Experiments › Human Physiology
Can you calm your heart?
Biofeedback
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 9 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can you slow your pounding heart just by thinking calm thoughts?
Show the answer
When ice-cold water touches your foot, your body sounds a stress alarm. Biofeedback lets you watch that alarm on screen and learn to quiet it down with your mind.

Introduction
Can You Calm Your Heart?
Picture stepping into freezing cold snow barefoot. Instantly, your body gasps and your pulse leaps! That is your body's automatic alarm system. Usually, you cannot feel your exact heartbeat speed. But what if a screen showed your heart and breath live in real time? That is biofeedback. Today, you will test whether watching your own body signals helps you stay calm under icy stress.
Driving question: Can you train your mind to calm your racing heart when your body feels sudden cold?
What you will learn
Today you will find out
- I can record steady resting heart and breathing rates with physiology sensors.
- I can observe how sudden cold makes heart and breathing rates rise.
- I can explain how watching live biofeedback helps a person stay calmer under stress.
- I can explain why the body speeds up its heart and breathing during stress.
- I can name real situations where athletes and patients use biofeedback training.
Why it matters: Biofeedback helps pilots, Olympic athletes, and people with migraines or anxiety take control of their physical stress reactions.
Safety first
Scientist Rules for Today
- Wear clean lab clothes or an apron. Keep water far from electronic cables.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Educational use only: use these sensors for classroom study, not for medical diagnosis.
- Ice water is very cold! If the subject feels painful numbness, remove the foot immediately.
- Place basins on thick towels to prevent slips and wet floors.
- Gently peel electrode tabs off skin when finished. Throw tabs into regular trash.
- Wash hands and feet after the experiment. Dry them fully.
What you need
- Go Direct EKG Sensor1
- Go Direct Respiration Belt1
- Electrode tabs (consumable)3 per subject
- large plastic wash basin1
- ice cubes3 cups
- paper towel1 roll
- exercise step stool1
- Tablet running Graphical Analysis1

Step 1 of 9
Connect sensors in Graphical Analysis
- Turn on both the Go Direct EKG Sensor and Go Direct Respiration Belt.
- Open Graphical Analysis on your tablet. Connect both sensors with Bluetooth.
- Turn off 'EKG' and 'Force'. Under sensor channels, select 'Heart Rate' and 'Respiration Rate'.
- Both sensors are charged with green power LEDs.
- Tablet Bluetooth is turned on.
- Hands are dry before you touch tablet and sensors.
Careful: If you select raw EKG or Force channels, the screen shows complicated waves instead of calculated rates. Select only 'Heart Rate' and 'Respiration Rate' channels in the sensor menu.

Step 2 of 9
Set up two graphs on screen
- Tap View (the small box icon). Select '2 Graphs'.
- Set the top graph to Heart Rate vs. Time and the bottom graph to Respiration Rate vs. Time.
- Tap Mode: set Rate to 1 sample/s and End Collection to 200 s.
- Tablet rests securely on the table.
- Two distinct graph panels are visible.
Careful: A collection time that is too short cuts off the experiment early. Make sure that you set collection time to 200 seconds.

Step 3 of 9
Fit the respiration belt around the subject
- Choose one student in your group to be the test subject.
- Wrap the respiration belt around the subject's ribcage just below the chest.
- Pull the strap until the small tension light on the belt glows steady GREEN.
- Subject is seated comfortably in the chair.
- Belt is over a single layer of clothes (T-shirt).
- Belt is not uncomfortably tight.
- The subject breathes comfortably while seated upright.
Careful: If the belt is too loose or too tight, the tension indicator will not glow green and readings fail. Tighten or loosen until the indicator light is solid green as you breathe normally.

Step 4 of 9
Attach the 3 EKG electrode tabs
- Wipe the subject's arm skin with a damp paper towel and dry it.
- Stick tab 1 on the inside of the RIGHT wrist. Press it flat.
- Stick tab 2 on the inside RIGHT and tab 3 on the inside LEFT upper forearm below the elbow, pressing flat.
- Skin is clean and completely free of lotion.
- Electrode tabs are fresh and sticky.
Careful: Oily or hairy skin causes loose tabs and loss of heart-rate signals. Wash and dry skin with soap and water if tabs fail to stick.

Step 5 of 9
Clip the EKG leads onto the tabs
- Attach the BLACK clip to the tab on the inside of the RIGHT WRIST (ground).
- Attach the GREEN clip to the tab on the RIGHT UPPER FOREARM (negative).
- Attach the RED clip to the tab on the LEFT UPPER FOREARM (positive).
- Clips match the diagram: Black = Right Wrist, Green = Right Forearm, Red = Left Forearm.
- Lead wires are loose and do not pull on the tabs.
- Subject rests both arms comfortably on their lap or chair armrests.
Careful: Incorrect lead colours or arm movement will cause noisy, incorrect heart readings. Double check colors: Black to right wrist, Green to right forearm, Red to left forearm.
4 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 7, Science, chapter 9: Life Processes in Animals
- Related Class 10, Science, chapter 6: Control and Coordination
- Direct Class 8, Biology, chapter 4: Endocrine System
Versions and what each needs
- Can you calm your heart?
Human Physiology Vol 2, 60 min, Based on a Vernier lab
Needs: Go Direct EKG Sensor, Go Direct Respiration Belt
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.