Experiments › Chemistry

How do liquids defend their pH?

Buffer Effectiveness

Grades 7-8Chemistry2 versions

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

A glass of sour lemonade beside a medical diagram showing healthy human blood cells

Wonder

Why does your blood stay perfectly balanced even after a glass of sour lemon juice?

Show the answer

Your body uses a chemical shield called a buffer. It swallows extra acids and bases so your pH stays safely between 7.2 and 7.6. Today you will build and test this liquid shield.

A tall glass of fresh white milk sitting beside a freshly sliced yellow lemon on a plain table

Introduction

The Liquid Shield

Add a few drops of acid to plain water, and its pH plunges instantly. But add that same acid to your bloodstream or milk, and the pH barely moves! How do these liquids fight back? They contain invisible chemical partners that catch incoming acids and bases. In this investigation, you will use a Go Direct pH Sensor to test how much attack a buffer liquid can take before its shield breaks.

Driving question: How can a liquid shield itself so its pH barely moves when attacked by strong acids or bases?

What you will learn

Today you will find out

  • I can explain how a buffer shields a liquid from big pH changes.
  • I can observe the slow, flat pH change while a buffer shield is working.
  • I can show why a stronger buffer holds out longer before breaking.
  • I can safely set up the pH sensor and Stir Station with my teacher.
  • I can name where buffers protect life in the human body and nature.

Why it matters: Without natural buffers, swimming in a lake, digesting food, or drinking juice would be life-threatening.

Safety first

Lab Rules for Testing Corrosive Chemicals

  • Wear splash goggles, protective gloves, and a lab apron at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Hydrochloric acid (HCl) and sodium hydroxide (NaOH) can cause skin burns and eye damage.
  • The teacher fills all burets and handles the concentrated stock bottles.
  • Keep the tablet and electronics at least 30 cm back from the stir station.
  • If any liquid touches skin, rinse immediately with cold tap water for 15 minutes and tell the teacher.
  • Wash your hands fully with soap at the end of class.

What you need

  • Go Direct pH Sensor1
  • Stir Station1
  • Electrode Support1
  • 50 mL burets and buret clamp2 burets, 1 clamp · teacher
  • Tablet running Graphical Analysis1
  • 250 mL beakers4
  • 25 mL graduated cylinder1
  • magnetic stir bar1
  • Buffer A (0.1 M) and Buffer B (1.0 M) solutions50 mL each
  • 0.50 M NaOH and 0.50 M HCl solutions60 mL each · teacher
  • Distilled water wash bottle1
  • Splash goggles and nitrile gloves1 pair per student
Teacher in purple gloves carefully pouring clear solution into the top of a glass buret

Step 1 of 7 Teacher does this

Adult fills and checks the burets

  1. The teacher mounts two 50 mL burets side by side on the ring stand.
  2. With a small glass funnel, the teacher fills one buret with 0.50 M NaOH and the second with 0.50 M HCl.
  3. Check that each buret tip is full of liquid and free of trapped air bubbles.
Stop and check
  • The teacher wears purple gloves, a lab coat, and splash goggles.
  • Buret clamp holds both burets firmly upright.
  • A waste beaker sits under the tips while the teacher fills the burets.

Careful: Corrosive 0.5 M acid or base can splash onto skin, eyes, or clothes when you pour. Only the teacher pours solutions into the burets. Keep waste beaker underneath.

Student mounting the Go Direct pH Sensor into the black electrode support clamp on the rod

Step 2 of 7

Set up the Stir Station and sensor

  1. Place the Stir Station on the lab bench directly under the burets.
  2. Attach the electrode support clamp to the vertical rod.
  3. Unscrew the storage bottle from the pH sensor, rinse the glass bulb with distilled water, and clamp it securely.
  4. Position the sensor tip so it will be deep in liquid, but well clear of the beaker floor.
Stop and check
  • Stir Station power cord is routed safely away from water.
  • The delicate glass bulb of the pH sensor is kept wet.

Careful: The thin glass pH bulb can shatter if clamped too tight or bumped against metal. Handle the pH sensor gently by its plastic shaft and tighten clamps by hand only.

Student pouring 20 mL of clear buffer solution into a 250 mL beaker

Step 3 of 7

Measure 20 mL of Buffer A

  1. Use the 25 mL graduated cylinder to measure exactly 20 mL of Buffer A (0.1 M).
  2. Pour the buffer into a clean 250 mL beaker.
  3. Tilt the beaker so it does not splash. Gently slide in a small magnetic stir bar.
  4. Place the beaker onto the centre of the Stir Station platform.
Stop and check
  • Goggles and blue gloves on.
  • Beaker is clean and completely dry outside.

Careful: If you drop a stir bar forcefully into glass, you can crack the beaker bottom. Tilt the beaker and let the stir bar slide down the side gently.

Student's gloved hand adjusting buret valve while drops fall into beaker on Stir Station

Step 4 of 7

Record starting pH and begin dripping base

  1. Lower the pH sensor into the beaker. Position the NaOH buret tip right over the top.
  2. Turn on the Stir Station to setting 3. Make sure that the stir bar does not touch the sensor bulb.
  3. Tap Collect on the tablet. Before you add any base, tap Keep. Type 0.0 mL.
  4. Carefully open the buret stopcock to add about 0.5 mL of 0.50 M NaOH.
  5. Wait 5 seconds for the reading to stabilize. Tap Keep. Type the exact buret volume.
Stop and check
  • The stir bar spins smoothly in the centre without clatter.
  • Sensor bulb is submerged at least 2 cm into liquid.
  • Buret tip is positioned inside the beaker rim to avoid drips on the bench.

Careful: The stopcock valve can open too quickly and release liquid all at once. Pinch the stopcock with two fingers. Rotate it slowly. Watch drops one by one.

Tablet screen showing an S-shaped titration curve with a steep rise around 2.7 mL

Step 5 of 7

Watch for the shield to break

  1. Continue to add 0.50 M NaOH in small 0.3 to 0.5 mL increments.
  2. Record each point. Notice how slowly the pH climbs at first: from 4.0 to about 5.5.
  3. Around 2.5 to 3.0 mL, watch the screen: the pH suddenly shoots up past 10!
  4. Add 2 more increments to complete the S-curve. Then tap Stop.
Stop and check
  • Stir speed remains moderate and the liquid does not splash.
  • Goggles stay firmly over eyes.

Careful: Too much liquid in the beaker can cause chemical overflow onto the Stir Station. Do not add more base once the pH reaches 12 and the curve levels off.

2 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

Cambridge AS & A Level
  • Direct Level AS & A Level, Chemistry, chapter 21: Further aspects of equilibria

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.