Experiments › Physics / Renewable Energy
How can sunlight heat water?
Solar Thermal Energy and Surface Absorption
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does water inside a black garden hose get so hot in the sun?
Show the answer
Dark surfaces swallow light rays and turn radiant energy into thermal energy. Today you will measure how colours reflect and absorb light, then build a working solar water heater.

Introduction
Catching the Sun's Heat
Heating water in our homes uses huge amounts of electricity and fossil fuels. But the Sun showers Earth with free, clean radiant energy every single day. Have you ever noticed how searing hot a dark asphalt road gets compared to white pavement? Solar thermal collectors use this exact secret. By choosing the best colour to swallow sunlight, we can heat flowing water for showers, washing, and home heating without burning a single lump of coal.
Driving question: How can the colour of a surface help sunlight heat your shower water?
What you will learn
Today you will find out
- I can measure how much light different colours reflect and how warm they get.
- I can calculate which surface reflects the most and least light.
- I can explain why black absorber plates make solar water heaters hotter.
- I can build a working solar water heater model and track its temperature rise.
- I can describe how rooftop solar water heaters save fossil fuels and energy costs.
Why it matters: Heating water accounts for nearly 20% of home energy bills. Clean solar thermal systems cut pollution and save money.
Safety first
Scientist Rules for Today
- Wear safety goggles and lab gloves throughout the experiment.
- Purple gloves = teacher does it. Blue gloves = you do it.
- The 100 W lamp bulb gets very hot! Never touch the bulb with bare hands or gloves.
- Keep all water beakers and damp tubes away from the lamp socket and power cables.
- Make sure that the red and black alligator clips do not touch each other. This prevents short circuits.
- Wipe up any spilled water immediately with paper towels.
What you need
- Go Direct Light and Color Sensor1
- Go Direct Temperature Probe1
- Tablet running Graphical Analysis1
- KidWind solar thermal kit1 set
- ring stand with clamp1 stand with 2 clamps
- desk lamp with light bulb1 lamp with 100 W bulb · teacher
- sheet of colored paper1 black sheet, 1 white sheet
- sheet of aluminum foil1 sheet (10 x 10 cm)
- roll of tape and ruler1 roll tape, 1 ruler
- 400 mL beaker with water1 beaker with 300 mL water

Step 1 of 8
Set up the temperature probe on the table
- Tape the cable of the Temperature Probe securely to the table surface.
- Gently bend the tip of the probe slightly upward so it does not touch the tabletop.
- If the tip touches the wood, it measures the table temperature instead of the paper!
- Table is clean and completely dry.
- Tape is ready to secure the wire.
Careful: The delicate probe tip could get crushed if pressed down hard. Bend the wire gently without sharp creases. Secure only with tape.

Step 2 of 8 Teacher does this
Position paper, light sensor, and lamp
- Slide the white paper square over the probe tip. Clamp the light sensor 5 cm above the paper.
- Clamp the Light Sensor on the ring stand exactly 5 cm above the paper. Point the sensor down.
- Clamp the 100 W lamp on top of the ring stand. Point the lamp down at the paper.
- The ring stand is sturdy and will not tip over.
- The lamp cord is untangled and clear of paths.
- Adult confirms clamp tightness.
- Ask your teacher to examine the stand setup before you plug in the lamp.
Careful: The lamp bulb gets very hot and can burn hands or scorch paper if placed too close. Keep the lamp at least 15 cm above the paper. Never touch the bulb.

Step 3 of 8
Test white paper under the lamp
- Switch on the lamp and immediately tap Collect in Graphical Analysis.
- Watch the graph for 10 minutes, then turn off the lamp.
- Record the Minimum Temp, Maximum Temp, and Mean Illuminance (lux) from Graph Tools > View Statistics in Part I data table.
- White paper covers the probe tip completely.
- No hands or paper touch the hot lamp.
- Confirm the white paper is in place over the probe tip and the light sensor is 5 cm above it.
Careful: If you touch the lamp shade, you can get painful burns. Turn on the lamp with the inline switch only. Do not touch the metal shade.

Step 4 of 8
Test black paper and aluminium foil
- Repeat the 10-minute test with the black paper square. Record your statistics.
- Repeat the 10-minute test with the aluminium foil square. Record your statistics.
- Calculate the temperature change. Subtract Start Temp from Final Temp for each sample.
- The probe cools before you place the next sheet.
- Aluminium foil is smooth and not heavily crumpled.
- Wait 2 minutes for the probe to cool back to room temperature.
Careful: The black paper gets noticeably hot after 10 minutes. Pick up the paper by the corner with gloved fingers. Turn off the lamp between runs.

Step 5 of 8
Calculate percent reflectivity
- For each paper, calculate: (Paper Lux / Foil Lux) x 100 = Percent Reflectivity.
- Check sample data: (372 lux / 2558 lux) x 100 = 14.5% for black paper.
- Notice the rule: lowest reflectivity = greatest heat absorption!
- All lux values are written down.
- Calculators or tablet ready for calculations.
- Aluminium foil acts as our standard with an assigned reflectivity of 100%.
Careful: If you divide the numbers backward, you will get a percentage over 100%. Divide the paper lux by the foil lux, then multiply by 100.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 8, Science, chapter 10: Light: Mirrors and Lenses
Versions and what each needs
- How can sunlight heat water?
Renewable Energy, 80 min, Based on a Vernier lab
Needs: Go Direct Light and Color Sensor, Go Direct Surface Temperature Sensor, Go Direct Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.