Experiments › Chemistry

Can you swap a molecule's parts?

SN1 tBuCl Synthesis

Grades 7-8Chemistry1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Two clear liquid bottles with molecular swap illustration

Wonder

How do chemists trade one atom for another inside a molecule?

Show the answer

Just like snapping off one Lego brick and attaching another, chemists swap parts of molecules. Today you will see an alcohol turn into a chlorinated compound, then race it through a high-tech sensor to prove it changed.

A chain of colorful snap-together toy blocks on a wooden table with one modular piece swapped out

Introduction

The Great Atomic Swap

Can you change what a chemical is without destroying it? Yes! Chemists do this by running substitution reactions. Today, we mix an alcohol with acid so a water piece leaves and a chlorine atom takes its place. To prove the swap happened, we use two tests: a molecular race track called gas chromatography and an instant white cloud test. Let us see how atoms make over their identities!

Driving question: Can we swap a single piece of a molecule and prove it changed?

What you will learn

Today you will find out

  • I can explain how one chemical group swaps for another in a reaction.
  • I can identify separate liquid layers in a funnel.
  • I can match a peak on a graph to prove what chemical was made.
  • I can explain why strong acids need special fume hood handling.
  • I can connect chemical testing to real-world medicine and forensics.

Why it matters: Pharmaceutical scientists build lifesaving medicines by swapping atoms onto carbon backbones. Gas chromatographs verify those medicines are 100% pure.

Safety first

Scientist Safety Rules

  • Wear splash goggles, protective lab coat, and chemical-resistant gloves at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Concentrated 12 M hydrochloric acid is highly corrosive: ONLY the teacher dispenses and mixes it in the fume hood.
  • Never inhale vapors from organic solvents like tert-butanol or tert-butyl chloride.
  • Vent the separatory funnel. Point the tip away from people to release gas pressure safely.
  • The 1 microliter syringe needle is extremely sharp and fragile; handle with extreme caution.
  • Silver nitrate stains skin and clothes dark brown or black. If it touches you, rinse immediately with plenty of water.

What you need

  • Go Direct Mini GC1 · teacher
  • Tablet running Graphical Analysis1
  • separatory funnel1 (125 mL) · teacher
  • ring stand with support ring1
  • microliter syringe1 (1 uL) · teacher
  • 6.0 M Hydrochloric acid solution15 mL (12 M concentrated) · teacher
  • clear solution in a reagent bottle4.0 g tert-butanol · teacher
  • Test tubes and rack3 tubes (13 x 100 mm) in rack
  • clear liquid in a wash bottle5 mL 1% ethanolic AgNO3 · teacher
  • Splash goggles and nitrile gloves1 set per person
Adult pouring acid into a chilled flask inside a fume hood

Step 1 of 8 Teacher does this

Adult prepares cold acid in fume hood

  1. The adult measures 15 mL of concentrated hydrochloric acid in a graduated cylinder.
  2. Transfer the acid into a 50 mL flask inside the fume hood.
  3. Chill the flask in an ice water bath inside a 250 mL beaker.
  4. Cool the acid to prevent excessive heat and vapor when the chemicals mix.
Stop and check
  • The fume hood exhaust fan runs.
  • The adult wears splash goggles, a coat, and purple gloves.
  • Students observe from a safe distance outside the sash.

Careful: Concentrated acid fumes irritate eyes and lungs; splashes cause severe chemical burns. Work only inside the fume hood sash. Keep ice bath stable on the bench.

Pouring tert-butanol into the clamped separatory funnel

Step 2 of 8 Teacher does this

Assemble funnel and add reactants

  1. Clamp the separatory funnel into the support ring on the stand.
  2. Make sure that the bottom stopcock tap is closed horizontally.
  3. The adult pours the chilled acid through a glass funnel into the top.
  4. Weigh 4.0 g of tert-butanol and carefully add it to the funnel.
Stop and check
  • The stopcock valve at the bottom of the funnel is closed tightly.
  • A waste beaker is placed beneath the funnel stem just in case.

Careful: An open stopcock will spill concentrated acid onto the bench or floor. Always double check that the stopcock is crosswise (closed) before you add liquids.

Inverting separatory funnel and opening stopcock to vent pressure

Step 3 of 8 Teacher does this

Adult mixes, vents pressure, and shakes

  1. The adult swirls the uncapped funnel gently for 5 minutes.
  2. Insert the glass stopper. Invert the funnel. Immediately open the stopcock to vent gas.
  3. Point the drain stem toward the back of the fume hood away from everyone.
  4. Close the tap, shake gently, and vent frequently over 15 minutes.
Stop and check
  • Funnel tip points toward the rear wall of the fume hood.
  • Stopper is held firmly in the palm so it cannot pop open.

Careful: Gas pressure builds up fast when chemicals mix. If you do not vent, acid spray can blow off the stopper. Vent immediately after you invert the funnel. Vent every few seconds while you shake the funnel.

Draining lower layer from separatory funnel into an Erlenmeyer flask

Step 4 of 8 Teacher does this

Separate layers and wash the organic liquid

  1. Return the funnel to the ring stand and remove the top stopper.
  2. Watch the two clear layers separate: the dense watery acid settles at the bottom.
  3. Drain the lower acid layer into an Erlenmeyer flask labelled waste.
  4. Add 30 mL of sodium bicarbonate solution to neutralize leftover acid, swirl, and vent.
  5. Drain the watery layer, then repeat the wash with 30 mL of saturated salt water.
Stop and check
  • You remove the top stopper before you open the tap so liquid drains smoothly.
  • Waste flask is positioned under the stem.

Careful: When you add sodium bicarbonate, fizzy carbon dioxide gas bubbles can foam over. Add sodium bicarbonate slowly. Swirl gently until bubbles stop before you put the stopper in.

Student weighing a small glass vial containing clear liquid on an electronic balance

Step 5 of 8 Teacher does this

Dry and weigh the synthesized product

  1. Add a pea-sized scoop of anhydrous sodium sulfate powder to a 10 mL vial.
  2. Transfer the top organic product layer from the funnel into the vial.
  3. Swirl gently: the white powder clumps together as it sponges up tiny water droplets.
  4. Weigh a clean empty vial on the digital balance, record the mass, and pipet the clear liquid into it.
Stop and check
  • A loose cap covers the vial during the 5 minute step.
  • Pipet does not pick up any white sodium sulfate powder.

Careful: If you transfer dry powder into the final vial, syringe needles clog during GC tests. Draw only the clear liquid above the solid clumps with the pipet.

3 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

Cambridge AS & A Level
  • Related Level AS & A Level, Chemistry, chapter 16: Halogenoalkanes

Versions and what each needs

  • Can you swap a molecule's parts?
    Organic Chemistry, 75 min, Based on a Vernier lab
    Needs: Go Direct Mini GC

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.