Experiments › Biology
Can you make bacteria glow?
Transform e coli
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 9 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
How can a deep-sea jellyfish teach land bacteria how to shine?
Show the answer
Jellyfish carry a DNA recipe for glowing green. Today, you will deliver that recipe into harmless bacteria and switch it on with sugar!

Introduction
Can You Make Bacteria Glow?
In the ocean, some jellyfish glow bright green in the dark. Their cells make a special protein called Green Fluorescent Protein. Can we borrow that glowing recipe and give it to harmless bacteria? Yes! Bacteria can absorb loose rings of DNA called plasmids. In this experiment, you will use a quick warm bath to help bacteria take up the glowing gene. Then, you will use a sugar switch to make them glow under ultraviolet light.
Driving question: Can we transfer a gene from a jellyfish into bacteria to make them glow?
What you will learn
Today you will find out
- I can explain how bacteria receive new DNA to change their traits.
- I can explain how antibiotic medicine helps us find transformed bacteria.
- I can carry out a 50-second heat shock at 42°C safely.
- I can observe which bacterial plates glow green under UV light.
- I can name real-life uses where friendly bacteria make medicine.
Why it matters: Scientists use this exact gene-delivery method to turn friendly bacteria into medicine factories that produce human insulin and vaccines.
Safety first
Microbiology Lab Rules
- Wear safety goggles, nitrile gloves, and a lab coat at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Although this E. coli strain is safe and non-pathogenic, treat all bacteria with respect.
- Never touch your mouth, eyes, or face during the lab. Never eat or drink anything.
- Place all used loops, pipets, and tubes immediately into the bleach disinfectant bath.
- Never look directly into the ultraviolet lamp. Always shine the lamp downward away from your eyes.
- Wash your hands fully with soap and warm water before you leave the lab room.
What you need
- Go Direct Temperature Probe1 per workstation
- E. coli starter plate with fresh colonies1 per workstation
- 4 agar plates (1 LB, 2 LB/amp, 1 LB/amp/ara)1 set of 4
- Rehydrated pGLO plasmid DNA vial1 vial on ice
- Transformation solution (CaCl2) and LB broth1 mL each
- Microcentrifuge tubes (+pGLO and -pGLO)2 tubes
- Foam microtube float and ice cup1 float and 1 foam cup
- Sterile transfer pipets and inoculation loops5 pipets and 7 loops
- 42°C water bath1 shared per room · teacher
- Handheld UV lamp or BlueView Transilluminator1 per room
- Disinfectant waste container (10% bleach)1 per table

Step 1 of 9
Label tubes and add transformation liquid
- Use a marker to label one microtube '+pGLO' and the second microtube '-pGLO'.
- Push both tubes into your foam rack and set the rack into crushed ice.
- Use a sterile transfer pipet to pipet 250 µL of cold transformation solution (CaCl2) into each tube.
- Gloves and goggles are on.
- Tubes are labelled clearly with marker pen.
- Tubes sit directly in crushed ice.
- Make sure that the bottom tips of both tubes touch the ice.
Careful: Warm solution reduces how well cells take up DNA later. Keep the tubes pushed deep into crushed ice so they stay near 0°C.

Step 2 of 9
Add bacterial colonies to both tubes
- Use a sterile blue loop to scrape off one healthy colony of bacteria from the agar surface.
- Twirl the loop inside the '+pGLO' tube until the colony dissolves.
- Repeat the process for the '-pGLO' tube with a fresh sterile loop.
- Do not set Petri dish lids down on the table.
- Use a fresh sterile loop for each tube.
- Disinfectant bleach container is within arm's reach.
- Open the E. coli starter plate just enough to reach in with a sterile blue loop.
- Drop each used loop into the bleach beaker immediately after you mix.
Careful: If the loop touches fingers or bench surfaces, it contaminates the culture. Keep loop tips in the air. Drop used loops directly into bleach.

Step 3 of 9
Add pGLO plasmid DNA and incubate on ice
- Dip a fresh sterile loop into the pGLO plasmid DNA tube.
- Mix the loopful of plasmid directly into the '+pGLO' tube.
- Close both caps. Push the tubes deep into crushed ice. Set a timer for 10 minutes.
- Plasmid goes ONLY into +pGLO.
- -pGLO stays free of plasmid DNA.
- Timer is set for 10 minutes.
- Check that a thin shiny film of plasmid liquid fills the small loop ring, like a soap bubble.
- Do NOT add any plasmid to the '-pGLO' tube.
Careful: If you add plasmid to -pGLO by accident, you ruin your control comparison. Double-check tube labels before you dip the loop into liquid.

Step 4 of 9
Label your 4 agar test plates
- Arrange your 4 agar plates upside down while tubes chill on ice.
- Label rims: plate 1: 'LB -pGLO', plate 2: 'LB/amp -pGLO', plate 3: 'LB/amp +pGLO', plate 4: 'LB/amp/ara +pGLO'.
- Add your group name and class period to each plate rim.
- Write on the plastic bottom that contains agar. Never write on the removable lid.
- Write near the outer edge so the center stays clear to see colonies.
- Use a marker to write on the bottom rim of each plate (not the lid).
Careful: Lids can swap or rotate. Then you cannot identify your results. Always write directly on the bottom agar dish.

Step 5 of 9 Teacher does this
Execute the 50-second heat shock
- After the 10-minute chill, carry the foam float that holds both tubes to the 42°C water bath.
- Immerse the tubes in the water bath for exactly 50 seconds.
- Immediately move the foam float back into crushed ice for 2 minutes.
- Water bath reads 42°C on the sensor.
- Stopwatch or phone timer is set to 50 seconds.
- Ice cup is ready right next to the water bath.
- Check that the temperature sensor confirms the bath is at 42°C.
- Push tubes down so water surrounds their tips.
- Move the foam float back into crushed ice the second the timer hits 50.
Careful: If you leave tubes in 42°C water for more than 50 seconds, you cook and kill the bacteria. If you move too slowly, pores will not open. Adult supervises water bath. Transfer rapidly back to ice at exactly 50 seconds.
4 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Level AS & A Level, Biology, chapter 19: Genetic technology
Versions and what each needs
- Can you make bacteria glow?
Advanced Biology, 85 min, Based on a Vernier lab
Needs: Go Direct Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.