Experiments › Physical Science
Can you design the best cold pack?
Good Cold Pack
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
How can a dry plastic bag turn freezing cold without being in a freezer?
Show the answer
When you pop an inner water pouch, dry crystals dissolve and swallow heat from the water. Scientists call this an endothermic process, and today you will measure it with a digital probe.

Introduction
The Science of Instant Freezing
When an athlete twists an ankle on the field, a coach grabs a plastic pouch, gives it a sharp squeeze, and it instantly turns ice-cold. There is no ice inside, and no battery power. Inside the pack, a small bag of water breaks open and mixes with dry salt crystals. As the crystals dissolve, they absorb thermal energy from the water. In this experiment, you will test five different substances to discover which one makes the most powerful cold pack.
Driving question: How can dissolving a dry powder make water freezing cold without an ice cube?
What you will learn
Today you will find out
- I can record temperature changes while dissolving different solids.
- I can tell if a dissolving process absorbs or releases heat energy.
- I can identify which chemical creates the coldest instant pack.
- I can safely weigh chemicals and collect sensor data.
- I can explain how first-aid cold packs work in real life.
Why it matters: Sports doctors rely on instant cold packs to reduce swelling immediately. Chemical engineers design these packs to be safe, cheap, and cold.
Safety first
Safe Science in the Lab
- Wear chemical splash goggles and lab gloves throughout this experiment.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Treat all laboratory powders as non-food grade. Never taste, eat, or smell any chemical.
- Citric acid and ammonium chloride can irritate skin and eyes. Rinse immediately if spilled.
- Stir gently with the temperature probe. Do not tap the probe tip forcefully against the glass beaker bottom.
- Wash your hands fully with soap and water after you finish the lab.
What you need
- Go Direct Temperature Probe1
- Tablet or Chromebook running Graphical Analysis1
- Digital balance (0.01 g precision)1 per station
- 50 mL beaker1
- 250 mL beaker1
- 10 mL graduated cylinder1
- Weighing paper squares5 sheets
- Test solids (NH4Cl, H3C6H5O7, KCl, NaHCO3, Na2CO3)3.0 g each
- Splash goggles and nitrile gloves1 pair per student

Step 1 of 7
Weigh five solid samples
- Measure exactly 3.0 g of ammonium chloride (NH4Cl) onto paper.
- Label the corner of the paper with its chemical formula.
- Repeat for citric acid, potassium chloride, sodium bicarbonate, and sodium carbonate with fresh paper.
- Goggles and gloves are on.
- The balance reads 0.00 g after you tare the paper.
- Sppatulas are wiped clean between powders.
- Place a piece of paper on the digital balance. Press Tare (zero).
Careful: Do not spill powder on your hands. Do not inhale dust. Do not mix powders on the balance. Scoop powders slowly. Do not blow on the balance pan. Keep each paper labelled.

Step 2 of 7
Measure room-temperature water
- Use your 10 mL graduated cylinder to measure exactly 10.0 mL of room-temperature tap water.
- Check the water level at eye level. The bottom of the curved meniscus must sit right on the 10 mL line.
- Pour the 10.0 mL of water into your clean 50 mL beaker.
- The 50 mL beaker is clean and completely dry inside before you add water.
- Water is at room temperature, not straight from a hot or cold tap.
Careful: Too much or too little water changes the concentration and temperature drop. Read the cylinder at eye level to get exactly 10.0 mL.

Step 3 of 7
Place probe in water and check stability
- Place the tip of the Go Direct Temperature Probe into the 10 mL of water in the 50 mL beaker.
- Stir gently with the probe for a few seconds.
- Watch the live temperature readout on your screen until the number becomes stable.
- Probe is submerged at least 2 cm in water.
- The beaker is stable and rests flat on the table.
Careful: You knock over the 50 mL beaker while you stir. Hold the beaker rim lightly with one gloved hand. Hold the probe in the other hand.

Step 4 of 7
Test ammonium chloride (NH4Cl)
- Tap Collect. Watch the initial baseline. At 15 seconds, carefully pour in the 3.0 g of ammonium chloride from your paper.
- Stir gently and continuously with the probe shaft until all crystals dissolve.
- When the temperature levels off and no longer drops, tap Stop.
- Collection has started and 15 seconds have elapsed.
- You pour the powder in all at once with no spills outside the rim.
- Tap Collect in Graphical Analysis and watch the graph for 15 seconds to establish a straight initial baseline.
Careful: If you stir vigorously, you can splash cold chemical solution or crack the glass beaker. Stir in smooth, quiet circles. Do not hit the sensor against the glass walls.

Step 5 of 7
Record minimum and maximum values
- Drag the vertical marker line to find the initial baseline temperature before the drop.
- Drag the line to the lowest valley to find the minimum temperature.
- Record the initial temperature and minimum temperature in your table. Calculate the difference.
- Data collection is stopped.
- The examine line is active on the graph.
- Tap any data point on your graph to open the Examine tool.
Careful: You select the wrong point before you reach the minimum. Scroll across the bottom of the curve to confirm the lowest value.
2 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 7, Chemistry, chapter 2: Physical and Chemical Changes
- Direct Class 8, Chemistry, chapter 11: Dissolution of Salts in Water
Versions and what each needs
- Can you design the best cold pack?
Middle School Science, 50 min, Based on a Vernier lab
Needs: Go Direct Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.