Experiments › Agricultural Science

How do living things tame acids?

Acids and Bases

Grades 7-8Agricultural Science2 versions

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 5 steps. To run it with the sensors, record data and take the quiz, students use the app.

A fresh sliced potato and lemon on a rustic wooden table with splashes of liquid

Wonder

How do living creatures survive acid rain, sour foods, and harsh soil?

Show the answer

Living things have invisible shields called buffers that soak up acid and base. Today you will measure how they protect living cells from sudden pH shocks.

Rain falling onto green potato plant leaves in a garden

Introduction

Why Doesn't Acid Change Everything?

When acid rain falls into a puddle, the water becomes sour and acidic almost instantly. But inside a plant stem or your own bloodstream, the chemical balance stays remarkably calm! How do living organisms defend themselves against rapid chemical shocks? Living tissues contain natural guards called buffers. Today, you will drop real acid and base into water and potato juice to watch these chemical shields in action.

Driving question: Why does adding acid make tap water's pH crash, while potato juice hardly changes at all?

What you will learn

Today you will discover

  • I can record pH changes when acid or base is added drop by drop.
  • I can explain how a buffer protects a liquid from drastic pH changes.
  • I can rank substances from weakest buffer to strongest buffer.
  • I can rinse and handle a flat pH sensor and test solutions safely.
  • I can describe why buffers matter in soil, farm crops, and human bodies.

Why it matters: Farmers test soil buffering so crops don't wither from acid rain. Doctors rely on blood buffers to keep patients alive every second.

Safety first

Laboratory Safety Rules

  • Wear chemical splash goggles and an apron at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Hydrochloric acid (0.1 M HCl) and sodium hydroxide (0.1 M NaOH) can irritate eyes and skin.
  • If any drop touches your skin, rinse immediately with lots of cold water.
  • The pH sensor has a fragile glass tip. Never tap or hit it against the bottom of glass beakers.
  • Keep the sensor in tap water when you do not do a test.

What you need

  • Go Direct Flat pH Sensor1 per group
  • 250 mL beaker1 per group
  • 50 mL beakers2 per group
  • 50 mL graduated cylinder1 per group
  • Distilled water wash bottle1 per group
  • 0.1 M Hydrochloric acid solution10 mL in dropper bottle
  • 0.10 M Sodium hydroxide solution10 mL in dropper bottle
  • Biological test solution (potato extract)50 mL per group
  • Splash goggles and nitrile gloves1 set per student
Student rinsing the tip of the pH sensor with a wash bottle into a waste beaker

Step 1 of 5

Prepare the pH Sensor Storage

  1. Remove the storage bottle from the Go Direct Flat pH Sensor.
  2. Rinse the glass tip with distilled water from your wash bottle over a waste sink or basin.
  3. Pour about 100 mL of tap water into the 250 mL beaker. Stand the sensor upright so the tip stays wet.
Stop and check
  • Goggles and lab apron are on.
  • 250 mL beaker contains about 100 mL tap water.
  • Table surface is dry and clear.
  • Pour about 100 mL of tap water into the 250 mL beaker.

Careful: The delicate glass electrode can dry out or break if dropped against hard surfaces. Always keep the probe in water. Handle the probe with care.

pH sensor resting in a 50 mL beaker of water labeled Acidic

Step 2 of 5

Measure Initial pH of Water

  1. Label a 50 mL beaker 'Acidic'. Use your graduated cylinder to add 20 mL of distilled water.
  2. Rinse the pH sensor with distilled water, then lower it into the water.
  3. Tap Collect in Graphical Analysis. When the reading settles, tap Keep. Type 0 for Drops. Tap Keep Point.
Stop and check
  • Beaker is clearly labeled 'Acidic'.
  • Exactly 20 mL of distilled water measured at eye level.
  • The sensor tip rests gently in the liquid and does not touch the glass bottom.
  • Label one 50 mL beaker 'Acidic'.
  • Measure exactly 20 mL of distilled water with the graduated cylinder. Pour it into this beaker.

Careful: If you tap the glass sensor against the hard beaker, you can crack the fragile electrode. Lower the sensor gently and hold it steady by the black handle.

Student adding drops of acid from a plastic pipet into the beaker

Step 3 of 5

Add Acid to Water Drop by Drop

  1. Add 5 drops of 0.1 M HCl acid to the beaker.
  2. When the reading is steady, tap Keep, type 5 for Drops, and tap Keep Point.
  3. Add 5 drops at a time up to 30 drops. Record data at 10, 15, 20, 25, and 30 drops. Tap Stop.
Stop and check
  • You wear goggles and an apron.
  • Check dropper bottle label: 0.10 M HCl (Acid).
  • Hold dropper vertically so drops are equal size.
  • Swirl the beaker gently for 5 seconds to mix fully after you add drops.

Careful: 0.1 M HCl can irritate skin and cause eye damage if splashed. Squeeze dropper gently right above the liquid. Rinse any splashes with water immediately.

Student testing basic water in 50 mL beaker labeled Basic

Step 4 of 5

Test the Effect of Base on Water

  1. Label a second 50 mL beaker 'Basic'. Add 20 mL of fresh distilled water.
  2. Place the sensor in the beaker. Tap Collect. Record the initial 0-drop pH.
  3. Now add 0.1 M NaOH (base) 5 drops at a time, swirling and recording up to 30 drops; tap Stop at 30 drops.
Stop and check
  • Check dropper bottle label: 0.10 M NaOH (Base).
  • Do NOT mix acid and base droppers.
  • Rinse the sensor fully before it enters basic water.
  • Rinse the pH sensor fully with distilled water. Return it to the 250 mL storage beaker.
  • Label the second 50 mL beaker 'Basic' and pour in 20 mL of fresh distilled water.

Careful: Sodium hydroxide is caustic and causes skin and eye irritation. Wear goggles and gloves. Rinse any skin contact with water for several minutes.

Testing potato extract with pH sensor and dropper

Step 5 of 5

Test the Biological Sample (Potato Extract)

  1. Rinse both 50 mL beakers. Add 20 mL of potato extract into each beaker.
  2. Test the 'Acidic' beaker with 0.1 M HCl acid up to 30 drops. Add 5 drops at a time. Record every step.
  3. Rinse sensor with distilled water; test 'Basic' beaker with 0.1 M NaOH base up to 30 drops (5 drops at a time) and record.
Stop and check
  • Potato extract is mixed and non-oily.
  • Beakers are rinsed clean of leftover acid and base.
  • Sensor rinsed with distilled water between tests.
  • Rinse both 50 mL beakers fully with water.
  • Pour 20 mL of potato extract into the 'Acidic' beaker and 20 mL of potato extract into the 'Basic' beaker.

Careful: If you cross-contaminate potato solution with leftover chemicals, you get false buffer curves. Rinse beakers and probe tip with distilled water between runs.

0 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 10, Science, chapter 2: Acids, Bases and Salts
  • Related Class 11, Chemistry, chapter 6: Equilibrium

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.