Experiments › Chemistry

Can two liquids turn off electricity?

Conductivity Eq Point

Grades 7-8Chemistry1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

Two clear drinking glasses and a small glowing battery circuit on a wooden table in sunlight

Wonder

Can mixing two liquids that carry electricity make the current stop completely?

Show the answer

Both liquids let electricity flow on their own. When mixed, their charged particles lock into solid powder and pure water, stopping the current. Scientists call this the turning point, and today you will measure it.

A clear drinking glass of water and mineral water on a sunlit wooden table

Introduction

Can Two Conductive Liquids Cancel Each Other Out?

Pure water does not carry electricity, but water with dissolved minerals carries electric current with ease. Charged particles called ions let the current flow. What happens when you mix two liquids whose ions lock together into a solid powder? You will measure electrical conductivity and discover the hidden turning point where electricity suddenly stops flowing.

Driving question: Can two liquids that conduct electricity cancel each other out so electricity stops flowing?

What you will learn

Your Mission Today

  • I can explain why some liquids conduct electricity and others do not.
  • I can observe the conductivity drop as two liquids cancel each other out.
  • I can find the turning point from the lowest point on a V-shaped graph.
  • I can measure liquid volumes with a buret while tracking sensor data.
  • I can describe how water treatment plants use conductivity to detect dissolved salts.

Why it matters: Water purification plants, kidney dialysis machines, and chemical factories all use conductivity sensors to detect dissolved chemicals without tasting or touching them.

Safety first

Laboratory Safety Rules

  • Wear safety goggles, nitrile gloves, and a lab apron at all times.
  • Sulfuric acid and barium hydroxide irritate skin and eyes.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Look for the ADULT NEEDED badge. An adult must fill the buret and handle the acid stock.
  • Never taste or touch lab chemicals, and keep liquids 30 cm away from laptops and tablets.
  • Wash your hands fully with soap and water after the experiment.

What you need

  • Go Direct Conductivity Probe1
  • Stir Station1
  • Electrode Support1
  • buret1 (50 mL) · teacher
  • buret clamp1
  • 250 mL beaker2
  • 100 mL graduated cylinder1
  • magnetic stir bar1
  • clear solution in a reagent bottle60 mL (~0.02 M H2SO4) · teacher
  • clear solution in a reagent bottle50 mL (~0.006 M Ba(OH)2)
  • Distilled water wash bottle1 bottle (200 mL)
  • Tablet running Graphical Analysis1
Adult pouring acid through a funnel into the top of a buret

Step 1 of 7 Teacher does this

Adult fills and prepares the buret

  1. An adult clamps the clean 50 mL buret to the Stir Station rod.
  2. The adult uses a small funnel to pour about 50 mL of 0.020 M sulfuric acid into the buret.
  3. The adult drains a few drops into a waste beaker to fill the tip completely. The adult sets the liquid level to 0.00 mL.
Stop and check
  • The adult wears safety goggles and purple nitrile gloves.
  • The buret stopcock is closed (horizontal) before you pour.
  • Waste beaker is placed beneath the buret tip.

Careful: Acid can spill over the top rim or splash into eyes if poured quickly. Pour at eye level with a funnel. Make sure students stand back.

Student pouring barium hydroxide into a 250 mL beaker

Step 2 of 7

Prepare the barium hydroxide beaker

  1. Pour 50.0 mL of barium hydroxide solution from a clean 100 mL cylinder into your 250 mL beaker.
  2. Use the cylinder to add 120 mL of distilled water to the beaker.
  3. Gently drop the white magnetic stir bar into the beaker.
Stop and check
  • Wear goggles and light blue nitrile gloves.
  • Pour slowly on the lab bench so the liquid does not splash.
  • Check the graduated cylinder reading at eye level.

Careful: If you drop the stir bar too hard, you can crack the glass beaker base. Tilt the beaker slightly and slide the stir bar down the side gently.

Conductivity Probe lowered into beaker on Stir Station beside the buret tip

Step 3 of 7

Assemble the probe, beaker, and Stir Station

  1. Place the beaker onto the center of the Stir Station platform.
  2. Slide the Go Direct Conductivity Probe into the Electrode Support arm.
  3. Lower the probe into the beaker until liquid fully covers the hole near the probe tip.
Stop and check
  • Stir Station is plugged in and turned off for now.
  • Electrode Support is clamped tightly to the metal rod.
  • The probe end is at least 5 mm above the bottom of the beaker.
  • Make sure the probe sits safely to one side so the stir bar will not hit it.

Careful: The magnetic stir bar can strike the carbon electrodes and damage the probe. Position the probe near the edge of the beaker, away from the central vortex.

Student tapping Keep Point on tablet with setup stirring beside it

Step 4 of 7

Record the starting point (0.0 mL)

  1. Turn on the Stir Station so the solution stirs at a steady, medium speed.
  2. Tap Collect in Graphical Analysis.
  3. Tap Keep. Type 0 for the volume. Tap Keep Point to save your first data pair.
Stop and check
  • The stir motion is smooth and no bubbles hit the probe end.
  • The buret liquid level is still at exactly 0.00 mL.
  • Goggles and gloves are on.
  • Before you open the buret, wait for the conductivity reading to stabilize (about 900 to 1000 µS/cm).

Careful: If you save data before the probe stabilizes, you store an inaccurate initial conductivity. Watch the digital readout for 5 seconds until the number changes by less than 2 µS/cm.

Student pinching the blue buret stopcock while acid drips into the stirring beaker

Step 5 of 7

Add 1.0 mL increments of acid

  1. Carefully turn the blue buret stopcock to add 1.0 mL of sulfuric acid into the beaker.
  2. Wait 5 seconds for the reading to stabilize. Tap Keep. Type the new buret volume (e.g. 1.0). Tap Keep Point.
  3. Repeat in 1.0 mL additions until conductivity drops below 100 µS/cm.
Stop and check
  • One student controls the buret tap carefully.
  • One student reads the buret mark at eye level.
  • One student types the volume on the tablet.

Careful: If you open the buret tap too far, acid rushes past the mark. Grip the blue valve handle firmly with your thumb and forefinger and twist slowly.

2 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Direct Class 9, Science, chapter 3: Atoms and Molecules
  • Direct Class 10, Science, chapter 1: Chemical Reactions and Equations
ICSE (CISCE)
  • Related Class 10, Chemistry, chapter 4: Analytical Chemistry
  • Direct Class 10, Chemistry, chapter 10: Sulphuric Acid
Cambridge AS & A Level
  • Direct Level AS & A Level, Chemistry, chapter 3: Atoms, molecules and stoichiometry

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.