Experiments › Chemistry
How do hand warmers work?
Hand Warmers
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
How can dry white powder warm your freezing winter mittens?
Show the answer
Squeezing a pouch snaps a water packet inside. When the water dissolves the powder, chemical bonds shift and release instant warmth. Today you test which powder makes the best pocket heater!

Introduction
The Pocket Heater Puzzle
On freezing winter mornings, slipping a tiny heat pouch into your gloves keeps your fingers toasty for hours. There are no batteries, wires, or flames inside. Instead, clicking or squeezing the packet mixes dry mineral crystals with water. As the crystals dissolve, they release instant heat! In this lab, you become a product designer: measure how different dissolving powders change water temperature, track the heat graphs live, and decide which powder makes the ultimate hand warmer.
Driving question: Which everyday powder makes the hottest, safest, and most affordable hand warmer?
What you will learn
Your Mission Today
- I can tell whether dissolving a solid makes water hotter or colder.
- I can measure and record temperature changes as solids dissolve in water.
- I can calculate how much the temperature changed for each powder.
- I can use a foam cup calorimeter correctly to prevent heat loss.
- I can choose the best chemical for a real hand warmer using test data and price.
Why it matters: Emergency paramedics use instant heat and cold packs to treat hypothermia and sprained ankles in seconds without electricity.
Safety first
Laboratory Safety Rules
- Wear safety goggles and light blue protective gloves throughout the lab.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Never taste or touch any chemical powders with bare skin. Lab salts are non-food grade.
- Calcium chloride and sodium carbonate can irritate eyes and skin. Wash hands immediately if touched.
- Keep water containers at least 30 cm away from tablets and charging ports.
- Gently stir with the probe: do not stab or poke the bottom of the foam cup.
- Dispose of all dissolved chemical mixtures down the sink with plenty of tap water that runs.
What you need
- Go Direct Temperature Probe1
- Tablet running Graphical Analysis1
- foam coffee cups2
- 400 mL beaker1
- 50 mL graduated cylinder1
- balance, ±0.01 g accuracy1 per station
- weigh boats4
- distilled water250 mL
- magnesium sulfate, anhydrous15 g
- calcium chloride, anhydrous15 g
- ammonium chloride, anhydrous15 g
- safety goggles1 per student

Step 1 of 8
Assemble your cup calorimeter
- Take one foam coffee cup and nest it inside a second foam cup for extra insulation.
- Place the nested foam cups inside the 400 mL glass beaker.
- The glass beaker acts as a heavy base so your lightweight foam cup cannot tip over.
- The foam cups are dry and free from cracks.
- The 400 mL beaker is clean and sits flat on the table.
Careful: Foam cups are very light and can easily tip over when liquids are stirred. Always keep the foam cups seated firmly inside the glass beaker.

Step 2 of 8
Measure and add distilled water
- Use the 50 mL graduated cylinder to measure exactly 50.0 mL of room-temperature distilled water.
- Look at eye level: the bottom of the curved water surface (meniscus) must touch the 50.0 mL line.
- Carefully pour all 50.0 mL into your nested foam cup.
- Graduated cylinder is clean.
- Pour slowly to avoid water splashes on the table.
Careful: If you measure too much or too little water, the temperature result changes. Read the water line at eye level and pour carefully.

Step 3 of 8
Weigh the magnesium sulfate
- Place a clean plastic weigh boat on the digital balance and press the Zero (Tare) button.
- Use a clean spatula to add anhydrous magnesium sulfate until the balance reads about 5.00 g.
- Record the exact mass in your data table (for example, 5.04 g).
- Balance reads 0.00 g with the empty boat on it.
- Wear gloves and keep the spatula dry.
- The screen should read 0.00 g.
Careful: Spilt powder on the balance pan ruins the measurement and creates a mess. Add small scoops of powder slowly into the center of the weigh boat.

Step 4 of 8
Connect and insert the temperature probe
- Press the power button on the Go Direct Temperature Probe.
- Open Graphical Analysis on your tablet. Connect to the probe with Bluetooth.
- Lower the metal tip into the water inside the foam cup.
- Bluetooth is enabled on your tablet.
- Probe light blinks green once connected.
- The light will flash red.
- Keep the probe tip in the water. Do not let it touch the bottom or sides of the cup.
Careful: If the probe tip touches the foam cup wall, it measures the cup temperature rather than the water. Keep the probe tip suspended centrally in the middle of the water.

Step 5 of 8
Record baseline and add the salt
- Tap the green 'Collect' button in Graphical Analysis.
- At exactly 10 seconds, dump ALL the magnesium sulfate powder into the cup at once.
- Immediately start to stir the water. Use the probe to make gentle circles.
- Probe is in the water.
- Powder is ready in the weigh boat.
- The timer on the tablet runs.
- Watch the graph for 10 seconds: the line should stay flat.
Careful: If you dump the powder before you start data collection, you ruin the baseline start temperature. Wait for 10 seconds of steady readings before you pour in the powder.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Level AS & A Level, Chemistry, chapter 11: Group 2
- Direct Level AS & A Level, Chemistry, chapter 19: Lattice energy
- Related Level AS & A Level, Chemistry, chapter P2: Practical skills 2
Versions and what each needs
- How do hand warmers work?
AP Chemistry, 60 min, Based on a Vernier lab
Needs: Go Direct Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.