Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 9 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
If two clear liquids are totally mixed, can you pull them apart with heat?
Show the answer
Yes! Because different liquids boil at different temperatures, the lower-boiling liquid turns to gas first. Today you will catch that gas, chill it back to liquid, and measure how pure it is.

Introduction
How Can Boiling Separate Mixed Liquids?
When salt dissolves in water, you can boil off the water and leave dry salt behind. But what happens if two liquids are blended together, like ethanol and water? They both want to evaporate! Luckily, ethanol boils at 79 degrees Celsius, while water boils at 100 degrees Celsius. In this lab, we boil the blend, send the hot gas through a cold water jacket, and collect three separate liquid batches called fractions. By tracking temperature and weighing each batch, you will see how boiling sorts out mixed molecules.
Driving question: Can we separate two mixed liquids just by boiling them?
What you will learn
Today you will find out
- I can explain how boiling separates liquids with different boiling points.
- I can find the boiling point plateau on a temperature graph.
- I can calculate density to tell which liquid came out first.
- I can follow safety rules around hot apparatus and flammable liquids.
- I can connect distillation to fuel refining and water purification.
Why it matters: Distillation is how petrol is refined from crude oil, how perfume scents are captured from flowers, and how seawater is made drinkable on ships.
Safety first
Scientist Rules for Today
- Wear splash goggles, protective gloves, and a lab apron at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Ethanol liquid and vapor are highly flammable. Keep all open flames away from the lab.
- Denatured ethanol is poisonous. Never smell, taste, or ingest any liquids or distillates.
- Look for the ADULT NEEDED badge. The teacher pours ethanol and handles hot plate dials and hot glassware.
- Keep cold water at a gentle flow through the condenser before you turn on the heat.
- Keep the probe wire clamped high up, away from hot plate surfaces.
What you need
- Go Direct Temperature Probe1
- Tablet running Graphical Analysis1
- laboratory hot plate1 · teacher
- 500 mL Erlenmeyer flask1
- glass condenser column1 with 2 hoses · teacher
- ring stand with clamp2 stands, 3 utility clamps
- 100 mL beakers3 (labelled 1, 2, 3)
- 50 mL graduated cylinder1
- 100 mL graduated cylinder1
- clear solution in a reagent bottle60 mL denatured ethanol (95%) · teacher
- ceramic boiling stones3 to 4 chips
- Digital balance (0.01 g precision)1 per group
- rubber stopper with glass tube1 bent tube, 2-hole stopper, 1-hole stopper · teacher
- Splash goggles and nitrile gloves1 set per student and teacher

Step 1 of 9 Teacher does this
Assemble the distillation stands and condenser
- Set up two sturdy ring stands side by side on your bench.
- Place the hot plate on the base of the left ring stand, turned completely off.
- Clamp the 500 mL flask on the left stand directly above the hot plate.
- Clamp the glass condenser on the right stand so it slopes gently downward.
- Connect the bottom hose of the condenser to the cold water tap. Put the top hose into the sink.
- Both ring stands feel heavy, stable, and wobble-free.
- Condenser clamps are snug with rubber pads, not overtightened on glass.
- Drain hose points securely down the sink drain so water will not spray.
Careful: Overtightened metal clamps can crack delicate glassware. Loose clamps can drop heavy apparatus. Tighten clamps finger-tight until snug. Never force glass joints. An adult must make sure that all clamps hold.

Step 2 of 9 Teacher does this
Measure liquids and add boiling chips
- Measure 60 mL of tap water in your 100 mL graduated cylinder. Pour the water into the flask.
- Add 3 to 4 ceramic boiling chips into the flask.
- The teacher carefully measures 60 mL of denatured ethanol and adds it to the flask.
- Swirl gently once so the two liquids mix completely.
- Hot plate is completely OFF and cool to the touch.
- Teacher has the denatured ethanol bottle and pours it.
- The ceramic chips are inside before heat begins.
Careful: Denatured ethanol is flammable and toxic. Chips in hot liquid cause a sudden violent boil. Only the adult measures and pours ethanol. Always put boiling chips in while liquid is cold.

Step 3 of 9 Teacher does this
Insert stoppers, tube, and temperature probe
- Insert the bent glass tube through the 2-hole stopper into the flask neck.
- Carefully push the Go Direct Temperature Probe through the second hole of the stopper.
- Position the probe tip in the neck vapor space just beside the side-tube hole.
- Connect the bent glass tube into the upper end of the condenser with the 1-hole stopper.
- Clamp the probe wire to the top of the ring stand, far away from the hot plate surface.
- Stoppers fit tight and airtight in both flask and condenser.
- The metal probe tip is in the gas vapor zone, not down in the liquid.
- The probe wire hangs well clear of the hot plate surface.
Careful: Vapor escapes if stoppers leak. Probe cord can melt and short-circuit if it touches the hot plate. An adult examines both rubber stoppers. Clamp the sensor wire high up on the rod with a third utility clamp.

Step 4 of 9
Place Beaker 1 and turn on cooling water
- Write labels 1, 2, and 3 on your three 100 mL beakers.
- Place Beaker 1 directly below the bottom drip tip of the condenser.
- Slowly open the cold water tap so water flows steadily up through the condenser jacket.
- Make sure that the drain hose discharges smoothly into the sink without splashes.
- Beaker 1 is clean, dry, and upright under the condenser drip tip.
- Water jacket is completely full of water with no large air bubbles trapped inside.
- Table around the sink is dry.
Careful: Water pressure too high can pop hoses off and flood the bench. Drops miss the beaker if misaligned. Turn the tap on slowly to a gentle trickle. Align Beaker 1 right under the drip tip.

Step 5 of 9 Teacher does this
Adult starts heating and students start data collection
- Have the teacher check the entire apparatus one final time.
- Tap 'Collect' in Graphical Analysis to record temperature.
- The teacher turns the hot plate to its high setting to start the heat.
- Watch the temperature climb on the screen. At 50°C, the teacher turns the hot plate down to medium.
- The teacher examined all clamps, stoppers, and cold water flow.
- Goggles are on everyone's face.
- No flammable open flames or loose paper anywhere near the hot plate.
Careful: The hot plate surface reaches over 200°C. A rapid boil can foam over if heat stays too high. Only the teacher touches the hot plate knob. Turn down to medium at 50°C to keep the boil smooth.
4 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 11, Chemistry, chapter 2: Organic Chemistry: Some Basic Principles and Techniques
- Direct Class 7, Chemistry, chapter 5: Separation Techniques for Components of a Mixture
- Related Level AS & A Level, Chemistry, chapter 17: Alcohols, esters and carboxylic acids
- Direct Level AS & A Level, Chemistry, chapter 18: Carbonyl compounds
- Direct Level DP, Chemistry, chapter Structure 1.1: Introduction to the particulate nature of matter
Versions and what each needs
- How can boiling separate mixed liquids?
Chemistry with Vernier, 60 min, Based on a Vernier lab
Needs: Go Direct Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.