Experiments › Human Physiology

Does your blood pressure change all day?

Diurnal BP

Grades 7-8Human Physiology1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

An alarm clock next to morning sunlight and a resting student stretching

Wonder

Does your heart push blood at the exact same pressure every hour?

Show the answer

Your blood pressure naturally rises, dips, and shifts as your body follows its daily clock. Today you will track your personal daily rhythm.

Illustration showing a sunny morning icon transitioning into an evening starry sky

Introduction

Does Your Blood Pressure Change All Day?

When a nurse wraps a cuff around your arm, you get two numbers like 115 over 75. But that reading is only a single snapshot in time. Your body is alive and dynamic! In the morning, hormones surge to help you wake up. In the afternoon, digestion and stress take over. At night, your body winds down. In this experiment, you will measure blood pressure across different hours to discover your body's daily rhythm.

Driving question: Does your blood pressure stay the same all day, or does your body change it on purpose?

What you will learn

Today you will find out

  • I can measure blood pressure safely and accurately with a sensor cuff.
  • I can explain what systolic and diastolic pressure numbers mean.
  • I can describe how blood pressure changes from morning to night.
  • I can explain why one single blood pressure reading cannot diagnose someone.
  • I can link changes in blood pressure to everyday activities and body rhythms.

Why it matters: Millions of people manage blood pressure for lifelong health. Understanding daily body rhythms helps doctors make accurate medical choices.

Safety first

Scientist Rules for Today

  • Educational use only: never use these readings to diagnose or treat health conditions.
  • Blue gloves = student operator. Subject student keeps their arm bare or wears a thin sleeve.
  • Do not over-inflate: never pump the cuff above 200 mmHg.
  • If the subject feels numbness, prickles, or pain, immediately turn the valve counter-clockwise to release all air.
  • Never keep the cuff inflated for more than 90 seconds at a time.
  • Clean the nylon cuff with a disinfectant wipe between different student subjects.

What you need

  • Go Direct Blood Pressure Sensor1 per group
  • Tablet running Graphical Analysis1 per group
  • Disinfectant wipes1 pack per class
  • Small flathead screwdriver1 for teacher · teacher
Tablet screen showing Graphical Analysis connected to the sensor

Step 1 of 6

Connect sensor and set collection time

  1. Connect the Go Direct Blood Pressure Sensor over Bluetooth or USB.
  2. Tap Mode. Set End Collection to 120 seconds. Tap Done.
  3. Tap View and choose Graph and Meter to see live numbers.
Stop and check
  • Tablet Bluetooth is turned on.
  • Sensor battery is charged.
  • Hoses and cables are not tangled.
  • Go Direct Blood Pressure Sensor is powered on with Graphical Analysis open.

Careful: Sensor loses connection if Bluetooth disconnects. Keep the sensor within 2 metres of your tablet.

Student hand fitting the blood pressure cuff 2 cm above partner's elbow

Step 2 of 6

Attach the cuff to the upper arm

  1. Attach the black Luer-lock tube connector to the sensor stem with a half twist.
  2. Wrap the cuff snugly around the subject's upper arm, 2 cm above the elbow crease.
  3. Position the two rubber hoses so they run down over the bicep muscle.
Stop and check
  • The subject wears a short-sleeve shirt or a loose rolled shirt.
  • The arm is relaxed and bare under the cuff.
  • Hoses point downward toward the hand, not twisted.
  • Cuff is snug enough that only two fingertips fit underneath.

Careful: A loose cuff slips during inflation and gives inaccurate readings. Wrap the cuff firmly against bare skin. Center the hoses over the brachial artery along the inner arm.

Forearm resting relaxed on the table with palm up

Step 3 of 6

Position the subject to rest quietly

  1. Have the subject sit comfortably in a chair with back supported and feet flat on the floor.
  2. Rest the subject's arm on the table surface with the palm up.
  3. Position the arm so the cuff is at roughly heart level.
Stop and check
  • Subject has been seated for at least 3 minutes.
  • Forearm rests relaxed on table surface.
  • Room is quiet and calm.
  • The subject must stay completely still and silent. The subject must not talk or move.

Careful: Arm muscle movement or laughter shakes the cuff and spoils data. Subject stays completely relaxed like a statue until measurements finish.

Student hand pumping the rubber bulb as pressure rises to 160 mmHg

Step 4 of 6

Inflate the cuff to 160 mmHg

  1. Tap Collect on Graphical Analysis to begin.
  2. Squeeze the black rubber bulb repeatedly until cuff pressure reaches at least 160 mmHg.
  3. Stop when the sensor light flashes green. Lay the bulb down gently.
Stop and check
  • Partner has hands ready on the squeeze bulb.
  • Subject is relaxed and silent.
  • Check that exhaust valve is closed (finger tight clockwise).

Careful: Cuff pressure above 200 mmHg pinches the arm uncomfortably. Pump steadily, stop immediately when reading reaches 160-170 mmHg and indicator blinks green.

Deflation curve on tablet dropping below 50 mmHg with calculated numbers

Step 5 of 6

Deflate cuff and calculate results

  1. Watch the downward slope on the screen for tiny heartbeat ripples on the line.
  2. Allow pressure to drop below 50 mmHg while the sensor calculates results.
  3. Open the exhaust valve fully to release the rest of the air. Keep the cuff on the arm.
Stop and check
  • The subject stays completely still and does not speak.
  • Nobody bumps the table or hoses.
  • Pressure drops smoothly toward 50 mmHg.
  • Leave the bulb untouched so the built-in valve deflates automatically at 3 mmHg per second.

Careful: Speech or arm muscle movement interrupts pulse wave calculations. Subject breathes normally and keeps arm limp until numbers appear.

1 more step, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 11, Biology, chapter 15: Body Fluids and Circulation
Cambridge AS & A Level
  • Related Level AS & A Level, Biology, chapter 8: Transport in mammals

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.