Cracking the crystal code
Analysis Alum
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can two plain white powders look identical but have completely different secret melting points?
Show the answer
Every pure crystal melts at an exact fingerprint temperature. Some crystals even lock hidden water inside their dry solid walls. Today you crack the code of alum crystals.

Introduction
Cracking the Crystal Code
Many white powders look exactly the same on a lab bench: sugar, salt, and alum. How can a chemical detective prove which one is which? Pure crystals have a unique melting temperature, like a secret fingerprint. Also, alum crystals contain invisible water molecules locked tightly inside their solid shapes. Today, you will use a Go Direct Melt Station to watch your crystals melt through a magnified window, and measure their trapped water.
Driving question: How can we prove the chemical identity of mystery white crystals using heat and mass?
What you will learn
Today you will find out
- I can find the exact temperature where a crystal starts and finishes melting.
- I can explain what water of hydration means in a solid crystal.
- I can find the mass of trapped water driven off by heat.
- I can pack a capillary tube and follow lab safety around hot equipment.
- I can name real jobs that use melting point and mass tests to check purity.
Why it matters: Pharmaceutical factories must check every medicine batch to ensure it is pure before giving it to patients. Melting tests catch dangerous fake drugs.
Safety first
Scientist Rules for Today
- Wear splash goggles, a protective lab apron, and heat-resistant gloves when you heat materials.
- Purple gloves = teacher does it. Blue gloves = you do it.
- The Melt Station heating block gets hotter than 100°C. Never touch the metal heating slots.
- Look for the ADULT NEEDED badge. Only an adult handles the open gas burner and hot crucibles that glow.
- Never touch a heated crucible with bare fingers: use metal crucible tongs.
- Capillary tubes are extremely thin glass. If one breaks, do not touch the shards with bare fingers.
- Wash your hands fully with soap at the end of class.
What you need
- Go Direct Melt Station
- glass capillary melting tubes
- mortar and pestle
- white chemical powder
- porcelain crucible and lid
- Digital balance (0.01 g precision)
- laboratory gas burner
- ring stand with support ring
- metal tweezers
- Tablet running Graphical Analysis

Step 1 of 8
Grind alum crystals to fine powder
- Place about half a gram of dry alum crystals into the mortar.
- Gently grind the crystals with the pestle into a smooth, fine white powder.
- Gather the powder into a small pile in the centre of the mortar.
- Wear safety goggles and blue gloves.
- The mortar is clean and dry.
- Do not taste or inhale the powder.
Careful: If you crush crystals too hard, dust can fly into the air or into your eyes. Grind with a gentle circular motion; keep goggles on at all times.

Step 2 of 8
Pack the capillary tube
- Push the open end of a glass capillary tube straight down into the powder pile.
- Turn the tube over so the sealed end is down.
- Tap gently on the benchtop until the white solid is about 1 cm deep at the bottom.
- Check that one end of the capillary tube is melted shut.
- Tap gently: glass capillary tubes can snap under pressure.
Careful: Thin glass tubes snap easily if pressed too hard against the bench. Tap very lightly or drop the tube down an upright plastic straw.

Step 3 of 8
Insert tube and start rapid heating
- Carefully lower the tube into one of the three slots on top of the Melt Station.
- Tap Collect in Graphical Analysis.
- Turn the dial on the Melt Station to Rapid Heat to warm up quickly.
- The outside of the capillary tube is wiped clean.
- The sensor connects and shows live temperature on the tablet.
- The blue light for the fan turned off when you switched to heat.
- Wipe any loose powder from the outside of the capillary tube with a tissue.
Careful: The heating block inside gets extremely hot and can cause burns. Never touch the metal slots with bare skin. Hold only the top of the glass tube.

Step 4 of 8
Slow the heating and observe melting
- When the temperature reaches 80°C on your tablet, turn the dial down to near 90°C.
- Record the temperature when the first liquid drops appear.
- Record the temperature when all white powder turns completely into clear liquid.
- Slow down the heat before 80°C so you do not overshoot the melt point.
- One student watches the lens, one student watches the tablet screen.
- Look closely through the observation window.
Careful: If you heat too fast, you miss the exact start of the melt. Turn the knob back to a slow heat rate when you are near 80°C.

Step 5 of 8
Cool down the Melt Station
- Tap Stop in the Graphical Analysis app.
- Turn the Melt Station control dial to Fan/Cool.
- Leave the hot capillary tube in place until the block cools down.
- Data collection stopped.
- Dial turned to the blue fan icon.
- Do not attempt to pull out the hot capillary tube yet.
- Listen for the internal fan and look for the blue LED light.
Careful: If you touch the glass tube while the heater is at 95°C, you can burn your fingers. Wait until the unit cools before you discard the tube.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Level AS & A Level, Chemistry, chapter 3: Atoms, molecules and stoichiometry
- Related Level DP, Chemistry, chapter Structure 1.4: Counting particles by mass: The mole
Versions and what each needs
- Cracking the crystal code
Advanced Chemistry, 75 min, Based on a Vernier lab
Needs: Go Direct Melt Station
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.