50 min, Based on a Vernier lab
Needs: Go Direct 3-Axis Magnetic Field Sensor, Go Direct Current Probe, Go Direct Voltage Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.