Experiments › Physical Science
How do heat and squeezing change gas pressure?
Gas Laws
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does a bicycle pump get harder to push as you squeeze down?
Show the answer
Trapped air particles push back harder when squeezed into a smaller space. Today you will measure this invisible push with a digital sensor.

Introduction
The Secret Push of Trapped Air
Air is all around us, but we cannot see it. Even though air seems empty, it is made of trillions of tiny moving particles. When these particles bump into walls, they push. We call this push gas pressure. What happens when you trap air inside a syringe and squeeze it down? Today, you will use a Go Direct Gas Pressure Sensor to discover how squeezing air changes its push.
Driving question: What happens to the invisible push of trapped air when you squeeze it?
What you will learn
Today you will find out
- I can explain what gas pressure really is.
- I can record how squeezing a syringe changes gas pressure.
- I can explain why smaller volume creates higher gas pressure.
- I can connect gas tubing and sensors to make an airtight seal.
- I can explain why bike tyres feel harder in hot weather.
Why it matters: Understanding gas pressure helps engineers design space suits, car tyres, scuba gear, and weather balloons.
Safety first
Scientist Rules for Gas Experiments
- Wear eye protection. Air under pressure can pop stoppers or tubes off quickly.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Never force the syringe plunger below 5 mL. High pressure can damage the sensor diaphragm.
- Warm water must stay below 50°C. An adult prepares and pours warm water.
- Keep all water containers at least 30 cm away from tablets and sensor ports.
- Wash your hands with soap and water after cleanup.
What you need
- Go Direct Gas Pressure Sensor1 per group
- Go Direct Temperature Probe1 per group
- plastic syringe1 (20 mL with Luer-lock tip)
- 125 mL Erlenmeyer flask1 per group
- flexible plastic tubing1 with two-hole stopper and valve
- 600 mL beaker1 for water bath
- Tablet running Graphical Analysis1 per group
- safety goggles1 per student

Step 1 of 7
Trap air in the syringe at 10 mL
- Put on your safety goggles.
- Pull the syringe plunger back until the front edge of the black ring sits right at 10.0 mL.
- Do not attach the sensor yet. We want room air trapped at normal pressure first.
- Everyone has safety goggles on.
- Syringe barrel is completely clean and dry.
- The sensor port is open to room air.
Careful: If you pull the plunger completely out, pieces can drop on the floor. Pull gently and stop at the 10 mL line.

Step 2 of 7
Attach the syringe to the sensor
- Hold the Go Direct Gas Pressure Sensor flat on the table.
- Push the syringe tip straight into the green valve on the sensor.
- Give the syringe a gentle half-turn clockwise to lock it securely.
- Do not over-twist! A gentle half-turn creates a perfect airtight seal.
- The plunger still rests at 10 mL.
- The green sensor port is clean and free of dust.
Careful: If you twist too hard, you can strip or crack the plastic Luer-lock threads. Turn only half a turn until snug. Never force it.

Step 3 of 7
Record your starting point at 10 mL
- Tap Collect in Graphical Analysis.
- Hold the plunger at 10.0 mL. Check the pressure number on the tablet.
- When the reading stays steady, tap Keep.
- Type 10.8 (10.0 mL on the syringe plus 0.8 mL trapped inside the sensor). Tap Keep Point.
- The sensor shows a steady reading around 100 kPa.
- The plunger stays firmly at 10.0 mL and does not slip.
Careful: If you tap Keep before the number settles, you get noisy data points. Wait 3 seconds for the number to settle. Then tap Keep.

Step 4 of 7
Compress the air down step by step
- Carefully push the plunger down to 8.0 mL. Hold it firmly so it cannot push back!
- When the reading steadies, tap Keep and enter 8.8 mL.
- Push down to 6.0 mL. Hold it tight. Tap Keep. Enter 6.8 mL.
- Notice how hard the air pushes back against your thumb as the volume shrinks!
- Do NOT push below 5.0 mL.
- Hold the plunger with a firm grip so it does not snap back.
Careful: The compressed air pushes back strongly. If your thumb slips, the plunger can snap out suddenly. Keep a steady, two-handed grip on the syringe body and plunger.

Step 5 of 7
Expand the air outward step by step
- Pull the plunger out to 12.0 mL. Hold it steady. Tap Keep. Enter 12.8 mL.
- Pull out to 14.0 mL. Hold steady. Tap Keep. Enter 14.8 mL.
- Pull out to 16.0 mL and then 18.0 mL. Record each point with the extra 0.8 mL added.
- When finished, tap Stop to end data collection.
- Plunger stays inside the syringe barrel.
- The sensor stays flat on the table.
Careful: If you pull past 20 mL, the plunger can come completely out of the syringe. Stop before you reach the 20 mL line.
2 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 11, Physics, chapter 5: Kinetic Theory
- Related Level AS & A Level, Chemistry, chapter 5: States of matter
- Direct Level AS & A Level, Physics, chapter 15: Ideal gases
- Direct Level DP, Chemistry, chapter Structure 1.5: Ideal gases
Versions and what each needs
- How do heat and squeezing change gas pressure?
Advanced Chemistry, 60 min, Based on a Vernier lab
Needs: Go Direct Gas Pressure Sensor, Go Direct Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.