Experiments › Environmental Science

How do lakes fight acid rain?

Alkalinity

Grades 7-8Environmental Science1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

Two mountain lakes under rain clouds, one healthy with swimming fish and one lifeless

Wonder

Why does acid rain destroy fish in one lake, but leave a nearby lake unharmed?

Show the answer

Some lakes have a hidden shield called alkalinity. Minerals in the water soak up acid before it hurts living things. Today, you will measure this chemical shield.

Diagram of acid rain falling on a lake with limestone rocks at the bottom

Introduction

The Lake's Secret Shield

When acid rain falls into a lake, you might expect the water to turn sour right away. But many lakes resist! Rocks like limestone dissolve slowly into water, releasing carbonate particles. These particles act like tiny sponges that soak up acid. This protective superpower is called alkalinity. Today, you will add acid drop by drop to find out how strong your water sample's shield really is.

Driving question: Why can some lakes survive acid rain while other lakes turn dangerously sour?

What you will learn

Today you will find out

  • I can explain how alkalinity shields water from acid.
  • I can set up a titration station safely.
  • I can find the turning point on a titration graph.
  • I can calculate alkalinity from my titration data.
  • I can explain why high-alkalinity lakes protect fish from acid rain.

Why it matters: Environmental scientists test alkalinity to predict which lakes will die from acid rain and how drinking water plants must treat tap water.

Safety first

Lab Rules for Testing Water

  • Wear chemical splash goggles and protective gloves throughout this lab.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Dilute sulfuric acid is corrosive. An adult handles the acid bottle and fills the reservoir.
  • If acid spills on skin or clothes, rinse immediately with plenty of tap water.
  • Keep all water and acid containers at least 30 cm away from tablets and charging ports.
  • Handle glass beakers and the glass bulb of the pH sensor with care.
  • Never taste or drink water samples from lakes or lab beakers.

What you need

  • Go Direct pH Sensor1
  • Go Direct Drop Counter1
  • Reagent Reservoir, 2 Valves, and Tip1 · teacher
  • Microstirrer1
  • 0.0100 M H2SO4 solution70 mL
  • sample container150 mL
  • 250 mL beakers2
  • 100 mL graduated cylinder1
  • ring stand1
  • magnetic stirrer1
  • wash bottle1
  • goggles1 per student
Student pouring water into a graduated cylinder at eye level

Step 1 of 7

Measure 100 mL of sample water

  1. Put on your safety goggles and light blue lab gloves.
  2. Pour your water sample into the 100 mL graduated cylinder.
  3. Check eye level: the bottom of the water curve must sit right on the 100.0 mL line.
  4. Carefully pour all 100.0 mL into a clean 250 mL beaker.
Stop and check
  • Goggles and gloves are on.
  • The graduated cylinder rests flat on the table.
  • Table surface is clean and dry.

Careful: Water splashes on electronic sensors, or you read volume lines incorrectly. Pour smoothly and read volume at eye level from the bottom curve (meniscus).

Beaker sitting centered on a magnetic stirrer on the base of a ring stand

Step 2 of 7

Set up the beaker and magnetic stirrer

  1. Place the 250 mL beaker with your water sample onto the magnetic stirrer.
  2. Position the stir plate directly onto the heavy metal base of the ring stand.
  3. Keep the stirrer powered off for now while we assemble the clamps above it.
Stop and check
  • Stirrer power cord is placed away from walkways.
  • The beaker sits squarely in the middle of the stir plate.

Careful: The beaker tips if you place it off-center on the stir plate. Center the beaker. Make sure that the stand is steady.

Go Direct pH Sensor inserted through the Drop Counter into the beaker

Step 3 of 7

Attach the Drop Counter and pH Sensor

  1. Clamp the Go Direct Drop Counter to the ring stand rod above the beaker.
  2. Unscrew the storage bottle from the pH Sensor, rinse bulb with distilled water, and slide Microstirrer paddle onto glass tip.
  3. Slide the pH Sensor through the Drop Counter large hole into the water. Turn the stirrer to low speed so liquid does not splash.
Stop and check
  • Sensor storage bottle is placed upright in a safe spot.
  • Sensor glass bulb is completely submerged in water.
  • The microstirrer paddle can spin freely and does not touch glass walls.

Careful: The delicate glass bulb of the pH sensor can break if struck against the beaker. Tighten the clamps gently. Make sure that the tip hangs 5 mm above the beaker bottom.

Teacher pouring sulfuric acid into the reagent reservoir clamped to ring stand

Step 4 of 7 Teacher does this

Fill the reagent reservoir with acid

  1. Close both red valves on the reagent reservoir horizontally. Clamp the reservoir to the ring stand above the Drop Counter slot.
  2. Slide the sample beaker away and place a waste beaker under the reservoir tip.
  3. Carefully pour about 60 mL of 0.0100 M H2SO4 acid solution into top, open both valves briefly to fill tip, then close both.
Stop and check
  • The teacher wears purple gloves and splash goggles.
  • A waste beaker sits under the tip when you prime the valves.
  • Students keep hands back when someone pours acid.

Careful: Sulfuric acid splashes on skin, clothes, or the tabletop. Only the adult handles the acid bottle and fills the reservoir. Wipe any external drips immediately.

Close-up of drop alignment through the Go Direct Drop Counter window

Step 5 of 7

Adjust drop rate and align the tip

  1. Swing the sample beaker back under the Drop Counter so the tip points straight into it.
  2. Line up the reservoir tip directly over the rectangular window of the Drop Counter.
  3. Keep the bottom valve closed (shutoff valve).
  4. Adjust the top valve (rate valve) so drops fall at a steady pace: 1 drop every 2 seconds.
  5. Close the bottom valve after you set the rate.
Stop and check
  • Every drop falls through the center of the Drop Counter slot.
  • Drops fall into the stirred beaker and do not splash.
  • Tablet is connected and ready.

Careful: Drops hit the sensor frame instead of the drop slot. This causes uncounted acid. Look directly from above and front. Make sure that the drop falls cleanly through the slot.

2 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

Cambridge AS & A Level
  • Related Level AS & A Level, Chemistry, chapter 21: Further aspects of equilibria
IB Diploma
  • Related Level DP, Environmental Systems and Societies, chapter 4: Water and aquatic food production systems and societies

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.