Experiments › Environmental Science
How clean is your air?
Particulate Matter and Air Quality
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Is the air around you completely clean, or is it carrying hidden dust and soot?
Show the answer
Even clear air carries tiny floating specks of soot, dust, and pollen. Scientists call them particulate matter, and today you will measure them.

Introduction
How Clean Is Your Air?
Even when the air looks clean, it holds floating specks called particulate matter. Smoke, car exhaust, and soil dust drift through our streets and homes. In this lab, you trap these invisible particles on sticky tape strips over one week. Then you shine light through the tape into a light sensor to measure how much light the trapped dirt blocks.
Driving question: Can we trap invisible air pollution on sticky tape and measure it with light?
What you will learn
Today you will find out
- I can explain what airborne particulates are and how they affect light.
- I can record illumination values for different test card windows.
- I can calculate percent transmittance to find which location had the dirtiest air.
- I can make and handle particulate test cards without contaminating the tape.
- I can position optical test gear safely around a hot incandescent lamp.
- I can identify real-life sources of particulate air pollution in my neighbourhood.
Why it matters: Breathing airborne soot causes asthma, allergies, and lung damage. Measuring dust helps communities clean up city air.
Safety first
Scientist Rules for Today
- Wear safety goggles and lab gloves when you assemble and test cards.
- Purple gloves = teacher does it. Blue gloves = you do it.
- The 100 W bulb gets very hot during tests. Never touch the glass bulb.
- Look for the ADULT NEEDED badge. Only an adult clamps and plugs in the lamp.
- Do not touch the sticky tape windows with bare fingers or gloves.
- Keep mains cables neatly tucked so nobody trips over them.
- Wash your hands with soap after you handle outdoor cards.
What you need
- Go Direct Light and Color Sensor1
- Tablet running Graphical Analysis1
- blank paper index card2 strips (2.5 x 8 inch)
- roll of tape1 roll clear packing tape
- ring stand2
- utility clamp2
- desk lamp with light bulb1 with 100 W bulb · teacher
- scissors1 pair
- metal coin1
- plastic transfer pipet1 one-hole punch
- piece of string40 cm total
- resealable plastic bag1 airtight box or bag
- ruler1 30 cm ruler

Step 1 of 8
Construct two particulate test cards
- Draw four coin circles on an index card strip (6.4 x 20.3 cm). Label them A, B, C, and D with pencil.
- Carefully cut out each circle with scissors.
- Repeat this on a second card so you have two identical cards.
- Scissors have blunt tips.
- Cut away from your fingers on a flat table.
- Both cards are cut to the same size.
Careful: Scissors can slip and cut skin or tear the paper card. Work slowly. Keep your other hand away from the scissor blades.

Step 2 of 8
Apply clear tape and strings
- Cover the back of all four holes with one long strip of clear tape. Position the sticky side outward through the front.
- Punch a hole at the top of each card and thread a 20 cm piece of string through.
- Tie a knot in the string so you can hang the card.
- Gloves are clean and completely dry.
- The tape strip is flat without wrinkles.
- Strings are tied securely.
- Do NOT touch the sticky tape inside the holes with your fingers.
Careful: Fingerprints or wrinkles on the tape block light and ruin your baseline data. Hold the tape by its outer edges only. Smooth it onto the card from behind.

Step 3 of 8
Deploy test card and store control
- Label Card 1 with today's date and 'Control'. Put it immediately inside an airtight box or sealed bag.
- Label Card 2 with today's date and your chosen test location (for example 'Roadside' or 'Kitchen').
- Hang Card 2 where it will not get wet or disturbed. Keep both cards untouched for exactly 7 days to collect air particles.
- The control bag is sealed completely airtight.
- The test location is sheltered from direct rain.
- The sticky side of the card faces open circulating air.
Careful: Rain will dissolve the card, and curious people might touch the sticky windows. Hang the card under an overhang or porch roof, out of direct reach.

Step 4 of 8
Retrieve cards and connect sensor
- After 7 days, get your test card. Bring it and the sealed Control card to your bench.
- Switch on the Go Direct Light and Color Sensor. Open Graphical Analysis on your tablet.
- Pair the sensor with Bluetooth. Select the Visible Light channel (Illumination in lux).
- The cards are flat and the sticky sides face up.
- Sensor battery is charged (green LED).
- Tablet Bluetooth is turned on.
- Do not touch the tape on the cards.
Careful: If you touch the exposed card, you transfer skin oil and spoil 7 days of collection. Hold the test cards only by their paper cardboard edges.

Step 5 of 8
Zero the light sensor
- Cover the tip of the light sensor completely with a piece of dark cardboard or your gloved hand.
- In Graphical Analysis, tap the sensor meter and select 'Zero'.
- Confirm that the reading on your tablet screen now reads 0 lux.
- The sensor tip is completely covered.
- Room light cannot leak into the front window.
- Make sure that zero light reaches the front aperture.
Careful: Light that enters when you set zero causes all future readings to be too low. Cup your gloved hand firmly over the tip until the live reading drops to near zero before you tap Zero.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 6, Science, chapter 11: Nature’s Treasures
- Related Class 7, Science, chapter 9: Life Processes in Animals
- Related Class 8, Science, chapter 3: Health: The Ultimate Treasure
- Direct Class 8, Science, chapter 8: Nature of Matter: Elements, Compounds, and Mixtures
- Related Class 10, Science, chapter 10: The Human Eye and the Colourful World
- Direct Level DP, Environmental Systems and Societies, chapter 6: Atmospheric systems and societies
Versions and what each needs
- How clean is your air?
Environmental Science, 80 min, Based on a Vernier lab
Needs: Go Direct Light and Color Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.