Experiments › Chemistry

Can you build a sandwich molecule?

Friedel Crafts Acylation Ferrocene

Grades 7-8Chemistry1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 10 steps. To run it with the sensors, record data and take the quiz, students use the app.

Artistic rendering of a ferrocene sandwich molecule changing colour from yellow to orange

Wonder

Can you trap an iron atom inside a tiny chemical sandwich?

Show the answer

Yes! Ferrocene is an iron atom trapped between two carbon rings. Today we snap a new chemical group onto it, watch the colour transform from yellow to orange, separate the mixed colours in a glass column, and test the new crystals!

Laboratory setup showing colourful test tubes and molecular building blocks

Introduction

Can You Build a Sandwich Molecule?

Imagine building with chemical Lego bricks. Some molecules are shaped like sandwiches with metal in the middle! Ferrocene is a famous sandwich molecule with an iron atom in the centre. In this lab, we attach a new chemical piece onto the sandwich. This reaction transforms bright yellow crystals into deep orange crystals. How do we separate the new molecule from leftover starting pieces? We use a glass column packed with powdery silica sand. Different colours race down at different speeds. Then, we use high-tech Vernier sensors to test their light absorption and measure their exact melting temperatures!

Driving question: How can scientists change the shape of a molecule and prove what they made?

What you will learn

Goals for this activity

  • I can explain how a reaction changes the colour and structure of a molecule.
  • I can explain how a silica column separates mixed colours.
  • I can identify compounds by their light absorption graph.
  • I can use melting temperature to tell two pure solids apart.
  • I can follow safety rules around strong acids, organic solvents, and hot equipment.

Why it matters: Pharmaceutical scientists build new medicines by modifying molecules and separating pure products from reaction mixtures every day.

Safety first

Safety Rules for Organic Chemistry

  • Always wear safety goggles, gloves, and a buttoned lab coat.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • All strong acids, acetic anhydride, and hexane solvents stay inside the fume hood.
  • Never breathe chemical fumes, and never taste anything in the lab.
  • Capillary tubes consist of thin glass. Handle them gently to avoid cuts.
  • The Go Direct Melt Station gets hot enough to burn skin. Keep hands off the metal heat block.

What you need

  • Go Direct Melt Station1 per group
  • Go Direct SpectroVis Plus Spectrophotometer1 per group
  • Go Direct Wide Range Temperature1 per station
  • glass capillary melting tubes4 tubes per group
  • Plastic cuvette (4 clear sides)2 cuvettes with lids
  • 10 mL disposable serological pipet, glass1 pipet
  • Reagents (ferrocene, acetic anhydride, 85% phosphoric acid, hexane, silica gel)Prepared in fume hood · teacher
  • mortar and pestle1 small set
  • Test tubes and rack1 rack with 4 test tubes
Teacher adding acid drops to a flask in the fume hood

Step 1 of 10 Teacher does this

Teacher mixes the reactants

  1. Inside the fume hood, the teacher weighs 1.0 g acetic anhydride into a 50 mL flask. The teacher adds 0.25 g yellow ferrocene.
  2. Drop a tiny magnetic stir bar inside.
  3. The teacher carefully adds 8 drops of 85% phosphoric acid while you stir.
  4. Watch closely: the yellow powder dissolves and begins to turn dark red-orange!
Stop and check
  • Fume hood sash is lowered to the safe mark.
  • The teacher wears goggles, a lab coat, and chemical gloves.
  • Students stand outside the fume hood perimeter.

Careful: Phosphoric acid and acetic anhydride cause painful chemical burns. The reaction releases heat. Only the teacher dispenses these chemicals. Keep the fume hood sash lowered.

Reaction flask warming in a water bath with temperature probe

Step 2 of 10 Teacher does this

Warm the reaction flask

  1. The teacher clamps the flask in a 65 °C warm water bath for 10 minutes.
  2. A Go Direct Wide Range Temperature Probe monitors the bath temperature.
  3. Heat speeds up the reaction so the new acetyl piece bonds to the iron sandwich.
  4. After 10 minutes, the teacher pours the liquid over ice in a beaker.
Stop and check
  • The water bath stays near 65 °C and does not boil.
  • Flask is clamped securely so it cannot tip over.

Careful: Hot water or chemical splashes can cause burns. Use beaker tongs or clamp stands. Keep faces away from steam.

Orange precipitate filtering on vacuum filter paper

Step 3 of 10 Teacher does this

Neutralise and collect crude crystals

  1. Add solid sodium bicarbonate to the cold mixture until bubbles stop.
  2. The acid is now neutralised and turns into harmless water and carbon dioxide gas.
  3. Bright orange solid bits form in the ice water.
  4. The teacher pours the mixture through vacuum filter paper to trap the crude solid.
Stop and check
  • Add bicarbonate in small pinches so bubbles do not foam over.
  • Check with pH paper to confirm neutral.

Careful: Rapid foam can spill liquid over the counter. Add pea-sized amounts slowly until bubbles stop.

Student packing cotton, sand, and silica into a glass pipet column

Step 4 of 10

Pack the chromatography column

  1. Take a clean 10 mL glass pipet clamped vertically on a ring stand.
  2. Gently push a tiny cotton plug to the bottom with a thin rod.
  3. Pour in 0.5 cm of clean sand, followed by white silica powder up to two-thirds full.
  4. Add 0.5 cm of sand on top. Tap gently so the silica packs firmly without gaps.
Stop and check
  • Pour silica powder inside the fume hood so you do not breathe dust.
  • Wear gloves and goggles.

Careful: Silica dust irritates lungs if you breathe it. A loose pack ruins the separation bands. Handle silica powder in the hood; tap the glass gently to settle the powder evenly.

Dropper adding concentrated orange sample onto the top of the column

Step 5 of 10 Teacher does this

Load the crude sample onto the column

  1. The teacher dissolves a tiny pinch of the crude solid in a few drops of ether.
  2. Wash hexane solvent through the column to wet the silica evenly.
  3. With a long dropper, the teacher carefully adds the dissolved sample to the top sand layer.
  4. A narrow, dark ring forms at the top of the white silica.
Stop and check
  • Solvent additions happen in the fume hood.
  • Never let the liquid level drain below the top of the silica.

Careful: If the column dries out, the silica cracks and colours mix. Add liquid solvent continuously before the top layer goes dry.

5 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 11, Chemistry, chapter 3: Hydrocarbons
Cambridge AS & A Level
  • Related Level AS & A Level, Chemistry, chapter 25: Benzene and its compounds

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.