Experiments › Chemistry

Can one drop change a liquid's colour?

Acid-Base Indicators and Neutralization

Grades 7-8Chemistry1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

A drinking glass of purple tea turning bright magenta where a drop of lemon juice touches the surface

Wonder

How can a single drop suddenly flip the colour of a liquid?

Show the answer

Special dyes called indicators change colour when acids and bases cancel each other out. Today you will track this turning point with a pH sensor!

Three test tubes with clear fluids displaying bright red, yellow, and blue colours next to a sliced lemon and soap bar

Introduction

The Secret Signal of Acids and Bases

When you drink lemonade, you taste acid. When you wash with soap, you use a base. But in a clear beaker, acids and bases look just like pure water! To tell them apart, chemists use special molecules called indicators that change colour when acidity shifts. When an acid and base completely cancel each other out, the mixture reaches a balance called the equivalence point. Today, you will use a Go Direct pH sensor and a Drop Counter to discover which indicator signals this turning point best.

Driving question: How do chemical indicators know the exact second an acid turns into a base?

What you will learn

Your Mission as a Chemist

  • I can tell when an indicator changes colour as pH changes.
  • I can explain what happens to pH during neutralization.
  • I can pick the best indicator for a strong acid-base reaction.
  • I can safely collect pH and drop data with Vernier sensors.
  • I can describe how pH indicators protect pools and crops.

Why it matters: Swimming pool technicians, soil farmers, and medicine makers rely on indicators every day to keep water clean, plants growing, and medicines safe.

Safety first

Laboratory Rules for Acids and Bases

  • Wear splash goggles, protective gloves, and a lab apron at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • 0.10 M Hydrochloric acid (HCl) and 0.10 M Sodium hydroxide (NaOH) can irritate skin and damage eyes.
  • Only your teacher pours, transfers, or empties stock acid and base solutions.
  • Never touch, taste, or sniff any chemical in the laboratory.
  • Keep all electrical sensors, cables, and tablets at least 30 cm away from liquid beakers.
  • Wash your hands fully with soap and warm water when lab cleanup is complete.

What you need

  • Go Direct pH Sensor1
  • Go Direct Drop Counter1
  • Vernier Stir Station and stir bar1
  • plastic 60 mL reagent reservoir1 · teacher
  • 0.1 M Hydrochloric acid solution25 mL · teacher
  • 0.10 M Sodium hydroxide solution70 mL · teacher
  • red or pink liquid in a reagent bottle3 dropper bottles
  • 100 mL beakers2
  • Distilled water wash bottle1
  • ring stand with clamp1 set
  • Tablet running Graphical Analysis1
Adult pipetting acid into a beaker and a student adding indicator drops

Step 1 of 8 Teacher does this

Adult prepares the acid sample

  1. An adult adds 40 mL of distilled water to a clean 100 mL beaker.
  2. Adult: use a graduated pipet. Carefully add 5.0 mL of 0.10 M HCl into the water.
  3. You add exactly two drops of bromthymol blue indicator into the beaker.
  4. Swirl gently. The liquid turns bright yellow because the solution is strongly acidic.
Stop and check
  • Everyone wears splash goggles and gloves.
  • The adult confirms the acid bottle is 0.10 M HCl.
  • Students stand one step back while acid is pipetted.

Careful: Splashes of hydrochloric acid can irritate skin or damage eyes. Always add acid into water, never water into acid. Wipe any droplets immediately.

Student sliding the drop counter onto the support rod above the stir station

Step 2 of 8

Assemble the Drop Counter and Stir Station

  1. Place the Stir Station on the table. Attach the vertical support rod.
  2. Slide the Go Direct Drop Counter onto the rod and tighten the clamp.
  3. Place the 100 mL beaker of yellow acid onto the Stir Station stage.
  4. Carefully drop a clean magnetic stir bar into the beaker.
Stop and check
  • Set the Stir Station to OFF before you position glassware.
  • The beaker sits flat and centred on the circular stage.

Careful: If you drop the stir bar too hard, it can crack the glass beaker. Tilt the beaker slightly and slide the stir bar down the inner glass wall gently.

Student guiding the pH sensor shaft through the drop counter into the beaker liquid

Step 3 of 8

Mount the pH sensor into the liquid

  1. Remove the storage bottle from the Go Direct pH Sensor. Rinse the glass bulb with distilled water.
  2. Insert the pH sensor shaft through the large round hole in the Drop Counter.
  3. Lower the sensor so its glass bulb is fully under the liquid.
  4. Make sure that the sensor bulb does NOT hit the stir bar while it spins.
Stop and check
  • Distilled water wash bottle is nearby.
  • pH storage cap is stored upright so buffer does not spill.

Careful: The stir bar can strike and shatter the delicate glass pH bulb while it spins. Position the probe tip close to the side wall, well away from the center while the bar spins.

Teacher pouring sodium hydroxide solution into the clear clamped reservoir

Step 4 of 8 Teacher does this

Set up the reagent reservoir

  1. Clamp the reservoir to the rod directly above the Drop Counter.
  2. The adult pours about 60 mL of 0.10 M NaOH base into the reservoir.
  3. Move the acid beaker aside, place an empty 250 mL waste beaker below, open valves briefly to fill tip, close them, and return acid.
Stop and check
  • Both valve handles are strictly horizontal (closed) before you add liquid.
  • A waste beaker is placed directly under the dispenser tip.
  • The adult wears splash goggles and purple nitrile gloves.
  • Both blue valves on the reagent reservoir are turned sideways (horizontal) to close them.

Careful: Sodium hydroxide can leak or splash if valves are left open. Double-check both valves are horizontal. Keep a paper towel underneath.

Student aligning the tip of the reservoir over the drop counter opening

Step 5 of 8

Start stirring and align the drops

  1. Turn on the Stir Station switch. Set the knob so the stir bar spins at a steady, gentle rate.
  2. Make sure that the reservoir tip aligns directly over the rectangular Drop Counter slot.
  3. Make sure that drops fall freely through the centre of the slot and do not touch the plastic edges.
  4. Tap Collect on the tablet. The app now waits for the first drop.
Stop and check
  • The stir bar spins smoothly and does not splash liquid against the walls.
  • Drop Counter red LED light blinks once when you tap the test button.

Careful: Drops will not register on the graph if they hit the plastic case instead of fall through the hole. Loosen the reservoir clamp slightly. Nudge the tip until it centres over the slot.

3 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Direct Class 11, Chemistry, chapter 6: Equilibrium

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.