Can water carry electricity?

Electrical Conductivity of Solutions

Grades 7-8Physical Science & Chemistry4 versions

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

An empty outdoor swimming pool under dark stormy clouds with distant lightning

Wonder

Why is swimming in a thunderstorm dangerous if pure water cannot conduct electricity?

Show the answer

Pure water does not carry electricity easily, but dissolved minerals let current flow right through. Scientists call this electrical conductivity, and today you will measure it.

A clear drinking glass of water on a kitchen table beside an ordinary salt shaker

Introduction

The Secret Movers in Water

You have probably been told never to drop an electrical hairdryer into bathwater. Yet surprisingly, pure water does not carry electrical current. So what makes everyday water conduct? It is not the water itself: it is what is dissolved inside it! When salts dissolve, they split into charged particles called ions that act like tiny ferry boats carrying electrical current. Today, you will use a digital conductivity probe to test different liquids and discover what lets electricity flow.

Driving question: Why does pure water refuse to conduct electricity, while adding a pinch of salt turns it into a conductor?

What you will learn

Today you will find out

  • I can explain why some dissolved substances conduct electricity while others do not.
  • I can measure electrical conductivity in µS/cm using a digital sensor.
  • I can explain why compounds releasing more ions produce higher conductivity.
  • I can properly rinse and dry the conductivity probe between different samples.
  • I can name real-world jobs that rely on measuring electrical conductivity.

Why it matters: Farmers test soil runoff, drinking water plants monitor purity, and doctors check electrolyte balance in blood using conductivity.

Safety first

Laboratory Safety Rules

  • Wear safety goggles and protective lab gloves at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Never taste any lab liquid, even if the label says salt, sugar, or water.
  • Some test solutions (like ethanol) are flammable: keep all beakers away from open flames and hot plates.
  • Keep liquids at least 30 cm away from your tablet or laptop.
  • Rinse the probe gently with distilled water over the waste beaker; do not splash.

What you need

  • Go Direct Conductivity Probe1 per group
  • ring stand with clamp1 per group
  • Tablet running Graphical Analysis1 per group
  • Distilled water wash bottle1 per group
  • 250 mL beaker1 per group (for waste rinse)
  • 50 mL beaker8 to 10 small beakers or jars
  • clear solution in a reagent bottle1 set of test solutions (NaCl, CaCl2, AlCl3, ethanol, sucrose, glucose, tap water)
  • tissue wipes1 box per group
  • Splash goggles and nitrile gloves1 set per student
A student hand clamping the conductivity probe onto a ring stand

Step 1 of 7

Clamp the conductivity probe to the stand

  1. Attach the utility clamp securely to the ring stand post.
  2. Gently clamp the upper plastic barrel of the Go Direct Conductivity Probe.
  3. Position the probe so the bottom tip hangs about 3 cm above the metal base.
Stop and check
  • The ring stand base sits flat and stable on the table.
  • The utility clamp thumbscrews are firmly tightened.
  • The probe is gripped by its upper barrel, not by its sensitive lower shaft.
  • Make sure the clamp is snug, but do not overtighten and crack the plastic body.

Careful: The probe could slip out of an unfastened clamp and hit the tabletop. Support the probe with one hand while you tighten the clamp screw with the other.

Student finger pressing the power button on the conductivity probe

Step 2 of 7

Power on and pair your probe

  1. Press the power button once on the Go Direct Conductivity Probe.
  2. Open the Graphical Analysis app on your tablet or computer.
  3. Tap 'Sensor Data Collection'. Select your probe from the list.
Stop and check
  • Tablet Bluetooth is turned on.
  • The probe has sufficient battery charge.
  • Keep drinks and open water away from the tablet screen.
  • Check that the status light on the probe blinks green. This shows that the probe is connected.

Careful: You connect to another group's probe by mistake. Match the serial number printed on your probe's label with the device name on the screen.

Student rinsing the conductivity probe with a distilled water bottle over a waste beaker

Step 3 of 7

Rinse and blot the probe

  1. Place an empty 250 mL waste beaker beneath the probe tip.
  2. Squirt distilled water from the wash bottle over the shaft and electrode slot.
  3. Blot the OUTSIDE of the shaft dry with a clean tissue.
Stop and check
  • Use only pure distilled water, never tap water.
  • The waste beaker is positioned directly below to catch drips.
  • Use soft wipes, not rough abrasive cloth.
  • Let the excess water drip into the waste beaker.
  • Do not poke paper inside the electrode hole.

Careful: Rolled paper towels inside the slot can scratch the graphite electrodes. Only blot the smooth outside plastic case. Leave the inside moist with pure water.

Student holding a small beaker up to immerse the probe tip in distilled water

Step 4 of 7

Test pure distilled water

  1. Pour about 40 mL of distilled water into a clean 50 mL beaker.
  2. Raise the beaker upward around the probe until the liquid fully covers the bottom hole.
  3. Record the reading in your data table once the number stops.
Stop and check
  • The beaker contains clean distilled water.
  • The rectangular slot near the probe tip is fully under water.
  • Hands are gloved and dry.
  • Swirl the beaker gently once to release any trapped air bubbles from the electrode slot.

Careful: Trapped air bubbles inside the electrode hole block electrical contact and give false low numbers. Swirl the beaker gently around the probe to remove any air bubbles.

Student testing sugar solution and tablet showing 0 µS/cm

Step 5 of 7

Test molecular solutions: sugar and ethanol

  1. Immerse the probe into the sucrose (table sugar) solution and record the stable reading.
  2. Rinse the probe. Blot the probe dry. Test the glucose (corn sugar) solution. Record the reading.
  3. Rinse the probe. Blot the probe dry. Test the ethanol solution. Record your value.
Stop and check
  • Ethanol solution is flammable: keep away from heaters and sparks.
  • Rinse with distilled water between every single test.
  • Blot the outside of the probe dry before you put it into the next beaker.
  • Rinse the probe fully with distilled water and blot the outside dry before you start.

Careful: Ethanol is an alcohol and slightly flammable; fumes should not be inhaled deeply. Keep beakers covered when not in use. Work in a well-ventilated laboratory.

2 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Direct Class 8, Science, chapter 8: Nature of Matter: Elements, Compounds, and Mixtures
  • Direct Class 8, Science, chapter 11: Chemical Effects of Electric Current
  • Direct Class 10, Science, chapter 2: Acids, Bases and Salts
ICSE (CISCE)
  • Related Class 10, Chemistry, chapter 6: Electrolysis
Cambridge AS & A Level
  • Direct Level AS & A Level, Chemistry, chapter 4: Chemical bonding
  • Related Level AS & A Level, Chemistry, chapter 5: States of matter
IB Diploma
  • Direct Level DP, Biology, chapter A1.1: Water
  • Direct Level DP, Biology, chapter D2.3: Water potential

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.