Experiments › Chemistry
How do molecules swap parts?
Synthesis of 1-Bromobutane and Gas Chromatography Analysis
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can molecules swap parts like building blocks to form an entirely new substance?
Show the answer
When two chemicals collide, atoms can knock other atoms loose and take their spots. Today you will witness this swap and race the molecules to identify the new product.

Introduction
The Molecular Trade
Imagine playing soccer and swapping one player on the field for a fresh striker. Molecules do the exact same thing! In a substitution reaction, one atom knocks out an existing group and takes its spot on a carbon chain. But because molecules are invisible, how do scientists prove the swap actually happened? Today we use a miniature gas race machine and a colour-changing chemical test to catch the newly formed substance.
Driving question: Can we watch molecules trade atoms and prove what new substance formed?
What you will learn
Today you will discover
- I can explain how molecules trade atoms to make a new substance.
- I can read gas chromatography peaks to tell different chemicals apart.
- I can use a chemical test to prove a new substance was made.
- I can follow strict safety rules when observing heated chemicals.
- I can explain how forensic labs and drug makers identify pure compounds.
Why it matters: Pharmaceutical factories, perfume makers, and crime investigators rely on molecular swaps and chromatography to make and identify pure materials every single day.
Safety first
Essential Lab Safety Rules
- Wear splash goggles, chemical-resistant gloves, and a fastened lab coat at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Part I uses concentrated sulfuric acid and heated sand. Only the teacher handles these materials in a fume hood.
- 1-Butanol and acetone are flammable liquids. Keep bottles away from open heat and sparks.
- Micro-syringe needles are sharp and fragile. Handle them only when instructed. Point the needle downward.
- Never smell, taste, or touch chemical liquids directly.
- Wash your hands fully with soap and warm water before you leave the lab.
What you need
- Go Direct Mini GC1 shared unit · teacher
- Go Direct Wide Range Temperature1 per group
- microliter syringe1 per station · teacher
- Test tubes and rack3 small test tubes and rack
- 250 mL beaker2 per station
- laboratory hot plate1 per group
- clear solution in a reagent bottle1 set of labelled test vials · teacher
- Splash goggles and nitrile gloves1 set per person

Step 1 of 7 Teacher does this
Teacher prepares the reaction tube
- Under the fume hood, your teacher places a boiling stone and 2.0 g of sodium bromide in a large test tube.
- Your teacher adds 1.0 mL of water and 2.0 mL of 1-butanol.
- Cool the tube in an ice-water bath before you add acid.
- Observe how the solid salt begins to dissolve into the liquid mixture.
- The fume hood ventilation operates.
- Teacher wears goggles, lab coat, and purple gloves.
- Students observe from behind the safety sash.
Careful: 1-Butanol vapours can irritate the eyes and nose. Keep all open containers inside the fume hood while the fan runs.

Step 2 of 7 Teacher does this
Teacher adds acid and refluxes the mix
- Your teacher slowly adds 1.5 mL of concentrated sulfuric acid into the chilled tube.
- Clamp the tube into a heated sand bath inside the heat mantle.
- The liquid boils gently so vapours rise, cool, and drip back down (reflux) for 45 to 60 minutes.
- Notice that the liquid turns a rich amber-orange color as the bromine swaps in.
- Concentrated sulfuric acid handled only by teacher.
- The test tube is clamped securely above the heat mantle.
- Condensation ring monitored so vapour does not escape.
Careful: Concentrated acid creates extreme heat and burns skin upon contact. Only the teacher touches the acid and heat equipment. Wear safety goggles.

Step 3 of 7 Teacher does this
Washing and isolating the product
- After the mixture cools, draw off the lower acid layer. Put it into the waste container.
- Wash the rest of the product layer with distilled water, then sodium bicarbonate, then salt water.
- Add a pinch of sodium sulfate salt to absorb leftover water drops.
- Pipette the clear, purified liquid product into a clean labeled vial.
- Glassware has cooled completely to room temperature.
- Waste beaker is clearly labelled for acidic organic waste.
- Students wear goggles and gloves while they watch.
Careful: Sodium bicarbonate releases carbon dioxide gas bubbles that can fizz over. Add wash liquids slowly. Mix gently. Do not shake vigorously.

Step 4 of 7 Teacher does this
Testing the starting material: 1-butanol
- The teacher rinses the micro-syringe twice with acetone, then draws up 0.1 microlitres of pure 1-butanol.
- When the Mini GC LED turns green, insert the needle straight into the injection port.
- Depress the plunger, tap Collect, and immediately withdraw the needle straight out.
- Watch the live signal curve rise and fall as 1-butanol exits the column.
- Syringe needle is perfectly straight and clear.
- Sample volume is exactly 0.1 microlitres (not more).
- The teacher injects smoothly and does not bend the needle.
Careful: A bend in the micro-syringe needle ruins the fragile instrument. Push the needle straight down smoothly. Do not apply sideways force.

Step 5 of 7 Teacher does this
Testing the standard and your product
- Clean the syringe fully with acetone.
- Inject 0.1 microlitres of known 1-bromobutane standard and record its retention time.
- Clean the syringe again, then inject 0.1 microlitres of your synthesised product liquid.
- Compare the peak times: does your product peak match the 1-bromobutane standard?
- Syringe is flushed twice with acetone between injections.
- Cap the vials immediately after you take samples.
- Mini GC shows green Ready light before each run.
Careful: Syringes that are not clean carry leftover liquid. This causes extra unwanted peaks. Wipe the needle tip with a lint-free tissue. Rinse the needle with acetone every time.
2 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 12, Chemistry, chapter 1: Haloalkanes and Haloarenes
- Related Level AS & A Level, Chemistry, chapter 16: Halogenoalkanes
Versions and what each needs
- How do molecules swap parts?
Organic Chemistry, 90 min, Based on a Vernier lab
Needs: Go Direct Mini GC, Go Direct Wide-Range Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.