Experiments › Environmental Science

How do fish breathe underwater?

Dissolved Oxygen in Water

Grades 7-8Environmental Science4 versions

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 5 steps. To run it with the sensors, record data and take the quiz, students use the app.

A freshwater fish swimming near aquatic green plants underwater

Wonder

How do fish breathe if water is not air?

Show the answer

Water holds invisible dissolved oxygen gas between its molecules. Today you will measure this hidden oxygen with an optical probe.

Rushing stream tumbling over stones and churning white foam

Introduction

The Invisible Breath of the River

When you jump into a lake, you cannot breathe underwater without scuba gear. Yet fish, insects, and crabs thrive there for their entire lives! Where do they get oxygen? Tiny oxygen molecules from the air and water plants slip between liquid water particles. This is called dissolved oxygen. Today, you will use an optical sensor to measure exactly how much oxygen is floating inside a water sample.

Driving question: How much invisible oxygen is dissolved in water for fish to breathe?

What you will learn

Goals for this investigation

  • I can use an optical sensor to measure dissolved oxygen in water.
  • I can explain where dissolved oxygen comes from and why aquatic life needs it.
  • I can identify factors that change how much oxygen dissolves in water.
  • I can interpret a dissolved oxygen graph to evaluate water health.

Why it matters: Fish and aquatic ecosystems can suffocate when oxygen drops. Environmental scientists measure dissolved oxygen to keep lakes healthy.

Safety first

Laboratory Safety Rules

  • Wear safety goggles and lab gloves throughout the investigation.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Keep electronic sensors and tablets at least 30 cm away from open water beakers.
  • Never drink any water sample tested in the laboratory.
  • The optical probe tip contains a delicate sensor window. Never scratch or scrape it.
  • Report any spills immediately to your teacher. Dry your hands before you touch cables.

What you need

  • Go Direct Optical Dissolved Oxygen Probe1
  • Go Direct Temperature Probe1
  • 250 mL beaker1
  • Distilled water wash bottle1
  • Tablet running Graphical Analysis1
  • Lint-free tissue box1 box
Student hand pressing the power button on the optical dissolved oxygen probe

Step 1 of 5

Power on and pair your sensors

  1. Press the power button once on the Go Direct Optical DO Probe, then press the Go Direct Temperature Probe.
  2. Open Graphical Analysis on your tablet. Tap Sensor Data Collection.
  3. Connect both probes with Bluetooth.
Stop and check
  • Your hands and the lab bench are dry.
  • Tablets are placed at least 30 cm away from water.
  • Confirm the readings appear on the screen.

Careful: Moisture on electronic ports can cause short circuits or connection errors. Keep electronics away from open water beakers.

Student gently removing the storage cap from the optical DO probe

Step 2 of 5

Remove storage cap and rinse probe tip

  1. Gently twist and slide the grey protective storage cap off the probe tip.
  2. Use a wash bottle to rinse the probe tip with distilled water over a sink or waste cup.
  3. Gently dab the outer plastic dry with a tissue. Do not rub the flat tip.
Stop and check
  • Work over a tray or sink when you rinse.
  • Keep the wet sponge inside the storage cap safe for later.
  • Examine the black tip.
  • Never touch the delicate optical cap with bare fingers.

Careful: If you scratch the optical window with rough paper, you permanently ruin the sensor. Only dab the probe gently with a lint-free tissue; never wipe or scrub the tip.

Student holding optical DO probe and temperature probe in a beaker of water

Step 3 of 5

Submerge probes in your water sample

  1. Place the 250 mL beaker of water firmly on the flat bench top.
  2. Submerge the tip of the Optical DO Probe 4 to 6 cm into the water sample.
  3. Submerge the stainless-steel Temperature Probe into the same beaker.
Stop and check
  • The beaker sits flat on the table, not near an edge.
  • The probe tip is submerged at least 4 cm under water.
  • Hold both probes steady. Do not touch the glass walls or bottom of the beaker.

Careful: If you knock the beaker over, water spills across the table. Keep the beaker in the centre of the table. Hold the probes gently.

Tablet plotting live dissolved oxygen data next to the submerged probe

Step 4 of 5

Collect dissolved oxygen data

  1. Hold both probes steady in the beaker, or work with a partner. Tap Collect on the tablet with your free hand.
  2. Watch the live graph as the reading levels out.
  3. Wait the full 60 seconds until data collection stops automatically.
Stop and check
  • Probes remain still in the water sample.
  • One teammate monitors the tablet graph.
  • Hold the optical probe still.

Careful: If you move the probe violently, water splashes and air bubbles enter. Keep the probe completely still while the optical sensor measures.

Statistics box displayed over a flat graph line showing a mean of 8.13 mg per litre

Step 5 of 5

Find average dissolved oxygen value

  1. Drag across the flat, stable part of your graph from 20 s to 60 s.
  2. Tap Graph Tools. Select View Statistics.
  3. Write down the Mean DO (in mg/L) and the water temperature (in °C).
Stop and check
  • The graph line is stable and horizontal.
  • You have highlighted the flat section.
  • Read the Mean value displayed in the statistics box.

Careful: If you select the initial curved region, you skew the calculated average. Only select the flat, stable region after 20 seconds.

0 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Direct Class 8, Science, chapter 6: Reproduction in Animals
  • Direct Class 8, Science, chapter 9: The Amazing World of Solutes, Solvents, and Solutions
  • Direct Class 12, Chemistry, chapter 1: Solutions
ICSE (CISCE)
  • Direct Class 8, Chemistry, chapter 11: Dissolution of Salts in Water
  • Related Class 9, Chemistry, chapter 3: Water
Cambridge AS & A Level
  • Direct Level AS & A Level, Biology, chapter 18: Classification, biodiversity and conservation
IB Diploma
  • Direct Level DP, Biology, chapter A1.1: Water

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.