Experiments › Chemistry

Hidden colours of spinach

Extract Spinach Pigment

Grades 7-8Chemistry1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 11 steps. To run it with the sensors, record data and take the quiz, students use the app.

Fresh green spinach leaves next to vibrant yellow autumn leaves on a clean surface

Wonder

Why do green autumn leaves suddenly turn bright yellow and gold?

Show the answer

Those warm yellow colours were hiding in the leaf the whole time. Green chlorophyll masks them until autumn. Today you extract and separate spinach pigments to uncover the secret colours yourself.

A pestle crushing fresh spinach leaves into dark green juice in a porcelain mortar

Introduction

The Colours Hiding in Plain Sight

Look closely at a bowl of fresh spinach. Every leaf looks deep emerald green. But is that green liquid made of just one chemical? In nature, plants use teams of light-absorbing chemicals called pigments to capture sunshine. Chlorophyll provides the rich green shade, while yellow carotenoids capture extra light. Today you will grind fresh spinach, separate its pigments using chromatography, and scan them with a light sensor to find out exactly which rainbow colours each pigment swallows.

Driving question: Are spinach leaves really only green, or are other colours hiding inside?

What you will learn

Today you will find out

  • I can explain why leaves have both green and yellow pigments.
  • I can explain how chromatography separates different colours in a mixture.
  • I can calculate how far a spot travelled compared to the solvent front.
  • I can find the peak light wavelengths absorbed by yellow and green pigment solutions.
  • I can follow safety steps for organic liquids and hot water baths.

Why it matters: Botanists, food chemists, and solar energy engineers study plant pigments to build better crop varieties, detect spoiled food, and design solar panels that capture sunlight just like leaves.

Safety first

Safety Rules for Plant Extraction

  • Wear safety goggles, chemical-resistant gloves, and a long-sleeved lab coat at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Acetone and hexane are flammable and give off strong fumes. An adult must handle them in a fume hood.
  • Keep solvents far away from open flames, hot plates, and electrical outlets.
  • Do not inhale silica powder. Keep all silica work inside the fume hood.
  • Never taste or drink any liquid from this lab. Wash hands fully with soap after cleanup.

What you need

  • fresh plant leaves1.0 g fresh spinach leaves
  • mortar and pestle1 set
  • Digital balance (0.01 g precision)1 per classroom
  • Go Direct SpectroVis Plus Spectrophotometer1 per station · teacher
  • Go Direct Temperature Probe1 per station
  • Plastic cuvette (4 clear sides)2 glass cuvettes with caps
  • blank paper index card1 silica TLC plate (2.5 x 7.5 cm)
  • laboratory hot plate1 in fume hood · teacher
  • 250 mL beaker1 x 250 mL and 1 x 400 mL
  • Test tubes and rack6 small test tubes in rack
  • ring stand with clamp1 stand with utility clamp · teacher
  • clear solution in a reagent bottleAcetone, hexane, Na2SO4, silica, sand · teacher
Student weighing torn spinach leaves on an electronic balance

Step 1 of 11

Weigh the spinach leaves

  1. Place a piece of weigh paper on the digital balance. Press zero (tare).
  2. Add leaf pieces onto the balance until you reach about 1.0 g.
  3. Record the exact mass in your data notebook.
Stop and check
  • The balance is on a level, stable bench.
  • Students wear light blue gloves.
  • Tear fresh spinach leaves into small pieces without thick stems.

Careful: Drafts or pressure on the balance pan can cause incorrect mass readings. Place leaf pieces gently. Wait until the balance display settles.

Grinding spinach leaves with solvents in a mortar inside a fume hood

Step 2 of 11 Teacher does this

Add solvent and grind leaves

  1. Place the torn spinach leaves inside the porcelain mortar.
  2. In the fume hood, have the adult add 3 mL of acetone and 3 mL of hexane.
  3. Grind the leaves firmly with the pestle for 3 to 5 minutes.
Stop and check
  • The fume hood sash is at the safe work height.
  • The adult wears purple gloves and safety goggles.
  • No open flames or heat sources are nearby.

Careful: Acetone and hexane release flammable vapours that can irritate eyes and cause dizziness if inhaled. Only the adult measures and pours solvents. Keep the mortar strictly inside the active fume hood.

A test tube showing two separated liquid layers: green organic layer on top and clear salt water below

Step 3 of 11 Teacher does this

Filter and wash the green extract

  1. In the hood, have the adult filter the green liquid through a cotton-plugged pipet into a clean test tube.
  2. Add 2 mL of saturated salt water (aqueous sodium chloride) to wash the solution.
  3. Stand the tube in the rack until two distinct liquid layers separate.
Stop and check
  • Adult wears purple gloves and goggles.
  • Vent the stopper immediately after you shake it gently to prevent pressure buildup.
  • Vent the stopper immediately after you shake it gently to release gas pressure.

Careful: Pressure buildup from solvent vapours can pop the stopper and spray chemicals. Point the open tube away from everyone. Loosen the stopper gently to vent.

A test tube with dark green extract resting in a warm water bath with a Go Direct Temperature Probe

Step 4 of 11 Teacher does this

Dry and gently concentrate the extract

  1. Work inside the hood. Have the adult filter the upper green layer through a pipet half-filled with sodium sulfate into a clean tube.
  2. Place the tube in a warm water bath. Keep the bath at 70°C with the Go Direct Temperature Probe.
  3. Evaporate the solvent until only 0.2 to 0.3 mL of concentrated dark green extract remains.
Stop and check
  • Water bath temperature is monitored and does not exceed 75°C.
  • Work remains entirely inside the chemical fume hood.
  • Put a boil stone into the tube before you heat it.
  • Add one small ceramic boil stone to keep the liquid at a smooth boil without splash.

Careful: Hexane boils at 69°C. Too much heat can cause a sudden boil and splash of flammable organic solvent. Keep bath strictly around 70°C; remove tube as soon as volume shrinks to about 0.2 mL.

Student hand spotting a TLC plate with a glass capillary tube

Step 5 of 11

Prepare and spot the TLC plate

  1. With a pencil and ruler, draw a light line 1.0 cm from the bottom of the silica plate (the origin).
  2. Dip the thin glass capillary tube into your concentrated green extract.
  3. Touch the tip gently onto the pencil line to make a small spot 1 to 2 mm wide. Let it dry.
Stop and check
  • Handle the TLC plate only by the top edges so fingers do not scrape off the silica.
  • Make spots on a dry, clean paper towel surface.
  • Never use an ink pen: ink contains dyes that will dissolve and ruin your results.

Careful: Too much pressure from the pencil or glass tube can scrape off the white silica layer. Touch the plate very lightly; keep the green spot tiny (under 2 mm).

6 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 11, Biology, chapter 11: Photosynthesis in Higher Plants

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.