Experiments › Chemistry

Can you measure fire without a flame?

Heat of Combustion Mg

Grades 7-8Chemistry1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

A festive sparkler burning with an intense white flare and showering sparks against a twilight sky

Wonder

Can you measure the blazing heat of fireworks without starting a fire?

Show the answer

Yes! Burning fireworks release enormous energy. Scientists call it heat of reaction, and today you will measure it safely without lighting a flame.

A dazzling white safety flare burning brightly outdoors against a dark twilight sky

Introduction

Can You Measure Fire Without a Flame?

When magnesium metal burns in air, it creates a blinding white flare used in flares and fireworks. That reaction is far too violent to trap in a classroom beaker. But nature has a clever rule: total energy change is always the same, no matter what path a reaction takes. In this experiment, you will mix two milder ingredients with acid in an insulated cup. By tracking gentle temperature rises, you will crack the puzzle and find the metal's fierce burning heat!

Driving question: How can we find the intense burning heat of magnesium without ever lighting a match?

What you will learn

Today you will discover

  • I can explain how exothermic reactions make solutions warmer.
  • I can record starting and peak temperatures on a digital graph.
  • I can compare temperature jumps to find which reaction released more heat.
  • I can work safely around acid cups and digital probes.
  • I can explain why scientists use safe stepping-stone reactions to study dangerous ones.

Why it matters: Rocket engineers and materials scientists cannot always ignite dangerous rocket fuels just to measure their energy. They use stepping-stone reactions to calculate energy safely.

Safety first

Safety Rules for Today

  • Wear chemical splash goggles, protective gloves, and a lab apron at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Hydrochloric acid can irritate skin and damage eyes. Only your teacher dispenses acid.
  • Magnesium reacts with acid and produces hydrogen gas. Keep all flames away. Do not breathe vapors directly.
  • Never ignite magnesium ribbon inside the classroom.
  • Keep all liquids at least 30 cm away from computers and tablets.
  • Wash hands fully with soap and water after you clean up.

What you need

  • Go Direct Temperature Probe1 per group
  • Stir Station1 per group
  • Electrode Support1 per group
  • Tablet running Graphical Analysis1 per group
  • 1.00 M Hydrochloric acid solution200 mL per group · teacher
  • white chemical powder1.00 g per group
  • metal ribbon strip0.50 g per group
  • 400 mL beaker1 beaker and 2 foam cups
  • 100 mL graduated cylinder1 per group · teacher
  • magnetic stir bar1 per group
  • Digital balance (0.01 g precision)1 per classroom or shared
  • Splash goggles and nitrile gloves1 set per student
Student hand adjusting the probe clamp on the Stir Station above the cup

Step 1 of 8

Assemble your calorimeter

  1. Place a clean polystyrene foam cup inside a 400 mL glass beaker for support.
  2. Set the beaker in the centre of the Stir Station platform.
  3. Clamp the Electrode Support onto the vertical rod of the Stir Station.
  4. Slide the Go Direct Temperature Probe into the support so it stays upright.
Stop and check
  • The beaker sits flat and sturdy on the stirrer platform.
  • The foam cup has no cracks or leaks.
  • The clamp is tightened securely on the metal rod.

Careful: The cup could tip over if not supported by the heavy glass beaker. Always keep the foam cup nestled inside the 400 mL beaker.

Teacher in purple gloves carefully pouring clear acid from a cylinder into the foam cup

Step 2 of 8 Teacher does this

Teacher adds acid to the cup

  1. Your teacher measures exactly 100.0 mL of 1.00 M hydrochloric acid in a graduated cylinder.
  2. The teacher carefully pours the acid into your foam cup.
  3. Add one clean magnetic stir bar gently into the cup.
  4. Lower the probe into the acid until the acid covers half of the metal tip.
Stop and check
  • Everyone has safety goggles and aprons on.
  • The beaker and cup are stable on the Stir Station.
  • Students keep hands away from the cup while they pour.

Careful: Acid splashes can cause skin burns and eye damage. Only the teacher pours the acid. Never lean over the cup.

Student hand using a spatula to add white powder to weighing paper on a digital balance

Step 3 of 8

Weigh the magnesium oxide powder

  1. Put a clean paper for balance on the digital balance. Press Zero (Tare).
  2. Carefully transfer about 1.00 g of white magnesium oxide (MgO) powder onto the paper.
  3. Record the exact mass shown on the balance in your lab notebook.
Stop and check
  • The balance displays 0.00 g before you add powder.
  • The spatula is clean and completely dry.

Careful: If you spill powder on the balance pan, it ruins the measurement. Add powder slowly in small scoops until you reach about 1.00 g.

Calorimeter cup with liquid swirling smoothly under gentle magnetic stirring

Step 4 of 8

Start stirring and record baseline

  1. Turn the Stir Station knob to a gentle, steady speed (around setting 3 or 4).
  2. Make sure that the stir bar does not hit the temperature probe stem.
  3. Tap Collect in Graphical Analysis.
  4. Watch the graph for 15 seconds until the temperature line is completely flat. Note this initial temperature (t1).
Stop and check
  • The stir bar creates a smooth gentle whirlpool without splashes.
  • The probe stays still in its clamp.

Careful: If the stir bar turns too fast, acid can splash out of the cup. Keep the speed dial low. Increase slowly until the liquid mixes gently.

Student gloved hand pouring white powder from weighing paper into the cup

Step 5 of 8

Reaction 1: Add magnesium oxide

  1. Carefully pour the 1.00 g of magnesium oxide powder into the stirred acid.
  2. Watch the graph on your tablet as the powder dissolves.
  3. The temperature will climb steadily over 2 to 4 minutes.
  4. When the temperature stops its increase and begins to drop, tap Stop. Record the highest temperature (t2).
Stop and check
  • The baseline temperature has been recorded.
  • The powder slides in smoothly and does not touch the probe.

Careful: If you pour too fast, powder dust can blow into your eyes. Wear goggles. Pour close to the top of the cup.

3 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 10, Science, chapter 1: Chemical Reactions and Equations
  • Related Class 10, Science, chapter 3: Metals and Non-metals
ICSE (CISCE)
  • Direct Class 9, Chemistry, chapter 6: Study of the First Element Hydrogen
Cambridge AS & A Level
  • Direct Level AS & A Level, Chemistry, chapter 6: Enthalpy changes

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.