Experiments › Earth Science
How do we clean dirty water?
Water Treatment
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Where does clean tap water come from when rivers are muddy?
Show the answer
Tap water starts in rivers and lakes full of mud, minerals, and acids. Water plants clean it in stages: settling, filtering, and chemical balancing. Today you test each stage yourself.

Introduction
The Journey from Muddy to Drinkable
When you turn on the kitchen tap, crystal-clear water pours out. But that water originally came from a river, lake, or underground well. It was filled with floating sand, dissolved mineral salts, and natural acids. Water treatment plants do not turn river water into 100% pure distilled water. Instead, they run it through physical and chemical steps to remove harmful impurities so it meets strict health standards. Today, you take a muddy, acidic water sample through three real treatment steps: settling, filtration, and pH balancing. You will track cloudiness, dissolved minerals, and acidity at every stage.
Driving question: How does muddy river water turn into clean, safe drinking water?
What you will learn
Today you will find out
- I can test water samples using turbidity, conductivity, and pH sensors.
- I can explain why filtering traps solid specks but lets dissolved salts pass through.
- I can observe how balancing pH adds dissolved minerals into water.
- I can evaluate if treated water meets safety rules and explain why clear does not mean pure.
- I can describe how town water plants clean river water before it reaches my tap.
Why it matters: Clean water keeps entire cities healthy. Understanding water testing helps protect our drinking supply and natural waterways.
Safety first
Lab Rules for Water Treatment
- Never drink any water sample during this experiment. Do not drink it after you filter it.
- Wear safety goggles, gloves, and a lab apron at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Handle glassware with two hands over the bench tray.
- Keep liquids at least 30 cm away from tablets and sensor bodies.
- Wipe sensor probes gently with clean tissues; do not bump glass pH bulbs.
- Clean your work area. Then wash your hands fully with soap and water.
What you need
- Go Direct Turbidity Sensor1
- Go Direct Conductivity Probe1
- Go Direct pH Sensor1
- Tablet running Graphical Analysis1
- Plastic cuvette (4 clear sides)1 with lid
- Turbidity Standard (100 NTU)1 cuvette
- 400 mL beaker1 with 200 mL untreated water
- 100 mL beakers1
- plastic funnel made from a jug1
- fluted coffee filter10 filters
- Distilled water wash bottle1
- white chemical powder1 small dish of baking soda with spoon
- Lint-free tissue box1 box

Step 1 of 8
Separate unsettled and settled water samples
- Stir the 200 mL untreated water in your 400 mL beaker with a plastic spoon for 15 seconds.
- Quickly pour about 40 mL of cloudy water into your 100 mL beaker before sand settles.
- Place the 400 mL beaker aside where nobody will touch it for 15 minutes.
- Wear goggles and gloves.
- Work area is clean and flat.
- The 400 mL beaker is set in a quiet spot to settle.
Careful: Do not splash dirty water. Do not shake the beaker after the sand settles. Pour smoothly into the 100 mL beaker and leave the large beaker undisturbed.

Step 2 of 8
Calibrate the Turbidity Sensor
- Fill the turbidity cuvette with distilled water to the white line. Insert it with the marks aligned.
- Tap Calibrate. Set Reading 1 to 0 NTU. Tap Keep.
- Invert the 100 NTU Standard cuvette 4 times, insert it, enter 100 NTU, and tap Keep and Apply.
- Turbidity sensor warmed up for at least 5 minutes.
- Lint-free tissue is ready.
- Standard cuvette is never shaken.
- Wipe cuvettes with a lint-free tissue before you put them into the sensor.
- Do not shake the 100 NTU Standard cuvette.
Careful: Bubbles or fingerprints on cuvettes cause false turbidity readings. Wipe the cuvette with lint-free wipes. Tap the bottom gently to remove bubbles.

Step 3 of 8
Test unsettled water for TDS and pH
- Stir the 100 mL beaker sample with a spoon just before the test.
- Lower the Conductivity probe until the hole near its tip is under water. Record TDS (mg/L).
- Put the rinsed pH sensor into the sample. Record the pH.
- Stir the sample immediately before you measure it.
- Waste cup is positioned next to beakers.
- Rinse probe tips fully between tests.
- Rinse the Conductivity probe tip with distilled water over your waste cup.
- Remove the pH sensor from its storage solution and rinse with distilled water.
Careful: Do not touch the glass pH bulb against the beaker bottom. It can crack. Hold the probe suspended in the middle of the liquid. Do not hit the glass against the beaker.

Step 4 of 8
Test turbidity of unsettled water
- Stir the 100 mL beaker again so particles stay suspended.
- Fill the cuvette to the white line. Screw the cap on. Invert it gently 4 times.
- Place the cuvette into the Turbidity Sensor, align marks, close the lid, and record quickly.
- Cuvette outside is wiped completely dry.
- Read quickly because particles settle over time.
- Rinse the cuvette with sample water before you fill it.
- Wipe the outside of the cuvette with a lint-free tissue.
Careful: Sand settles if you wait too long. This makes the turbidity value drift downward. Take your reading within 10 to 15 seconds after inverting and placing the cuvette.

Step 5 of 8
Decant and test settled water
- Empty and dry your 100 mL beaker, then carefully decant 40 mL of clear liquid from the 400 mL beaker.
- Do not stir the settled water. Measure TDS, pH, and Turbidity. Record the values.
- Record the values and discard the settled water. Rinse and dry your 100 mL beaker for filtration.
- The 400 mL beaker was undisturbed for 15 minutes.
- Pour slowly and stop before sand slides out.
- Do not stir settled water before you test it.
- Check that heavy sand grains have settled to the bottom of the 400 mL beaker.
- Do not disturb sand at the bottom while you pour the liquid.
Careful: If you tilt the beaker too fast, settled sand swirls back into the water. Pour slowly and steadily. Leave the thick sludge at the bottom.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 6, Science, chapter 9: Methods of Separation in Everyday Life
- Related Class 9, Science, chapter 2: Is Matter Around Us Pure?
- Related Class 6, Chemistry, chapter 5: Separation of Components of a Mixture
- Direct Class 6, Biology, chapter 7: Health and Hygiene
- Related Class 6, Chemistry, chapter 9: Water as Universal Solvent and its Pollution and Prevention
- Related Level AS & A Level, Biology, chapter 10: Infectious disease
Versions and what each needs
- How do we clean dirty water? (Earth Science)
Earth Science, 55 min, Based on a Vernier lab
Needs: Go Direct Conductivity Probe, Go Direct pH Sensor, Go Direct Turbidity Sensor - How do we clean dirty water? (Environmental Science)
Environmental Science, 80 min, Based on a Vernier lab
Needs: Go Direct Conductivity Probe, Go Direct pH Sensor, Go Direct Turbidity Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.