Experiments › Biology
How do muscles power your grip?
Electromyography and Muscle Force
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can you measure the electric spark behind every muscle squeeze?
Show the answer
Every time you clench your fist, tiny electrical waves pulse through your muscles. Today you will catch those signals with sensors and measure how your body controls strength.

Introduction
The Electric Engines Inside Your Arms
When you pick up a heavy school bag, how does your arm know how hard to pull? Your brain sends rapid electrical commands down your nerves. These signals trigger groups of muscle fibers called motor units. To pull harder, your brain fires more motor units at once. In this experiment, you will measure both the squeezing force and the electrical signals inside your forearm at the exact same instant.
Driving question: How does your nervous system control both the power and duration of a muscle squeeze?
What you will learn
Today you will discover
- I can explain where electrical signals in muscles come from.
- I can record grip force and muscle electrical signals together.
- I can compare the peak spike height and the total signal area on an EMG graph.
- I can observe how contraction duration changes total electrical activity.
- I can describe how engineers and doctors use muscle electrical signals.
Why it matters: Bioengineers use muscle electrical signals to build mind-controlled prosthetic limbs. Sports scientists use them to help athletes train safely.
Safety first
Lab Rules for Muscle Testing
- Educational use only: these sensors are not medical devices and do not diagnose health conditions.
- Do not volunteer if you have pain, arthritis, sprains, or recent injuries in your arm, wrist, or hand.
- Only attach electrode tabs to healthy, unbroken skin. Never place electrodes across the chest or neck.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Do not squeeze the dynamometer past your comfortable limit. Stop immediately if you feel pain.
- Keep liquids far away from the sensors, wires, and tablet.
What you need
- Go Direct Hand Dynamometer1
- Go Direct EKG Sensor1
- Electrode tabs (consumable)3 tabs per volunteer
- Tablet running Graphical Analysis1
- tissue wipes1 wipe

Step 1 of 6
Connect sensors and select EMG channel
- Open Graphical Analysis on your device.
- Turn on the Go Direct EKG Sensor. Connect it with Bluetooth.
- Tap Sensor Channels. Turn off standard EKG. Turn on 'EMG Rectified'.
- Turn on the Go Direct Hand Dynamometer. Connect it. Tap Done.
- Both sensors have charged batteries.
- Bluetooth is enabled on your tablet or computer.
Careful: If you leave standard EKG active, it produces wave-shaped heart signals rather than muscle power spikes. Make sure that you select only 'EMG Rectified' for the EKG sensor.

Step 2 of 6
Zero the hand dynamometer
- Hold the hand dynamometer upright along its smooth plastic edges.
- Do NOT press on the two squeeze pads.
- Wait until the force reading is stable. Tap the Force meter. Choose 'Zero'.
- No fingers rest on the silver squeeze pads.
- The sensor is held still and vertical.
Careful: If you zero the sensor while you touch the pads, you create an artificial negative force offset. Pinch only the outer plastic case from the sides while you zero the sensor.

Step 3 of 6
Attach the three electrode tabs
- Clean the volunteer's inner forearm and upper arm with a wipe. Let the skin dry.
- Stick Tab 1 on the inner forearm, 5 cm below the inner elbow bump.
- Stick Tab 2 on the inner forearm, 10 cm below the elbow in line with the middle finger.
- Stick Tab 3 on the outer upper arm (bicep or shoulder area).
- Skin is clean, dry, and free of lotions.
- The volunteer has no arm, wrist, or skin injuries.
Careful: Dirty or oily skin creates poor contact and noisy electrical spikes. Press firmly on the adhesive borders of each tab so they stick securely.

Step 4 of 6
Clip the sensor leads to the tabs
- Attach the GREEN clip to one of the inner forearm tabs.
- Attach the RED clip to the second inner forearm tab.
- Attach the BLACK clip to the upper arm tab (this acts as the ground reference).
- Make sure that the lead wires hang freely and do not pull on the skin.
- Clips grip the metal snap studs firmly.
- Wires are not twisted or pulled tight.
Careful: Wires that pull can peel tabs off during a strong squeeze. Position the EKG pod on the table close to the arm so wires stay slack.

Step 5 of 6
Part I: Test grip duration (8 s, 5 s, 3 s)
- Have the volunteer sit straight with feet flat. Keep the elbow unsupported at 90°. Tell the volunteer to look away from the screen.
- Trial 1: Tap Collect. Wait 2 seconds. Squeeze at full strength until 10 seconds finish (8 s squeeze).
- Select the squeeze interval on the graphs. Use View Statistics for mean force and peak EMG. Use View Integral for EMG area.
- Repeat for Trial 2 (start squeeze at 5 s = 5 s squeeze). Repeat for Trial 3 (start squeeze at 7 s = 3 s squeeze).
- Subject elbow is at 90 degrees and unsupported.
- Partner is ready to act as timer coach and call out squeeze cues.
Careful: Muscle fatigue can reduce effort if you do trials without rest. Allow the subject 60 seconds of relaxed rest between trials.
1 more step, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Level AS & A Level, Biology, chapter 15: Control and coordination
- Related Level DP, Sports, Exercise and Health Science, chapter 4: Movement Analysis
- Direct Level DP, Sports, Exercise and Health Science, chapter 9: Fatigue
- Direct Level DP, Biology, chapter B3.3: Muscle and motility
Versions and what each needs
- How do muscles power your grip?
Human Physiology Vol 2, 60 min, Based on a Vernier lab
Needs: Go Direct EKG Sensor, Go Direct Hand Dynamometer
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.