Experiments › Chemistry
Finding hidden iron with electricity
Potentiometric
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can a liquid chemical reaction create an electric jump?
Show the answer
When two chemicals swap electrons, tiny voltages appear. Today you will catch the exact moment iron finishes reacting by watching a sudden electrical leap.

Introduction
Can You Find Hidden Iron in Clear Water?
Have you ever wondered how scientists measure invisible chemicals in water? You cannot count iron particles with your eyes. But iron particles love to give away tiny electric charges called electrons! In this experiment, we add a yellow liquid that pulls electrons away from iron. An electric sensor watches the reaction. When every bit of iron has reacted, the voltage jumps instantly like an electric shock. By catching that jump, we reveal the hidden iron.
Driving question: Can we find out how much iron is in a liquid by measuring electric jumps?
What you will learn
Today you will find out
- I can explain how swapping electrons creates an electric reading in a liquid.
- I can spot the sudden voltage jump on the reaction graph.
- I can find the exact drop volume where the iron completely finished reacting.
- I can help set up the drop counter and sensor safely.
- I can give examples of how industries use electrical liquid testing.
Why it matters: Water treatment plants, battery factories, and pharmaceutical labs use electric titrations to measure exact chemical quantities safely.
Safety first
Scientist Rules for Today
- Wear splash goggles, protective gloves, and a lab apron at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- The yellow cerium solution contains strong sulfuric acid. An adult must handle and pour it.
- Never taste any chemical and never touch solutions with bare hands.
- Keep all liquid beakers away from the tablet and cables.
- If any liquid splashes on skin, rinse immediately with lots of tap water and tell the teacher.
- Wash your hands fully with soap at the end of class.
What you need
- Go Direct ORP Sensor1
- Go Direct Drop Counter1
- Stir Station1
- plastic 60 mL reagent reservoir1 · teacher
- (NH4)2Fe(SO4)2•6H2O solution30 mL
- 0.100 M (NH4)2Ce(NO3)6 in 1 M H2SO465 mL · teacher
- two 250 mL beakers2
- magnetic stir bar1
- Distilled water wash bottle1
- Splash goggles and nitrile gloves1 set per person

Step 1 of 6
Measure your iron solution into the beaker
- Use a graduated cylinder to measure precisely 30.0 mL of the pale iron test liquid.
- Pour it smoothly into a clean 250 mL glass beaker.
- Slide the small white magnetic stir bar into the beaker gently.
- You wear goggles and light blue gloves.
- The beaker sits flat on the table, not near the edge.
- Graduated cylinder is steady.
Careful: If you drop the stir bar too hard, you can crack the bottom of the glass beaker. Tilt the beaker slightly and slide the stir bar down the side gently.

Step 2 of 6 Teacher does this
Adult sets up and fills the reagent reservoir
- An adult clamps the 60 mL reservoir to the ring stand over a waste beaker.
- The adult carefully pours yellow cerium solution up to the 60 mL mark.
- Drain a tiny splash through the tip to clear out air bubbles.
- The adult wears chemical splash goggles and purple acid gloves.
- Waste beaker is placed directly under the reservoir spout.
- Students stand one step back from the station.
- Make sure that both blue valves are horizontal (closed).
Careful: The yellow liquid contains 1 M sulfuric acid, which can cause severe burns to eyes and skin. Only an adult handles the yellow cerium bottle. Use a small funnel to pour slowly.

Step 3 of 6 Teacher does this
Attach the Drop Counter and align the drops
- Slide the Go Direct Drop Counter onto the Stir Station support rod.
- Line up the drop slot directly under the tip of the reservoir.
- Open the bottom valve. Slowly turn the top valve to 1 drop every 2 seconds. Close the bottom valve.
- The waste beaker rests below the hole of the drop counter.
- The drop counter clamp is tightened firmly so it cannot slip.
Careful: Drops that hit the edge of the plastic slot instead of drop through the hole miss the counter. Look directly down from above. Make sure that the tip aligns with the center of the rectangular window.

Step 4 of 6
Mount the ORP Sensor into the reaction beaker
- Place the beaker with your 30 mL iron solution onto the Stir Station plate.
- Slide the Go Direct ORP Sensor down through the large hole in the Drop Counter until submerged in liquid.
- Turn on the Stir Station knob to stir gently.
- Turn the stir knob fully off before you insert the sensor.
- The sensor glass body is held securely.
- Make sure the sensor is away from the center so the stir bar will not touch it.
Careful: A stir bar that spins can strike the glass electrode tip and shatter it. Position the probe near the side wall of the beaker, clear of the central spin path.

Step 5 of 6 Teacher does this
Start the titration and watch the jump
- Tap Collect in Graphical Analysis.
- The teacher opens the bottom valve so yellow drops begin to fall steadily.
- Close the bottom valve after drops run another 4 to 5 mL past the jump.
- The stir bar spins at a steady fast pace and does not splash.
- The drop rate is about 1 drop every 2 seconds.
- The sensor remains submerged in the liquid.
- Watch the tablet as data points plot automatically with each drop.
- Watch closely as the volume nears 28 to 30 mL to see the huge sudden jump.
Careful: If you let the reservoir run completely dry, the drops stop and bubbles enter. Close the bottom valve when 5 mL past the steep jump, before the reservoir empties.
1 more step, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 11, Chemistry, chapter 1: Redox Reactions
- Direct Class 12, Chemistry, chapter 4: The d- and f-Block Elements
- Direct Level AS & A Level, Chemistry, chapter 7: Redox reactions
- Direct Level AS & A Level, Chemistry, chapter 24: Transition elements
Versions and what each needs
- Finding hidden iron with electricity
Advanced Chemistry, 75 min, Based on a Vernier lab
Needs: Go Direct Drop Counter, Go Direct ORP Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.