Experiments › Chemistry
How do cold packs work?
Endothermic Dissolution of Urea
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
How can a bag get freezing cold without putting it in a freezer?
Show the answer
When you pop the water bag inside a cold pack, solid crystals dissolve. Separating those particles swallows heat from the water. Scientists call this an endothermic process.

Introduction
Instant Cold Without a Freezer
When a footballer twists an ankle, the team medic snaps a plastic cold pack. Within five seconds, the pack turns icy cold. There are no ice cubes inside and no batteries. Inside the pouch is just dry white powder and a pouch of water. When you squeeze the bag, the water and crystals mix. In this experiment, you will mix urea crystals with water and measure how fast heat disappears from the liquid.
Driving question: How can two room-temperature substances get icy cold just by mixing together?
What you will learn
Today you will find out
- I can explain why dissolving urea makes water turn cold.
- I can record the starting and lowest temperature to find the temperature drop.
- I can classify a cooling dissolution as an endothermic process.
- I can build the test cup setup and use a magnetic stirrer safely.
- I can explain how first-aid cold packs work without ice.
Why it matters: Sports doctors, emergency paramedics and chemists rely on instant chemical cooling to reduce swelling and preserve medicine.
Safety first
Lab Rules for Today
- Wear chemical splash goggles and protective gloves throughout the activity.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Urea is non-hazardous, but never taste, eat, or inhale chemical powders.
- Keep water away from power sockets and tablet screens.
- Make sure that the magnetic stir bar spins smoothly and does not hit the sensor shaft.
- Wash your hands fully with soap and water after cleanup.
What you need
- Go Direct Temperature Probe1
- Stir Station1
- Electrode Support1
- magnetic stir bar1
- 400 mL beaker1
- foam cup1
- 50 mL graduated cylinder1
- Digital balance (0.01 g precision)1 shared
- white chemical powder10.0 g
- water50 mL
- Tablet running Graphical Analysis1

Step 1 of 6
Weigh your sample of urea
- Press the Zero or Tare button so the display reads 0.00 g.
- Use a clean spatula to add about 10.0 g of solid urea crystals.
- Write down the exact mass to the nearest 0.01 g in your notebook.
- Wear your safety goggles and blue gloves.
- Make sure the balance pan is clean and dry.
- A clean plastic weigh dish rests on the digital balance.
Careful: If you spill chemical powder on the balance pan, readings become incorrect. Scoop small amounts slowly. Brush away any loose crystals on the bench.

Step 2 of 6
Assemble the cup calorimeter
- Carefully drop the magnetic stir bar into the cup.
- Measure exactly 50.0 mL of room-temperature water in the graduated cylinder.
- Pour all 50.0 mL of water into the foam cup.
- Check the bottom of the graduated cylinder at eye level for the meniscus.
- The foam cup sits flat inside the glass beaker.
- The foam cup is placed inside the 400 mL glass beaker for support.
Careful: If you drop the magnetic stir bar heavily, it can puncture the foam cup. Tilt the cup slightly and slide the stir bar down the side gently.

Step 3 of 6
Position the probe on the Stir Station
- Place the beaker setup onto the centre of the Stir Station platform.
- Clamp the Go Direct Temperature Probe handle upright.
- Lower the probe so the metal tip is deep in the water, above the stir bar.
- The clamp thumbscrew is tightened securely on the rod.
- The probe tip does not touch the stir bar or the bottom of the cup.
- The Electrode Support clamp is slid onto the metal stand rod.
Careful: If the probe touches the stir bar, it will rattle, scratch, and give noisy readings. Keep the probe tip at least 1 cm above the cup floor and slightly off-centre.

Step 4 of 6
Establish a steady baseline temperature
- Turn on the Stir Station knob to a gentle, steady speed (setting 3 or 4).
- Watch the live temperature meter on your tablet for about 45 seconds.
- Wait until the temperature stops change and holds steady at room temperature.
- The stir bar spins smoothly and does not splash liquid.
- The temperature probe is held firmly in place.
- Do not add any solid yet.
Careful: If you stir too fast, the stir bar can wobble or splash water out. Keep the speed dial low (around setting 3) so the liquid swirls gently.

Step 5 of 6
Start collecting and add the urea
- Tap the green Collect button on your tablet.
- Let data collect for exactly 10 seconds to establish your baseline.
- At 10 seconds, smoothly tip all 10.0 g of urea into the cup.
- The weigh dish of urea is ready in your hand.
- One partner watches the tablet timer.
- Continue to stir gently as the temperature line plunges downward.
Careful: If you add the solid too fast, it can clump around the stir bar. Pour smoothly into the liquid vortex. Do not hit the probe shaft.
1 more step, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 11, Chemistry, chapter 4: Chemical Bonding and Molecular Structure
- Direct Level AS & A Level, Chemistry, chapter 6: Enthalpy changes
- Direct Level AS & A Level, Chemistry, chapter 19: Lattice energy
- Direct Level AS & A Level, Chemistry, chapter 23: Entropy and Gibbs free energy
Versions and what each needs
- How do cold packs work?
Chemistry through Inquiry, 45 min, Based on a Vernier lab
Needs: Go Direct Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.