Experiments › Chemistry

Flame fingerprints of metals

Metal Poisoning

Grades 7-8Chemistry1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Campfire flame with glowing red and green sparks

Wonder

Why does tossing different salts into a campfire make green, red, and yellow sparks?

Show the answer

Every metal gives off its own unique colours of light when heated. Scientists call this an emission spectrum, and today you will use it to solve a forensic mystery.

Sports drink bottle in locker room with glowing aura

Introduction

The Mystery in the Locker Room

A sports team found an opened bottle of blue sports drink that tasted strange and salty. Forensic investigators suspect someone accidentally spilled a metal salt into it. Plain chemical tests could not identify the substance, but every element has a hidden secret: when heated in a flame, its atoms glow with their own special colour barcode. Today, you will capture those light barcodes to catch the mystery metal.

Driving question: Can we identify a mystery chemical in a drink by setting it on fire?

What you will learn

Today you will find out

  • I can identify metal flame colours by eye.
  • I can measure light peak wavelengths with an optical fibre and sensor.
  • I can match a mystery liquid's light peak to a known metal.
  • I can explain why metals produce unique light fingerprints.
  • I can describe how glowing metal colours are used in fireworks and science.

Why it matters: Fireworks makers, forensic detectives, and astronomers all use flame colours to identify elements without touching them.

Safety first

Flame and Chemical Safety Rules

  • Wear splash goggles, protective gloves, and a lab apron at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Look for the ADULT NEEDED badge. Only your teacher handles Bunsen burners and open flames.
  • Tie back long hair. Tuck in loose clothes or hoodie strings before you enter the lab.
  • Never taste or sip any liquid in the lab. Do not taste the sports drink samples.
  • Keep test tubes, flammable liquids, and clothes at least 30 cm away from the flame.
  • Never touch the hot nichrome wire with bare fingers; allow it to cool in water.
  • Wash your hands fully with soap and water after the lab.

What you need

  • Go Direct SpectroVis Plus Spectrophotometer1 per station · teacher
  • Emissions / spectrometer optical fibre1 per station
  • laboratory gas burner1 per station · teacher
  • ring stand with clamp1 per station
  • Test tubes and rack8 tubes in 1 rack
  • rubber stopper with glass tube1 nichrome loop assembly
  • 250 mL beaker1 with 150 mL distilled water
  • commercial liquids6 dropper bottles of metal ions
  • blue liquid in a reagent bottle2 bottles (Fresh and Evidence)
  • Tablet running Graphical Analysis1 per station
  • Splash goggles and nitrile gloves1 set per person
Optical fibre clamped to ring stand next to unlit burner

Step 1 of 8

Mount the optical fibre to the ring stand

  1. Attach the utility clamp onto the ring stand rod at burner height.
  2. Clamp the tip of the optical fibre cable securely.
  3. Position the tip horizontal. Keep it about 3 cm away from the flame position.
Stop and check
  • The clamp holds the fibre firmly and does not crush it.
  • The burner gas tap is completely closed.
  • Do not let the fibre touch where the flame burns.

Careful: If the plastic optical fibre touches the flame, it will melt. Keep the fibre tip at least 3 cm away from the flame zone.

Inserting optical fibre adapter into SpectroVis Plus cuvette slot

Step 2 of 8

Plug fibre into the spectrometer

  1. Take the square adapter end of the optical fibre cable.
  2. Insert it firmly into the cuvette slot on top of the SpectroVis Plus.
  3. Keep the sensor placed safely away from the burner area.
Stop and check
  • The sensor sits on a dry table surface.
  • The cable has slack and is not stretched tight.

Careful: Do not pull the cable. A pull can drop the sensor off the bench. Leave plenty of loose cable between the ring stand and sensor.

Rack of 8 labelled test tubes and rinse beaker with water

Step 3 of 8

Prepare the test tubes and rinse beaker

  1. Label 8 test tubes: Na+, Ca2+, Cu2+, Li+, K+, Sr2+, Fresh Drink, and Evidence.
  2. Add about 3 mL of each correct solution into its tube.
  3. Fill the 250 mL beaker with 150 mL of distilled water to rinse the wire.
Stop and check
  • All tubes sit upright in the rack.
  • Each tube label is clearly legible.

Careful: If you mix up droppers, you will cross-contaminate the metal samples. Use only the dropper from each bottle and recap immediately.

Teacher lighting Bunsen burner with striker

Step 4 of 8 Teacher does this

Have an adult light the Bunsen burner

  1. Your teacher checks all connections and lights the Bunsen burner.
  2. The teacher adjusts the air vent to produce a quiet, steady blue flame.
  3. Notice the blue flame has almost no yellow light of its own.
Stop and check
  • Everyone wears safety goggles.
  • Hair is tied back and sleeves are rolled up.
  • No flammable liquids are near the burner.
  • Stand one step back and keep hands clear.

Careful: Open gas flames can burn skin or ignite loose hair and sleeves. Only the adult lights and adjusts the burner. Keep a safe distance.

Nichrome wire in flame producing intense yellow flare and graph spike

Step 5 of 8 Teacher does this

Test the sodium standard (Na+)

  1. Tap Collect on the tablet to start reading light.
  2. Observe the bright yellow-orange flare by eye.
  3. When a sharp peak reaches maximum height on the graph, tap Stop.
Stop and check
  • Wire loop was dipped only in the Na+ tube.
  • The optical fibre tip is still aimed 3 cm from the flame.
  • Dip the clean nichrome loop into the Na+ solution tube.

Careful: Hot wire can cause burns if you touch it before it is cool. The teacher holds the wire handle. Immediately plunge hot wire into rinse water after each test.

3 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

ICSE (CISCE)
  • Related Class 9, Chemistry, chapter 9: Practical Chemistry
IB Diploma
  • Direct Level DP, Chemistry, chapter Structure 1.3: Electron configurations

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.