Experiments › Chemistry
Cleaning crystals with hot water
Recrystallization
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 9 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
How can you clean dirty chemical crystals without ever touching them?
Show the answer
Dirty crystals dissolve into hot water. As the water cools slowly, only clean particles link together into pure crystals, leaving the dirt trapped behind in the liquid. Scientists call this recrystallization.

Introduction
Can dirty crystals wash themselves clean?
Imagine your sugar or salt was mixed with tiny specks of dirt. You cannot pick them out by hand. How do scientists make crystals pure? They dissolve them in hot water and cool them slowly! As the water cools, the particles lock together into sparkling clean crystals, leaving the dirt behind in the liquid. Scientists call this recrystallisation. Today you will clean dirty crystals and prove they are pure.
Driving question: How can you clean dirty crystals using only hot water?
What you will learn
Today you will find out
- I can explain why hot water dissolves more solid than cold water.
- I can observe and describe pure crystals forming as a liquid cools.
- I can separate solid crystals from liquid using a filter funnel.
- I can use a melting point graph to tell if crystals are pure.
- I can name real-world industries that purify substances using crystallization.
Why it matters: Pharmaceutical factories use recrystallization to ensure life-saving medicines contain zero harmful impurities before turning into pills.
Safety first
Scientist Rules for Today
- Wear safety goggles, lab apron, and nitrile gloves at all times. Chemicals irritate eyes and skin.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Hot plates reach over 150 °C. Only the teacher adjusts hot plates and moves hot glassware.
- Look for the ADULT NEEDED badge. Those steps require adult hands or direct supervision.
- Never inhale vapors directly or taste any chemical or tablet in the laboratory.
- The Go Direct Melt Station gets extremely hot. Never touch the heating block with bare fingers.
- Wash your hands fully with soap and water before you leave the lab.
What you need
- Go Direct Melt Station1 per station · teacher
- Go Direct Wide Range Temperature1 per station
- laboratory hot plate1 per group · teacher
- vacuum filtration apparatus1 setup per group
- 100 mL beakers1
- 250 mL beaker1
- contaminated benzoic acid1.0 g
- glass capillary melting tubes3 tubes
- Digital balance (0.01 g precision)1 per station
- Distilled water wash bottle1 bottle (chilled on ice)
- circular filter paper3 sheets
- watch glass1

Step 1 of 9
Weigh the dirty benzoic acid sample
- Place an empty weigh boat on the balance. Press zero.
- Use a clean spatula to add about 1.0 g of the blue-tinted benzoic acid powder.
- Record the exact mass to three decimal places in your data notebook.
- Goggles and blue student gloves are on.
- Balance pan is clean and dry.
Careful: Benzoic acid powder can irritate eyes if touched, and chemical dust should not be inhaled. Transfer powder gently with a spatula. Never blow loose powder away.

Step 2 of 9 Teacher does this
Add water and heat until dissolved
- Transfer the weighed solid and 15 mL of distilled water into a clean 100 mL beaker.
- The adult places the beaker onto the hot plate on low heat.
- Stir gently with a glass rod until all white solid completely disappears.
- Hot plate cord is safely tucked away from walkways.
- Adult wears purple gloves and heat protection.
- Students keep hands 20 cm back from the hot surface.
Careful: The hot plate surface and beaker get hot enough to cause skin burns. Liquid can splatter if boiled hard. Heat gently on low. Adult handles the beaker with insulated grips.

Step 3 of 9 Teacher does this
Cool slowly on the bench to grow crystals
- The adult carefully moves the hot beaker off the hot plate onto the bench.
- Watch through the side as temperature drops and needle-like crystals sprout.
- Leave it undisturbed on the table for 10 minutes until room temperature.
- Clear bench area set aside away from table edges.
- Beaker is placed on a heat-resistant ceramic mat.
- No one bumps the table while crystals form.
- Do not stir or shake the beaker while it cools.
Careful: Hot glass looks identical to cold glass. If you move or shake the beaker, you disrupt pure crystal growth. Do not touch the beaker while it cools. Let it sit completely still.

Step 4 of 9
Chill in an ice water bath
- Fill a 250 mL beaker half full with ice cubes and cold water.
- Gently lower your crystal beaker into the ice bath.
- Chill for 5 minutes so nearly all dissolved benzoic acid crystallizes out.
- The crystal beaker has already cooled to room temperature.
- Ice bath water is not high enough to overflow into the inner beaker.
Careful: Ice water can spill inside your crystal beaker and dilute your product. Keep water level in the ice bath below the rim of the 100 mL beaker.

Step 5 of 9 Teacher does this
Weigh filter paper and set up suction
- Weigh one dry circle of filter paper and record its mass to three decimal places in your table.
- Place the filter paper flat inside the Buchner funnel.
- The adult switches on the vacuum suction trap.
- Filter flask is clamped tightly to the ring stand.
- Safety trap flask is connected between the funnel and suction line.
Careful: A top-heavy filter flask can tip over and smash if not clamped securely. Make sure the ring stand clamp holds the neck of the filter flask firmly.
4 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 11, Chemistry, chapter 2: Organic Chemistry: Some Basic Principles and Techniques
Versions and what each needs
- Cleaning crystals with hot water
Organic Chemistry, 90 min, Based on a Vernier lab
Needs: Go Direct Melt Station, Go Direct Wide-Range Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.