Experiments › Chemistry
How can heat separate mingled liquids?
Fractional Distillation of Esters
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can you unmix two clear liquids that look completely blended together?
Show the answer
Every pure substance turns from liquid to vapor at its own boiling point. By heating the mixture slowly in a special climbing column, we can catch each pure vapor one at a time.

Introduction
Unmixing Blended Liquids
Imagine two clear liquids mixed into one smooth blend. They look identical, but each liquid boils at a different temperature. Ethyl acetate boils at 77°C, while butyl acetate boils at 126°C. If we warm them gently, the one with the lower boiling point evaporates first. Today, we watch a fractionating column separate them drop by drop. Then, a gas chromatograph tests each fraction to prove how pure it really is.
Driving question: How can heating a blended liquid allow you to pull its ingredients apart?
What you will learn
Today you will find out
- I can explain how heating separates liquids with different boiling points.
- I can describe why a tall column gives cleaner separation than a simple flask.
- I can record vapor temperatures as drops distill into graduated cylinders.
- I can read gas chromatography peaks to see which ester distilled first.
- I can name real industries that rely on fractional distillation.
Why it matters: Petroleum refineries, perfume makers, and medicine factories use fractional distillation every single day to purify valuable chemicals.
Safety first
Laboratory Safety Protocol
- Wear splash goggles, chemical-resistant gloves, and a buttoned lab coat at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Ethyl acetate and butyl acetate are flammable and have strong vapors. Work only inside a fume hood that runs.
- Look for the ADULT NEEDED badge. The teacher must do high-heat steps and assemble the glassware.
- The heat mantle and glassware reach temperatures above 130°C. Never touch hot glass with bare hands.
- Never let the distillation flask boil dry. Dry glass can crack under direct heat.
- Handle the 1 µL syringe with extreme care: its metal needle is sharp and the plunger bends easily.
- Wash your hands fully with soap and water before you leave the laboratory.
What you need
- fractional distillation apparatus1 complete setup · teacher
- heating mantle1 with controller · teacher
- Go Direct Wide Range Temperature1 · teacher
- Go Direct Mini GC1 · teacher
- 1 µL glass syringe1 · teacher
- 10 mL graduated cylinders5
- 50:50 ethyl acetate and butyl acetate20 mL in sealed vial · teacher
- boiling stone1 piece
- Parafilm®5 squares
- protective lab gloves1 pair per person

Step 1 of 8 Teacher does this
Assemble the distillation glassware
- Clamp the round bottom flask firmly into the heat mantle inside the fume hood.
- Attach the vertical column packed with glass beads directly above the flask.
- Fit the top distillation adapter. Connect the slanted condenser so cold water enters the bottom and exits the top.
- The fume hood blower is turned on and runs.
- Glass joints are snug and securely clamped without strain.
- Water hoses are tight and drain freely into the sink.
Careful: Glassware can slip and shatter, or loose water hoses can spray the lab bench. Support all heavy glassware with ring stand clamps. Check water flow gently.

Step 2 of 8 Teacher does this
Add the liquid mixture and boiling stone
- Measure 20 mL of 50:50 ethyl acetate and butyl acetate blend. Pour it carefully into the flask with a funnel.
- Add one ceramic boil stone into the flask to keep the boil smooth.
- Reconnect the flask tightly to the bottom of the fractionation column.
- The heat mantle is unplugged and completely cold before you add liquid.
- A boil stone is inside the flask before heat starts.
- Funnel is wiped dry.
Careful: If you add a boil stone to hot liquid, violent boil action and liquid eruption can occur. Always add the boil stone while the liquid is cold. Never add stones to hot liquid.

Step 3 of 8 Teacher does this
Position the temperature probe and prepare cylinders
- Insert Go Direct Wide Range Temperature probe through the adapter stopper level with the sidearm port.
- Label five clean 10 mL graduated cylinders with numbers 1 to 5.
- Place cylinder 1 beneath the condenser drip tip to catch the first distillate.
- Probe tip is suspended in the vapor path and does not touch glass walls.
- Collection cylinder 1 sits stably below the vacuum drip adapter.
- Parafilm squares are ready on the bench.
Careful: If the probe touches glass, it reads glass temperature instead of vapor temperature. Make sure that the probe tip hangs freely in the center of the sidearm junction.

Step 4 of 8 Teacher does this
Start heating and begin temperature logging
- Switch on the heat mantle. Turn the dial to a moderate setting.
- Tap Collect on Graphical Analysis to record vapor temperature.
- Watch the liquid warm for bubbles near the boil stone. Watch vapor rise up the packed column.
- Condenser water flows smoothly.
- Heat mantle power cord is clear of hot surfaces.
- Fume hood sash is lowered to the safety line.
Careful: Excess heat can flood the column with hot liquid instead of gentle vapor. Warm steadily. If liquid rushes into the column, lower the heat setting promptly.

Step 5 of 8 Teacher does this
Collect five fractions in order
- Adjust heat so distillate drops at about 1 drop per second into cylinder 1.
- Collect ~0.5 mL in cylinder 1, swap in cylinder 2, and seal cylinder 1 with Parafilm.
- Collect ~2 mL in cylinder 2, ~4 mL in cylinder 3, ~3 to 4 mL in cylinder 4, ~3 mL in cylinder 5, logging temperatures.
- All five cylinders are nearby and labeled 1 through 5.
- Parafilm is ready to seal each cylinder immediately to prevent evaporation.
- Liquid remains in the flask at all times.
- Never let the flask boil completely dry.
Careful: If the flask boils dry, the glassware can crack and residues can decompose. Stop heat when about 1 to 2 mL of liquid remains in the flask.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 11, Chemistry, chapter 2: Organic Chemistry: Some Basic Principles and Techniques
- Related Level AS & A Level, Chemistry, chapter 30: Analytical chemistry
Versions and what each needs
- How can heat separate mingled liquids?
Organic Chemistry, 90 min, Based on a Vernier lab
Needs: Go Direct Mini GC, Go Direct Wide-Range Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.