Experiments › Chemistry

Can you count atoms with electricity?

Avogadro

Grades 7-8Chemistry1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

A shiny copper coin next to an artist rendering of a stream of glowing electrons and copper atoms

Wonder

How can you count something that is too tiny for any microscope to see?

Show the answer

Every single atom is unimaginably tiny. But electricity flows as a stream of countable electrons. By timing the electric flow and weighing a metal strip before and after, you can count the atoms!

Shiny copper coins and a coil of bright copper wire resting on a wooden table in warm sunlight

Introduction

Counting the Invisible

If you hold a piece of copper in your hand, you are holding trillions upon trillions of copper atoms. No microscope can count them one by one. But what if we used electricity? When electric current flows through an acid bath, electrons pull copper atoms off a metal strip like tickets torn off a roll. Today, we will measure the electric current and find how many atoms are packed inside!

Driving question: Can we use an electric current to count atoms that are too small to see?

What you will learn

Today you will find out

  • I can explain how electricity moves copper atoms off a metal strip.
  • I can measure how much lighter the copper strip becomes after electrolysis.
  • I can record electric current and find its average value on a graph.
  • I can use current and mass loss to estimate how many atoms are in a mole.
  • I can follow safety rules around acids and electrical devices.

Why it matters: Counting atoms is how chemists mix the exact right amounts of medicines, battery materials, and solar panels without wasting a single speck.

Safety first

Laboratory Safety Rules

  • Wear splash goggles, chemical gloves, and an apron at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • 1 M sulfuric acid causes severe burns. Only the teacher pours and handles open acid containers.
  • Look for the ADULT NEEDED badge. Those steps use acid or wall power.
  • Never let the copper and zinc strips touch each other while power is on.
  • Keep all liquids at least 30 cm away from the computer and tablet.
  • Wash your hands fully with soap and water after the experiment.

What you need

  • Go Direct Constant Current System1 · teacher
  • Tablet running Graphical Analysis1
  • copper strip1 (approx. 2 x 10 cm)
  • zinc strip1 (approx. 2 x 10 cm)
  • 1 M sulfuric acid, H2SO4, solution150 mL · teacher
  • 250 mL beaker2
  • Digital balance (0.01 g precision)1 per class or group
  • steel wool pad1 small piece
  • Distilled water wash bottle1
  • Splash goggles and nitrile gloves1 set per person
Student rubbing a copper strip with steel wool

Step 1 of 8

Clean the metal strips

  1. Rub both sides of the copper strip with steel wool until shiny.
  2. Clean the zinc strip with steel wool if it looks dull.
  3. Wipe away any grey metal dust with a dry paper towel.
Stop and check
  • Safety goggles and gloves are on.
  • Table surface is dry and clear of paper.
  • Metal strips have no sharp burrs on edges.
  • Do not touch the shiny cleaned metal with bare fingers.

Careful: Metal slivers from steel wool can poke fingers. Dirt on metal stops electricity from an even flow. Wear gloves when you polish. Polish gently over a paper towel.

Copper strip resting on the pan of an analytical balance showing digital digits

Step 2 of 8

Weigh the copper strip

  1. Carefully place the dry, clean copper strip on the balance pan.
  2. Record the start mass in your data notebook to three decimal places (for example, 5.100 g).
  3. Remove the strip. Set it on a clean paper towel.
Stop and check
  • Balance is level and the pan is clean.
  • The copper strip is completely dry.
  • Zero the digital balance so the screen reads 0.000 g.

Careful: Fingerprints or wet drops add weight and give a false mass reading. Handle the strip only with gloved hands by its very top edge.

Teacher pouring clear acid from reagent bottle into glass beaker

Step 3 of 8 Teacher does this

Teacher pours the acid solution

  1. The teacher pours 1 M sulfuric acid into a 250 mL beaker until three-quarters full.
  2. Students keep hands off the beaker and observe from a safe distance.
  3. Place the beaker securely in the centre of the work area.
Stop and check
  • Adult wears chemical splash goggles, apron, and purple gloves.
  • Acid waste beaker and sodium bicarbonate neutraliser are nearby.
  • Students stand one step back from the area for acid.

Careful: 1 M sulfuric acid is corrosive and causes severe chemical burns to skin and eyes. Only the adult pours the acid. Wipe any drips immediately with moist paper towels.

Red clip attached to copper strip and black clip attached to zinc strip

Step 4 of 8 Teacher does this

Attach electrode clips to the strips

  1. Attach the red alligator clip firmly to the top of the copper strip.
  2. Attach the black alligator clip firmly to the top of the zinc strip.
  3. Do not put the metal strips into the acid beaker yet!
Stop and check
  • Current dial is turned completely to the minimum position.
  • The power unit is NOT plugged into wall mains yet.
  • Dry metal strips rest on the bench.
  • Check that the dial on the Constant Current System is turned fully counterclockwise to zero.

Careful: If clips touch or current flows too soon, sparks or short circuits can happen. Keep the metal strips well separated on a dry cloth. Double-check dial is at zero.

Two metal electrodes hanging in acid beaker without touching each other

Step 5 of 8 Teacher does this

Connect power and lower the electrodes

  1. The teacher plugs the Constant Current System power adapter into an electrical wall socket.
  2. Carefully lower both metal strips into the acid beaker to equal depths.
  3. Make sure the copper and zinc strips hang on opposite sides of the beaker.
Stop and check
  • The strips are positioned at least 3 cm apart in the beaker.
  • The dial is still in the minimum counterclockwise position.
  • Mains power cord is clear of walkways and water.
  • The two metal strips must never touch each other inside the liquid!

Careful: If electrodes touch, a short circuit occurs. This can damage equipment and cause acid splashes. Bend clips over the glass rim so electrodes hang securely. Make sure they do not move toward each other.

3 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Direct Class 12, Chemistry, chapter 2: Electrochemistry
Cambridge AS & A Level
  • Direct Level AS & A Level, Chemistry, chapter 20: Electrochemistry
IB Diploma
  • Direct Level DP, Chemistry, chapter Structure 1.4: Counting particles by mass: The mole

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.