Does saltier water carry more electricity?

Conductivity Solutions

Grades 7-8Chemistry1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

An electric hair dryer resting on a bathroom countertop next to pooled water droplets

Wonder

Why is an electric appliance dangerous around wet, salty hands?

Show the answer

Pure water barely carries any electric current. But dissolve a pinch of salt, and charged particles called ions rush to carry electricity. Today, you will count drops and watch conductivity climb!

A drinking glass of water on a wooden kitchen table with dissolving table salt and a ceramic shaker beside it

Introduction

The Secret Movers in Salty Water

Pure distilled water has almost no free electrical charges, so electricity cannot flow easily through it. When you drop table salt into water, the salt crystals do something amazing: they break apart into tiny charged particles called ions. These dissolved ions swim freely through the water and carry electrical charges from one point to another. In this experiment, you will add drops of salt solution one by one to see how concentration and chemical formula change electrical conductivity.

Driving question: Why does salty water conduct electricity when pure water cannot?

What you will learn

Your Science Mission

  • I can measure how conductivity changes as I add drops of salt solution.
  • I can explain why dissolving salt makes water conduct electricity.
  • I can compare different salts to see which one releases more ions into water.
  • I can position the probe and use a magnetic stirrer safely without hitting the sensor.
  • I can describe how conductivity testing checks drinking water and body fluids.

Why it matters: Environmental scientists test river pollution with conductivity sensors, and doctors monitor electrolytes to keep patients hydrated.

Safety first

Lab Rules for Today

  • Wear chemical splash goggles and protective gloves at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Salt solutions can irritate eyes and skin. Rinse immediately with water if splashed.
  • Keep liquids at least 30 cm away from your tablet or laptop.
  • Clamp the Conductivity Probe securely so the magnetic stir bar never hits the sensor body.
  • Never taste any chemical solution in the laboratory.
  • Wash your hands with soap and water after you complete the experiment.

What you need

  • Go Direct Conductivity Probe1
  • Vernier Stir Station and stir bar1 station, 1 bar
  • Electrode Support1
  • 100 mL beakers3
  • 1.0 M NaCl in dropper bottle1 dropper bottle (about 15 mL)
  • 1.0 M CaCl2 in dropper bottle1 dropper bottle (about 15 mL)
  • 1.0 M AlCl3 in dropper bottle1 dropper bottle (about 15 mL)
  • Distilled water wash bottle1 filled bottle (500 mL)
  • Splash goggles and nitrile gloves1 set per person
Student placing a magnetic stir bar gently into a 100 mL beaker with 70 mL of water

Step 1 of 6

Pour pure water and prepare your beaker

  1. Add 70 mL of distilled water to a clean 100 mL glass beaker.
  2. Place the magnetic stir bar gently into the bottom of the beaker.
  3. Set the beaker squarely on top of the Vernier Stir Station plate.
Stop and check
  • Goggles and gloves are on.
  • The beaker is clean and free of cracks.
  • You use distilled water, not tap water.
  • Put on your safety goggles and light blue lab gloves.

Careful: If you drop the magnetic stir bar heavily into the beaker, you can crack the glass base. Tilt the beaker slightly and slide the stir bar down the side gently.

Conductivity Probe held in support arm submerged in beaker above spinning stir bar

Step 2 of 6

Mount and position the Conductivity Probe

  1. Clamp the Go Direct Conductivity Probe securely in the support bracket.
  2. Lower the probe until water fully covers the oval slot near the tip.
  3. Turn the Stir Station dial to create a gentle, steady swirl that does not splash.
Stop and check
  • The support clamp is tightened firmly so the probe cannot slip.
  • The stir bar spins freely and does not hit the probe.
  • Slide the Electrode Support arm onto the vertical rod of the Stir Station.
  • Make sure the probe tip hangs at least 1 cm above the magnetic stir bar.

Careful: If the probe touches the stir bar while it spins, the graphite electrodes can chip or break. Spin the stir bar slowly by hand first to confirm 1 cm of clearance below the probe.

Student tapping Keep Point on tablet screen showing baseline reading for zero drops

Step 3 of 6

Record zero drops for pure water

  1. Tap Collect in Graphical Analysis to start the run.
  2. Before you add any drops, tap Keep.
  3. Type 0 as the volume in drops. Then tap Keep Point.
Stop and check
  • The stirrer spins gently.
  • The live reading is stable and near zero.
  • No salt drops have been added yet.
  • Check the live reading: distilled water should read under 30 µS/cm.

Careful: If the baseline reads above 50 µS/cm, tap water or dirty glassware contaminates your test. Rinse the beaker and probe with fresh distilled water and test again.

Student dispensing drops vertically into beaker while data points plot on tablet

Step 4 of 6

Test 1.0 M Sodium Chloride (NaCl)

  1. Gently squeeze out exactly 1 drop of NaCl solution into the water.
  2. Wait 5 seconds for the reading to stabilize. Tap Keep. Type 1. Then tap Keep Point.
  3. Repeat until you reach 8 drops in total. Tap Stop when you record all 8 drops.
Stop and check
  • The dropper bottle is held straight down (vertical) for uniform drops.
  • The solution mixes continuously as drops fall in.
  • Hold the 1.0 M NaCl dropper bottle completely vertical over the stirred beaker.

Careful: If you tilt the dropper, drops become too small or too large. This creates an uneven line. Keep the bottle completely vertical directly above the water surface.

Student rinsing the Conductivity Probe tip with distilled water from a wash bottle

Step 5 of 6

Rinse and test 1.0 M Calcium Chloride (CaCl2)

  1. Rinse the probe and stir bar with distilled water. Blot them dry with a tissue. Add 70 mL of fresh distilled water.
  2. Return the clean stir bar to the beaker, tap Collect, choose New Run, and record 0 drops first.
  3. Add 1.0 M CaCl2 one drop at a time up to 8 drops. Then tap Stop.
Stop and check
  • You fully rinsed the probe with distilled water.
  • The new 70 mL water reads near zero before you add CaCl2 drops.
  • Empty the salty water into a waste beaker. Retrieve the stir bar with a rod. Fully rinse the probe tip and beaker with distilled water from the wash bottle.

Careful: Leftover salt from the previous trial makes the new baseline artificially high. Rinse the probe tip with distilled water until the live reading drops below 30 µS/cm.

1 more step, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 11, Chemistry, chapter 1: Some Basic Concepts of Chemistry
  • Related Class 12, Chemistry, chapter 2: Electrochemistry
Cambridge AS & A Level
  • Direct Level AS & A Level, Chemistry, chapter 1: Atomic structure
  • Related Level AS & A Level, Chemistry, chapter P2: Practical skills 2

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.