Experiments › Chemistry

Can sharp liquids make fruit scent?

Synthesizing Ethyl Acetate

Grades 7-8Chemistry1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

A sliced ripe yellow pear beside a small glass fragrance bottle on a wooden table

Wonder

Can two sharp-smelling liquids turn into a sweet fruity scent?

Show the answer

Warming sharp vinegar acid with alcohol joins them into a sweet fruit aroma. Scientists call these sweet molecules esters, and today you will make one and track how it forms.

Assortment of fruity sweets and scented oils on a wooden surface

Introduction

The Science of Sweet Scents

Have you ever smelled artificial apple sweets, banana gum, or fruity perfumes? Those fragrances are rarely squeezed from actual fruit. Instead, chemists build molecules called esters in the lab. Today, your class combines sharp-smelling acetic acid with alcohol. As they warm up, a new sweet molecule forms: ethyl acetate! You will use a high-tech gas chromatograph to watch this new molecule appear over time.

Driving question: Can you combine vinegar acid and alcohol to create a sweet fruity fragrance?

What you will learn

Today you will discover

  • I can explain how an ester is made from alcohol and acid.
  • I can identify peaks on a chromatogram using their retention time.
  • I can show how heating longer produces more ester product.
  • I can follow safety steps when observing heating and chemical tests.
  • I can name everyday products made using synthetic esters.

Why it matters: Flavor chemists, perfume makers, and medicine manufacturers rely on ester reactions and gas chromatography every day.

Safety first

Essential Safety Rules for This Lab

  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Glacial acetic acid causes severe chemical burns and harsh vapors: handled only by the teacher in a fume hood.
  • The 1 µL syringe has an extremely sharp, delicate steel needle: handled only by the teacher.
  • Water bath reaches 70°C and hot plate surfaces can burn skin: observe from a safe distance.
  • Always leave a vent pinhole or loose cork in heated tubes so pressure does not build up.
  • Wear chemical splash goggles and gloves during the entire experiment.

What you need

  • Go Direct Mini GC1 per station · teacher
  • Go Direct Wide Range Temperature1 per station
  • Tablet running Graphical Analysis1 per group
  • microliter syringe1 (1 µL precision) · teacher
  • test tubes, 25 × 200 mm3 tubes and rack
  • 250 mL beakers2 beakers
  • laboratory hot plate1 hot plate · teacher
  • Dowex 50 × 2 ion exchange resinsmall vial with spatula
  • clear solution in a reagent bottleEthanol, acetic acid, ethyl acetate vials · teacher
  • Splash goggles and nitrile gloves1 set per person
Teacher configuring the Mini GC software on a tablet

Step 1 of 7 Teacher does this

Set up the Mini GC profile

  1. An adult turns on the Go Direct Mini GC and connects it to the tablet.
  2. In Instrumental Analysis, set the start temperature to 35°C for 1 minute. Ramp 5°C per minute to 65°C for 5 minutes.
  3. Set column pressure to 10 kPa. Wait until the LED glows solid green.
Stop and check
  • On a stable table, the Mini GC connects to electrical power.
  • Ventilation around the unit is completely clear.
  • Students keep a safe distance from power cables.

Careful: The internal column heats up. Damaged power cords can cause an electrical hazard. Only the adult connects power and sets column temperature and pressure.

Teacher injecting sample into the Mini GC injection port

Step 2 of 7 Teacher does this

Inject pure standards into the Mini GC

  1. An adult cleans the 1 µL syringe with acetone three times.
  2. Draw 0.3 µL of pure ethanol, guide the needle into the port, inject, and start collection.
  3. Repeat the injection for pure ethyl acetate, then pure acetic acid.
Stop and check
  • Glacial acetic acid is kept inside the fume hood.
  • The adult wears eye goggles and purple nitrile gloves.
  • Only the adult handles the sharp glass microliter syringe.
  • Note each substance's retention time peak: ethanol (~1.5 min), ester (~2.3 min), acid (~4.1 min).

Careful: The delicate syringe needle can bend or puncture skin. Acetic acid fumes cause eye irritation. Push the plunger straight down smoothly. Do not use force. Never bend the needle.

A beaker of warm water with temperature probe on a hot plate next to an ice bath

Step 3 of 7 Teacher does this

Prepare warm water and ice quench baths

  1. Pour 120 mL of water into a 250 mL beaker. Place the beaker on the hot plate. Insert the Go Direct Wide Range Temperature probe.
  2. An adult turns on the hot plate to warm the water to 65 to 70°C.
  3. Fill a second 250 mL beaker with cold water and ice cubes to quench the reaction.
Stop and check
  • Hot plate cord is safely tucked away.
  • The temperature probe rests securely in the beaker.
  • The ice bath sits nearby on a stable tray.

Careful: Hot water and hot plate surfaces can cause burns if touched or knocked over. Keep hands away from the hot plate surface. Adjust the heat dial carefully.

Three labelled test tubes with resin beads and liquid being capped with Parafilm

Step 4 of 7 Teacher does this

Prepare three reaction test tubes

  1. Label three large test tubes 1, 2, and 3. Place them in the rack.
  2. Use a clean spatula to add a small pinch of Dowex resin beads to barely cover each bottom.
  3. An adult adds 1 mL (25 drops) ethanol and 1 mL acetic acid with plastic Beral pipettes, covers each with Parafilm, and pokes a pinhole.
Stop and check
  • Students wear blue nitrile gloves and goggles.
  • The adult dispenses the glacial acetic acid inside the fume hood.
  • Each tube has a pinhole to release pressure.
  • Caution: Use a pin to poke one small pressure release hole in each tube's Parafilm seal.

Careful: Unvented tubes can pop their caps or shatter from vapor pressure when heated. Always poke a pinhole in the film or keep the cork loose before you heat the tube.

Adult using a clamp to transfer a hot test tube into an ice water bath

Step 5 of 7 Teacher does this

Start reaction and quench Tube 1 at 20 min

  1. An adult lowers all three test tubes into the warm 65 to 70°C water bath together. Start the stopwatch immediately.
  2. At exactly 20 minutes, an adult removes Tube 1 with a test tube clamp.
  3. Place Tube 1 into the ice water quench bath for 2 minutes to halt the reaction.
Stop and check
  • Test tubes are securely positioned in the water bath.
  • The stopwatch counts up from zero.
  • The ice quench bath is within easy reach.
  • Keep the water bath at 65 to 70°C throughout the reaction.

Careful: Tubes get very hot and can burn bare skin or splash hot water if dropped. Always use a wooden or metal test tube clamp to transfer tubes to the ice bath.

2 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Direct Class 10, Science, chapter 4: Carbon and its Compounds
Cambridge AS & A Level
  • Direct Level AS & A Level, Chemistry, chapter 17: Alcohols, esters and carboxylic acids

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.