Experiments › Biology

Can yeast adapt to a new food?

Yeast Evolution

Grades 7-8Biology1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

A loaf of freshly baked crusty bread cut open showing fluffy air pockets inside

Wonder

Why does bread dough puff up and fill with airy pockets?

Show the answer

Millions of microscopic yeast cells eat sugar and exhale carbon dioxide gas. Today you will catch their breath in real time!

A glass bowl of dough rising with visible yeast bubbles under warm light

Introduction

The Living Bubbles in Your Bread

When you bite into soft bread, you are tasting the work of microscopic fungi. Baker's yeast cells eat sugars and produce carbon dioxide gas. The trapped gas bubbles make the dough rise before baking. But how fast do these tiny living cells actually breathe? Today, you will put yeast into a warm bath, feed it sugar, and track its breathing using a digital gas sensor.

Driving question: How quickly do tiny living yeast cells breathe out gas when they feast on sugar?

What you will learn

Today you will find out

  • I can explain how yeast produces carbon dioxide gas from sugar.
  • I can keep a water bath at a steady temperature for living cells.
  • I can use a gas sensor to track carbon dioxide changes over time.
  • I can find how fast yeast breathes by reading the graph slope.
  • I can relate yeast gas production to real-world baking and selective breeding.

Why it matters: Bakers, food scientists, and biofuel engineers rely on yeast respiration every single day. Understanding yeast metabolism helps us produce food and renewable energy.

Safety first

Scientist Rules for Today

  • Wear safety goggles, lab gloves, and an apron when you handle liquids.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Treat all lab solutions with care. Never taste or drink yeast or glucose mixes.
  • Handle warm water carefully so you do not splash your skin or clothes.
  • Keep all water and liquids away from the tablet and sensor electronics.
  • Wash your hands fully with soap and water after you clean up.

What you need

  • Go Direct CO2 Gas Sensor1
  • Go Direct Temperature Probe1
  • Sampling Chamber (250 mL / 2 L)1 (250 mL Nalgene bottle)
  • 1 L beaker1 (1000 mL)
  • ring stand with clamp1 stand with 2 utility clamps
  • 15 mL centrifuge tube1 with screw cap
  • Plastic Beral pipets2
  • plastic syringe1 (10 to 20 mL)
  • clear solution in a reagent bottle10 mL (0.30 M glucose solution)
  • cloudy biological liquid10 mL baker's yeast suspension (from stirred beaker)
  • Tablet running Graphical Analysis1
  • paper towel3 to 4 sheets
Student hand pairing the CO2 sensor and temperature probe to a tablet

Step 1 of 7

Connect your sensors

  1. Turn on the Go Direct CO2 Gas Sensor and the Go Direct Temperature Probe.
  2. Open Vernier Graphical Analysis on your tablet or laptop.
  3. Connect both sensors with Bluetooth.
Stop and check
  • Both sensors are charged.
  • The tablet is placed away from any open water.
  • Hands are clean and dry.
  • If your CO2 sensor has a physical switch, set it to the Low (0–10,000 ppm) position.

Careful: Wrong range switch setting makes the gas reading go off-scale or inaccurate. Make sure that the physical switch on the CO2 sensor is at Low (0–10,000 ppm).

1000 mL beaker on ring stand base with temperature probe clamped in water

Step 2 of 7

Prepare the warm water bath

  1. Fill the 1000 mL beaker with about 600 mL of water.
  2. Mix warm and cool water until the Temperature Probe reads 29°C to 31°C.
  3. Clamp the Temperature Probe so its metal tip sits in the water.
Stop and check
  • The beaker sits flat and sturdy on the stand base.
  • The water level is near the 600 mL line.
  • The tip of the temperature probe is submerged and does not touch the glass bottom.
  • Place the beaker onto the heavy base of the ring stand.
  • Keep a syringe handy to swap in warm water if the temperature begins to drop.

Careful: Water hotter than 35°C can stress or kill the yeast cells before data collection begins. Add warm water gradually in small splashes until the temperature settles between 29°C and 31°C.

Student hand pipetting cloudy yeast suspension from a stirring beaker into a conical tube

Step 3 of 7

Measure glucose and active yeast

  1. Use a clean Beral pipet to transfer exactly 3.0 mL of glucose solution into the 15 mL conical tube.
  2. Draw 3.0 mL of yeast from the middle of the stirred stock into the tube. This brings the total volume to 6.0 mL.
  3. Screw the blue cap on tightly. Invert the tube 3 times to mix fully.
Stop and check
  • The two pipets are kept separate: one for glucose, one for yeast.
  • The yeast stock spins on the magnetic stirrer.
  • You sample from the middle of the beaker, not the top foam.
  • Walk to the yeast station where the stock beaker stirs continuously.
  • Use a second clean pipet to draw 3.0 mL of yeast from the middle of the stirred liquid.

Careful: If you take yeast that is not stirred, you get too few cells. This causes very low respiration rates. Only take yeast while the magnetic stir bar turns the liquid.

Student hands pressing the CO2 sensor shaft into the mouth of the plastic bottle

Step 4 of 7

Seal the respiration chamber

  1. Uncap the conical tube and pour the entire 6.0 mL mixture into the dry 250 mL plastic chamber.
  2. Pick up the Go Direct CO2 Gas Sensor.
  3. Push the sensor shaft firmly into the chamber neck with a gentle twist.
Stop and check
  • The chamber was completely dry before you poured the liquid.
  • The liquid rests at the bottom of the bottle.
  • The sensor shaft enters straight and does not jam.
  • Make sure the fit is snug so no gas can leak out around the rubber stopper collar.

Careful: A loose sensor lets carbon dioxide escape into the room. This ruins the rate measurement. Use a firm, gentle twist until the sensor stopper sits tight in the bottle mouth.

Respiration bottle submerged in water bath and clamped to ring stand matching Figure 1

Step 5 of 7

Submerge the chamber and clamp in place

  1. Lower the sealed plastic bottle into the warm 30°C water bath.
  2. Use the second utility clamp on the ring stand to grip the neck of the bottle securely.
  3. Position the Temperature Probe back into the water bath beside the chamber.
Stop and check
  • The beaker does not tip over when you clamp it.
  • The clamp grips the bottle neck, not the electronic sensor head.
  • The sensor top stays completely above the water surface.
  • Temporarily raise or shift the Temperature Probe so there is room inside the beaker.
  • Make sure the bottle sits upright and the bottom liquid is fully submerged in the warm water.

Careful: Water in the electronic top of the CO2 sensor will short-circuit the device. Keep water well below the top rim of the bottle; never submerge the sensor body.

2 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 12, Biology, chapter 6: Evolution
IB Diploma
  • Direct Level DP, Biology, chapter A4.1: Evolution and speciation
  • Direct Level DP, Biology, chapter B4.1: Adaptation to environment
  • Direct Level DP, Biology, chapter B4.2: Ecological niches
  • Direct Level DP, Biology, chapter C1.2: Cell respiration
  • Direct Level DP, Biology, chapter D4.1: Natural selection

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.