Experiments › Physics
How do solar panels make the most power?
Solar Cells
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does a solar panel need the right electrical load to work best?
Show the answer
A solar panel can deliver strong push or heavy flow, but it needs the right balance to deliver maximum power. Today you will track down that sweet spot.

Introduction
Powering Up with Light
Giant solar farms turn bright sunshine into electricity for thousands of homes. But a solar panel does not always deliver its highest possible power. If a circuit resists current too much, flow stops. If a circuit has almost no resistance, voltage drops to zero. In this lab, you will measure how a solar cell behaves across different resistances to find its peak power point.
Driving question: Why does a solar panel produce its highest power at one special circuit setting?
What you will learn
Today you will find out
- I can explain how voltage and current together make electrical power.
- I can connect a solar panel and energy sensor safely in a circuit.
- I can measure changes in voltage and current as electrical resistance changes.
- I can find the sweet spot where a solar panel produces the most power.
- I can explain why real solar systems adjust their electrical load.
Why it matters: Engineers build smart solar inverters that constantly track this peak power point so solar homes get every watt of available clean energy.
Safety first
Lab Safety Rules for Electricity and Lamps
- Wear safety goggles and protective lab gloves during setup and measurements.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Incandescent lamps get very hot. Do not touch the bulb or metal shade during or after use.
- Keep all connection wires neat and flat on the bench so you do not tip the lamp.
- Never short-circuit batteries or mains sockets; use only the low-voltage solar panel.
- Wash your hands with soap when you finish lab work.
What you need
- Go Direct Energy Sensor1
- Solar panel / PV cell kit1
- Vernier Variable Load1
- desk lamp with light bulb1 · teacher
- electrical wire with alligator clips4
- ruler1
- Tablet running Graphical Analysis1
- Splash goggles and nitrile gloves1 per person

Step 1 of 7 Teacher does this
Set up the lamp and solar panel
- Place the solar panel on the table. Turn the panel toward the lamp.
- Have an adult clamp or position the desk lamp directly above the solar panel.
- Use a ruler to set the bulb exactly 20 cm above the panel surface.
- The table surface is dry and uncluttered.
- The lamp power cord is routed safely away from walkways.
- The lamp base sits firmly on the table.
- Do not move the lamp once it is positioned.
Careful: The lamp bulb can get very hot and cause burns if you touch it. If you move the lamp, light intensity changes. Only the teacher touches the lamp fixture. Keep the distance fixed at 20 cm.

Step 2 of 7
Connect panel to the Energy Sensor
- Find the Source terminals on the Go Direct Energy Sensor.
- Connect the red lead from the solar panel to the positive (+) Source terminal.
- Connect the black lead from the solar panel to the negative (-) Source terminal.
- Keep the lamp off while you connect the wires.
- Gloved hands are dry.
- Wires are free of tangles.
- Make sure that the alligator clips clamp tightly onto the metal terminals.
Careful: If you reverse the red and black wires, you get negative voltage readings. Match red wire to positive (+) and black wire to negative (-).

Step 3 of 7
Connect the Variable Load
- Run one wire from the positive (+) Load terminal to one post of the Variable Load.
- Run another wire from the negative (-) Load terminal to the other post.
- Turn the Variable Load dial completely counter-clockwise to its minimum setting (about 2 ohms).
- Panel connects to Source terminals.
- Variable Load connects to Load terminals.
- No bare clips touch each other.
- Locate the Load terminals on the Go Direct Energy Sensor.
Careful: Loose clips create open circuits where zero current can pass. Make sure each alligator clip bites firmly onto clean metal posts.

Step 4 of 7 Teacher does this
Have an adult switch on the lamp
- Have an adult switch on the desk lamp.
- Check that the beam of light illuminates the solar panel evenly.
- Wait 15 seconds for the solar cell to reach a steady temperature.
- Lamp cord is safely plugged in.
- No flammable materials are near the hot bulb.
- Everyone has safety goggles on.
- Keep hands, heads, and shadows away from the light path.
Careful: The lamp bulb becomes hot enough to burn skin instantly upon touch. Never touch the bulb or lamp shade while the lamp is on.

Step 5 of 7
Record low resistance readings
- Tap Collect in Graphical Analysis.
- Notice current is very high (over 300 mA) but potential is low (under 1.0 V) at ~2 to 5 ohms.
- Tap Keep to store your first data point.
- Variable Load is at minimum dial setting.
- No shadows block the lamp beam.
- Live readings are steady.
Careful: A shadow over the solar cell causes a sudden false drop in power. Keep your body and arms to the side of the table away from the lamp beam.
2 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 10, Science, chapter 11: Electricity
- Related Level DP, Physics, chapter 8: B.5 Currents and Circuits
Versions and what each needs
- How do solar panels make the most power?
Physics Explorations, 60 min, Based on a Vernier lab
Needs: Go Direct Current Probe, Go Direct Light and Color Sensor, Go Direct Temperature Probe, Go Direct Energy Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.