Can plants power our cars?
Biofuels
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 9 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can plant stems and leftover grass run our cars?
Show the answer
Plants lock lots of energy inside tough stems. Natural helpers called enzymes chop them into sugar to make biofuels, and today you will test how they work.

Introduction
Plant Power: Slicing Molecules for Fuel
Fossil fuels take millions of years to form, but plants grow every season. Plant cell walls contain tough fibers called cellulose. If we can chop cellulose into sugar, yeast can brew it into clean ethanol fuel. Today, you will use a powerful enzyme called cellobiase. You will watch it chop molecules apart and turn yellow, then measure its speed with a spectrophotometer.
Driving question: Can biological scissors turn tough plant stems into clean burning fuel?
What you will learn
Today you will discover
- I can explain how an enzyme acts like scissors to break down plant molecules.
- I can test known standard solutions to build a reference graph.
- I can find an unknown liquid concentration using my standard curve line.
- I can calculate how much product an enzyme makes per minute.
- I can explain why biofuel factories need enzymes to make renewable fuel.
Why it matters: Biofuels help reduce carbon emissions by replacing fossil gasoline with renewable fuel made from agricultural waste.
Safety first
Laboratory Safety Rules
- Wear splash goggles, protective gloves, and a lab apron at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Stop solution is a basic chemical that can irritate eyes and skin. Handle with care.
- Never inhale enzyme powders or aerosols; cellobiase can trigger respiratory allergies.
- Keep all tubes and cuvettes upright in racks to prevent spills near electronics.
- Report any spills immediately to your teacher and rinse splashes with plenty of water.
- Wash your hands fully with soap and warm water when you finish.
What you need
- Go Direct SpectroVis Plus Spectrophotometer1 per lab group or station · teacher
- Plastic cuvette (4 clear sides)5 cuvettes with lids (4 standards + 1 reaction)
- p-nitrophenol standards set S1–S41 set (S1 blank, S2 12.5 uM, S3 25 uM, S4 50 uM)
- 1.5 mL microcentrifuge tube1 tube
- micropipette1 set (100–1000 µL and 20–200 µL with tip racks)
- 1X stop solution500 µL per reaction
- 1.5 mM substrate500 µL per reaction
- low concentration enzyme250 µL per reaction
- stopwatch1 digital stopwatch
- lint-free tissue1 box
- Splash goggles and nitrile gloves1 set per student

Step 1 of 9
Prepare the stop cuvette
- Take a clean, empty plastic cuvette.
- Pipet exactly 500 µL of 1X stop solution into this cuvette.
- Set the cuvette upright in your rack to stop the reaction later.
- Goggles and gloves are on properly.
- The cuvette is clean and rests in a stable rack.
- The micropipette is set to 500 µL with a fresh tip attached.
- Put on your safety goggles and gloves.
Careful: Stop solution is basic (pH 9.5) and can irritate skin or eyes if splashed. Pipette smoothly along the inside wall of the cuvette. Do not splash or squirt.

Step 2 of 9
Measure substrate into the reaction tube
- Take a clean 1.5 mL microcentrifuge tube and label it 'Reaction'.
- Use a fresh tip. Pipet 500 µL of 1.5 mM substrate into the tube.
- Place the tube in the microcentrifuge tube rack.
- A new, clean micropipette tip is attached.
- The microcentrifuge tube cap is popped open.
- Stopwatch displays 00:00.
- Make sure your stopwatch is reset to zero and ready to press.
Careful: If you reuse an old tip, you can contaminate the substrate before you add the enzyme. Always eject used tips into a waste beaker and use a fresh tip for every new liquid.

Step 3 of 9
Add enzyme and start the clock
- Use a clean tip. Pipet exactly 250 µL of low concentration enzyme into the substrate tube.
- Start the stopwatch the exact second the enzyme enters the tube!
- Close the cap. Flick the tube bottom 3 times to mix. Let it react.
- One partner watches the timer.
- The micropipette is set to 250 µL.
- Enzyme solution is ready.
- One teammate holds the stopwatch with their thumb on Start.
Careful: If you start the stopwatch late, your reaction rate calculation becomes inaccurate. Count down '3, 2, 1, GO' so your timer starts exactly when you dispense the liquid.

Step 4 of 9
Stop the reaction at 2 minutes
- At exactly 2 minutes, pipet 500 µL from the reaction tube into your stop cuvette.
- Pipet up and down gently once to mix.
- Observe the yellow color as the basic stop solution halts the enzyme.
- Stop cuvette prepared in Step 1 is open and nearby.
- Timer reads around 1 minute 50 seconds.
- Micropipette is set to 500 µL.
- Watch the stopwatch closely as it approaches 2 minutes (120 seconds).
Careful: If you transfer too early or too late, you skew the calculated product formation rate. Draw 500 µL at 1:58 and dispense into the stop cuvette right as the clock hits 2:00.

Step 5 of 9 Teacher does this
Power and connect the SpectroVis Plus
- Turn on your Go Direct SpectroVis Plus spectrophotometer.
- Connect the spectrophotometer with Bluetooth.
- Choose 'Absorbance vs. Concentration' mode in the app.
- The spectrophotometer rests on a dry, level table.
- Reagents and open liquids are placed safely away from the tablet.
- SpectroVis power button is pressed and LED is on.
- Start Vernier Spectral Analysis on your tablet or computer.
- When the sensor connects, its indicator light flashes green.
Careful: Liquids spilled into the cuvette chamber can damage the optical lenses and electronics. Wipe the outside of every cuvette completely dry before you insert it into the sensor slot.
4 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Level DP, Biology, chapter B1.1: Carbohydrates and lipids
Versions and what each needs
- Can plants power our cars?
Investigating Biology, 80 min, Based on a Vernier lab
Needs: Go Direct SpectroVis Plus Spectrophotometer
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.