Experiments › Physics

Finding the sweet spot for wind power

Effect of Load

Grades 7-8Physics1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Modern wind turbine spinning on a breezy green hill under moving clouds

Wonder

Can plugging in an appliance slow down a giant spinning wind turbine?

Show the answer

Yes! When an electrical load draws power, it creates a magnetic drag inside the generator. Today you find the sweet spot where wind power hits its absolute maximum.

Cyclist shifting gears on a multi-speed bicycle on a road

Introduction

Finding the Sweet Spot for Wind Power

Imagine riding a bicycle. If you pedal with zero gear resistance, your legs spin wildly but you barely move. If you shift into an impossibly high gear, you can hardly push the pedals at all. There is a middle gear where your leg effort turns into the fastest ride. A wind turbine generator works the same way. When connected to an electrical load, the generator pushes electric charges through a resistance. Does more resistance always give more electric power? Today you test a wind turbine across twelve resistance settings to uncover the secret sweet spot of renewable energy.

Driving question: Why does a wind turbine make the most electric power when the circuit is just right?

What you will learn

Goals for this investigation

  • I can explain what an electrical load does in a circuit.
  • I can measure the power output of a spinning wind turbine at different loads.
  • I can spot the peak power resistance on a graph.
  • I can compare the best load resistance to the generator's own resistance.
  • I can explain why renewable energy systems adjust their electrical load.

Why it matters: Power plants, solar homes, and wind farms must tune their electrical loads constantly so no clean energy goes to waste.

Safety first

Lab Rules for Spinning Wind Equipment

  • Wear safety goggles at all times while the box fan or wind turbine spins.
  • Keep faces, hands, and loose hair well away from blades that spin. Never touch blades that spin.
  • Do not stand directly in line with the plane of rotation of the turbine blades.
  • Check that the fan cord does not hang across walkways where someone could trip.
  • Turn off the fan immediately if a blade becomes loose or strikes the tower.
  • Purple gloves = teacher does it. Blue gloves = you do it.

What you need

  • Go Direct Energy Sensor1
  • Vernier Variable Load1
  • KidWind wind experiment kit1 assembled kit
  • electric desk fan1 3-speed box fan
  • cardboard box1 support box
  • electrical wire with alligator clips4 jumper leads (2 red, 2 black)
  • Tablet running Graphical Analysis1 per group
  • digital multimeter1 per classroom
  • safety goggles1 pair per student
Student finger sliding switch on Energy Sensor to External Load

Step 1 of 8

Set switch to External Load and pair sensor

  1. Slide the small toggle switch on the Go Direct Energy Sensor to 'External Load'.
  2. Press the power button on the sensor once. The LED light begins to flash red.
  3. Open Vernier Graphical Analysis on your tablet or laptop.
  4. Connect to your Energy Sensor with Bluetooth. The LED changes and flashes green.
Stop and check
  • Tablet Bluetooth is turned on.
  • Sensor battery is charged.

Careful: If you leave the switch on Internal Load, resistance stays at 30 ohms. Your variable load will not work. Double check that the switch points firmly to External Load.

Wiring connections between turbine, Energy Sensor, and Variable Load box

Step 2 of 8

Wire the turbine and variable load to sensor

  1. Connect the red and black wires from the turbine generator into the Source terminals on the Energy Sensor.
  2. Connect two jumper wires from the External Load terminals of the sensor into the Variable Load box.
  3. Use red for positive (+) and black for negative (-). Keep wires neat and flat on the table.
Stop and check
  • All clip leads are insulated.
  • Turbine fan is not yet turned on.

Careful: Loose clips can fall off during fan vibration and break the electrical circuit. Push plugs all the way into the terminal posts so connections are snug.

Box fan on support box aligned 15 cm from model wind turbine

Step 3 of 8

Align the fan and turbine

  1. Place the box fan on the cardboard riser box so the fan center lines up with the turbine hub.
  2. Position the front face of the fan about 15 cm from the turbine blades.
  3. Make sure that you lock the three turbine blades firmly at identical pitch angles.
  4. Clear away all pens, notebooks, and stray wires from the space around the blades.
Stop and check
  • Everyone has safety goggles on.
  • The bench surface is completely clear of clutter.
  • The turbine base sits flat and does not wobble.

Careful: A blade that spins can hit an object or throw a loose piece of tape across the room. Keep the full rotation circle clear. Never lean over a rotor that spins.

Tablet screen showing positive voltage and current meter readouts during test spin

Step 4 of 8

Test spin and check polarity

  1. Put on your safety goggles. Turn on the fan to low for a brief test spin.
  2. Look at the Voltage and Current meter readings on Graphical Analysis.
  3. If the values are positive, your wire connections are correct. Turn off the fan.
  4. If values show negative numbers, turn off the fan and swap the two Source wires.
Stop and check
  • All group members wear goggles.
  • Nobody stands in the blade rotation plane.

Careful: Reversed wires make the app display negative power values. Turn off the fan before you touch or swap any wires.

Student turning Variable Load knob while tablet records live power data

Step 5 of 8

Set load to 10 ohms and measure power

  1. Turn the fan on to its highest speed. Wait 30 seconds for the rotor to reach full speed.
  2. Turn the knob on the Variable Load box until the Resistance meter reads about 10 Ω.
  3. Tap Collect to record power data for 30 seconds.
  4. Open Graph Tools. Tap View Statistics. Record the mean power value for Trial 1.
  5. Tap Collect again for Trial 2 at 10 Ω. Record the mean power.
Stop and check
  • The fan runs on high and sits stable.
  • Blades spin smoothly and do not hit any wires.
  • Variable Load knob turns smoothly.

Careful: If you collect data before blades reach top speed, you get an artificially low power reading. Always wait the full 30 seconds after you start the fan before you tap Collect.

3 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 12, Physics, chapter 3: Current Electricity
Cambridge AS & A Level
  • Related Level AS & A Level, Physics, chapter 10: D.C. circuits

Versions and what each needs

  • Finding the sweet spot for wind power
    Renewable Energy, 50 min, Based on a Vernier lab
    Needs: Go Direct Energy Sensor