Experiments › Biology

Does standing help you breathe more?

Spirometry and Position

Grades 7-8Biology1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

A person standing tall while taking a deep breath outdoors against the morning sky

Wonder

Why do singers and public speakers almost always stand up when performing?

Show the answer

Standing frees your chest muscles and lets your diaphragm move down without squeezing your belly. Today you will measure your own lung power sitting versus standing.

Side comparison showing an upright posture versus a slouched seated posture

Introduction

Does Standing Help You Breathe More?

When you sit slouched at a desk, your stomach organs press up against your diaphragm. When you stand up straight, gravity helps pull those organs down, giving your lungs extra room to expand. In this lab, you will use a Go Direct Spirometer to measure how much air your lungs move during quiet breathing and during your biggest possible breath.

Driving question: Does standing up give your lungs more space to fill with air than sitting down?

What you will learn

Today you will discover

  • I can measure normal and maximum breath volumes using a spirometer.
  • I can find lung volumes by looking at the peaks on my breathing graph.
  • I can compare my lung capacity between sitting and standing postures.
  • I can explain why upright postures allow deeper breaths.
  • I can explain why hospital patients use breathing exercisers.

Why it matters: Hospital patients who stay in bed can struggle to ventilate their lungs. Understanding posture helps doctors prevent lung infections.

Safety first

Hygiene and Testing Rules

  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Never share mouthpieces or bacterial filters. Every student must use their own fresh filter and mouthpiece.
  • Do not volunteer if you have a cold, cough, asthma attack, or respiratory illness.
  • Wear clean gloves when you assemble the filter and mouthpiece.
  • Stop immediately if you feel dizzy or lightheaded when you take deep breaths.
  • Hold the sensor firmly with both hands and brace your arms on a steady table.
  • Put used cardboard mouthpieces and filters in the correct trash bin.

What you need

  • Go Direct Spirometer1 per group
  • Disposable bacterial filters1 per volunteer
  • Disposable mouthpieces1 per volunteer
  • Nose clip1 per group
  • Tablet running Graphical Analysis1 per group
  • Alcohol prep wipes1 pack per class
Assembling the mouthpiece and filter onto the spirometer

Step 1 of 6

Assemble the filter and mouthpiece

  1. Pick up a new bacterial filter and a new disposable mouthpiece.
  2. Push the wider end of the bacterial filter firmly into the Inlet side of the spirometer.
  3. Push the mouthpiece onto the other end of the bacterial filter.
Stop and check
  • The filter and mouthpiece are brand new out of the package.
  • Your hands are clean and gloved in light blue nitrile gloves.
  • Make sure the connections are snug so no air escapes through the joints.

Careful: If you use a shared mouthpiece, you can spread illness. Only handle your own mouthpiece. Do not let it touch the lab table.

Forearms braced on table holding spirometer upright while zeroing

Step 2 of 6

Hold steady and zero the sensor

  1. Have the volunteer sit comfortably in a chair with back straight.
  2. Hold the spirometer vertically with both hands and brace both forearms on the sturdy table.
  3. A teammate taps the Flow Rate meter in the app and selects Zero.
Stop and check
  • The sensor is held perfectly upright.
  • Forearms are firmly braced against the table surface.
  • Nobody blows or breathes near the mouthpiece.
  • Keep the sensor completely still and do not breathe through it yet.

Careful: If you zero the sensor when it moves or when air blows, the baseline drifts by a large amount. Do not move your hands. Hold your breath away from the tube when you zero the sensor.

Nose clip in place closing nostrils

Step 3 of 6

Put on the nose clip

  1. Place the blue plastic nose clip securely over the bridge of the volunteer's nose.
  2. Squeeze gently to close both nostrils.
  3. Breathe out gently against closed lips to test that no air escapes through the nose.
Stop and check
  • Nose clip pads rest gently on the nostrils without pain.
  • The volunteer feels comfortable when they breathe through their mouth.

Careful: If air leaks out through the nose, your volume measurements will be falsely small. Make sure that the nose clip closes nostrils firmly and does not cause pain.

Subject breathing through spirometer while seated with forearms braced

Step 4 of 6

Record sitting breath data

  1. Place the mouthpiece into your mouth. Close your lips tightly around it. Do not block the hole.
  2. On an INHALE, tap Collect and breathe normally for 4 quiet cycles (in and out counts as 1 cycle).
  3. After cycle 4, take the DEEPEST possible inhale. Forcefully blow out ALL air until empty. Take one recovery breath. Tap Stop.
Stop and check
  • Volunteer is seated upright with arms braced.
  • Mouthpiece forms an airtight seal around lips.
  • Teammate is ready to tap Collect on an inhale.
  • The volunteer places lips tightly around the mouthpiece while seated.

Careful: A forced deep breath can sometimes cause slight dizziness. Breathe at a steady pace. If you feel lightheaded, stop immediately and remove the mouthpiece.

Highlighting peak to trough on the breathing graph

Step 5 of 6

Calculate sitting lung volumes

  1. To find Tidal Volume (TV), highlight one normal wave (peak to valley). Tap Graph Tools. Choose View Statistics. Record the height difference (Δy).
  2. Find Vital Capacity (VC). Highlight from top of giant maximum inhale peak to bottom of forced exhale trough. Record Δy.
  3. Calculate Inspiratory Reserve (IRV: maximum peak minus tidal peak) and Expiratory Reserve (ERV: subtract IRV + TV from Vital Capacity).
Stop and check
  • Statistics box is open on the highlighted area.
  • You record Δy values that you round to 0.1 L.

Careful: If you measure peak-to-baseline instead of peak-to-trough, you get half of the actual volume. Always drag your selection from the very top peak down to the bottom valley.

1 more step, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 11, Biology, chapter 14: Breathing and Exchange of Gases
IB Diploma
  • Related Level DP, Biology, chapter B3.1: Gas Exchange

Versions and what each needs

  • Does standing help you breathe more?
    Human Physiology Vol 2, 60 min, Based on a Vernier lab
    Needs: Go Direct Spirometer