How clean is that water?
Pollution
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 4 of its 4 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can water look crystal clear and still be dangerous to fish?
Show the answer
Yes! Clear water can lack oxygen, carry invisible salts, or be too acidic. Today you test water health like an environmental scientist.

Introduction
The Invisible Clues in Water
When you look at a river, you cannot always see pollution. Harmful dissolved chemicals are completely invisible to human eyes. Fish need dissolved oxygen gas to breathe, and balanced chemical levels to survive. In this lab, you use digital environmental probes to uncover hidden clues about water health.
Driving question: Can sparkling clear water actually be polluted?
What you will learn
Goals for This Lab
- I can test water samples using digital environmental sensors.
- I can explain why fish need dissolved oxygen to survive.
- I can identify clues that show runoff or pollutants in water.
- I can judge if a water sample meets healthy environmental standards.
Why it matters: Clean water keeps wildlife alive and protects our drinking supply from dangerous contaminants.
Safety first
Water Testing Safety Rules
- Wear safety goggles, lab aprons, and nitrile gloves at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Never taste or drink any water sample tested in the laboratory.
- Keep tablet devices at least 30 centimetres away from water beakers.
- Handle delicate glass pH sensor tips and plastic optical caps with care.
- Wash your hands fully with soap. Use clean water after the lab.
What you need
- Go Direct Optical Dissolved Oxygen Probe1
- Go Direct Conductivity Probe1
- Go Direct pH Sensor1
- Go Direct Temperature Probe1
- Go Direct Turbidity Sensor1
- 250 mL beaker2
- Distilled water wash bottle1
- Plastic cuvette (4 clear sides)1
- Tablet running Graphical Analysis1

Step 1 of 4
Connect your probes to Graphical Analysis
- Press the power button once to turn on each Go Direct probe.
- Open Graphical Analysis on your tablet. Tap Sensor Data Collection.
- Connect the Optical DO, Conductivity, pH, Temperature, and Turbidity probes with Bluetooth.
- Table surface is dry and free of clutter.
- Probes rest safely and do not roll.
Careful: Probes can roll off the bench and crack if dropped. Lay probes flat on the bench. Point them away from table edges.

Step 2 of 4
Rinse probe tips with distilled water
- Hold each probe over an empty waste beaker.
- Use your distilled water wash bottle to gently rinse each sensor tip.
- Blot gently with a clean tissue wipe. Never rub the glass pH bulb.
- Waste beaker is positioned securely under the probe tips.
- You use distilled water, not tap water.
Careful: If you rub hard, you can scratch sensitive optical caps or break thin glass bulbs. Rinse gently with a stream of distilled water. Dab lightly with soft wipes.

Step 3 of 4
Measure dissolved oxygen, temperature, conductivity, and pH
- Place the tips of all four probes into your 250 mL water sample beaker.
- Gently stir the water once with the temperature probe and tap Collect.
- Wait 60 seconds for numbers to stabilize. Record the final steady reading for each sensor in your table.
- Beaker is stable in the centre of the table.
- Probe cables do not pull or tilt the beaker.
Careful: If you tilt probes, you can knock over the beaker and spill water. Hold probes gently or support them so the beaker remains steady.

Step 4 of 4
Measure turbidity with the cuvette
- Rinse a clean plastic cuvette with a small amount of your water sample, then empty it.
- Fill the cuvette three quarters full with the water sample and screw the cap on.
- Wipe the clear outside walls with a lint-free tissue. Insert into the Go Direct Turbidity Sensor. Record the NTU reading.
- The outside of the cuvette is completely dry.
- Cuvette cap is screwed on tightly.
Careful: Fingerprints, water drops, or bubbles scatter light and cause false high readings. Hold only by the cap. Wipe clear sides dry. Tap gently to remove air bubbles.
0 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 10, Biology, chapter 15: Pollution
- Related Level DP, Environmental Systems and Societies, chapter 4: Water and aquatic food production systems and societies
Versions and what each needs
- How clean is that water?
Environmental Science, 60 min, Based on a Vernier lab
Needs: Go Direct CO2 Gas Sensor, Go Direct Conductivity Probe, Go Direct Optical Dissolved Oxygen Probe, Go Direct pH Sensor, Go Direct Soil Moisture Sensor, Go Direct Temperature Probe, Go Direct Turbidity Sensor, Go Direct Weather (sensor only)
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.