Experiments › Biology
How do your muscles fire?
Muscle Function
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does a tennis player feel pain in their elbow after swinging a racquet?
Show the answer
Every time your fingers grip and pull, tiny electric sparks shoot through your forearm muscles. Today you will hook up an EMG sensor to eavesdrop on those electrical signals and discover how changing your hand grip can save your joints from injury.

Introduction
How Do Your Muscles Fire?
When you pick up a book or carry a heavy bag, your brain sends electrical commands down your nerves. Your muscle cells respond with tiny electrical pulses of their own. If you repeat the same hard grip over and over, the tendons at your elbow can become sore and inflamed: a condition known as tennis elbow. Today, you will measure the real electrical signals in your forearm to see how different hand positions change the strain on your muscles.
Driving question: Why does lifting a heavy pan the wrong way give you a painful elbow?
What you will learn
Today you will find out
- I can explain how an EMG sensor detects muscle contraction.
- I can observe the burst of electrical spikes when a muscle contracts.
- I can conclude which lifting grip strains forearm extensor muscles the least.
- I can place electrodes and attach sensor leads in the correct positions.
- I can suggest safer ways to lift heavy objects and type to avoid muscle strain.
Why it matters: Physical therapists, sports coaches, and doctors use EMG signals every day to treat injuries and help athletes move without pain.
Safety first
Scientist Rules for Today
- Wear clean gloves when you place electrode tabs on another person's skin.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Do not volunteer if you currently have pain, arthritis, or an injury in your wrist, hand, or elbow.
- Move only your wrist joint to lift weights. Never jerk, drop, or swing the weight.
- If you feel any discomfort or sharp fatigue, stop immediately and rest your hand.
- For educational use only. Use this sensor only for science study. Do not use this sensor for medical diagnosis.
What you need
- Go Direct EKG Sensor1
- Electrode tabs (consumable)3
- 1–2 kg (3 lb) weight (barbell or similar)1
- ruler1
- Tablet running Graphical Analysis1

Step 1 of 8
Connect and configure the sensor
- Turn on the Go Direct EKG Sensor and pair it with Graphical Analysis.
- Tap Sensor Channels. Turn OFF the EKG channel. Turn ON 'EMG Rectified'.
- Tap Data Collection settings: set Rate to 100 samples/s and Duration to 25 s.
- Tablet Bluetooth is turned on.
- Sensor battery is charged.
- The sensor box rests safely on the table.
Careful: If you leave EKG selected instead of EMG Rectified, the sensor records heart waves that confuse results instead of muscle spikes. Double-check that only 'EMG Rectified' has a checkmark beside it.

Step 2 of 8
Place the three electrode tabs
- Rest your forearm flat palm DOWN and locate the lateral epicondyle: the bony bump on your outside elbow.
- Use a ruler to measure 5 cm and 10 cm along an imaginary line toward the middle finger.
- Stick two tabs on these forearm spots. Stick a third tab on the upper arm.
- Skin is clean and dry.
- Volunteer has no wrist or arm pain.
- Tabs stick flat with no peeled edges.
Careful: Tabs placed over oily skin or loose clothes give noisy baseline readings. Press firmly on the adhesive rim of each tab for 5 seconds.

Step 3 of 8
Snap the leads onto the electrodes
- Snap the RED clip onto one forearm tab.
- Snap the GREEN clip onto the other forearm tab (red and green can swap places).
- Snap the BLACK clip (the ground reference) onto the upper arm tab.
- Clips grip the metal studs tightly.
- Wires are slack and do not pull on the tabs.
- Volunteer is comfortable.
Careful: If you pull on the wire, you can unseat the electrode tab from the skin. Keep the sensor body close to the elbow so the wires have plenty of slack.

Step 4 of 8
Test for a stable baseline
- Rest your fingertips gently on the table. Hold your palm above the table in line with your forearm.
- Tap Collect and watch the live graph for 5 seconds.
- If the baseline is flat and low (below 0.02 mV), tap Stop: you are ready!
- If it is jumpy or noisy, press the tabs firmer or relax your hand completely.
- The subject stands in a relaxed posture and faces the table.
- The forearm rests on the bench without tension.
- Wires do not sway in the air.
Careful: If you shift your posture or move your fingers, electrical noise ruins your baseline. Keep your shoulder and elbow completely still while your fingertips rest on the wood.

Step 5 of 8
Trial 1: Free hand extension (no weight)
- Tap Collect to begin the 25-second test.
- 0 to 5 s: rest fingertips quietly on the table.
- 5 to 10 s: bend wrist back to extend your hand as far as comfortable; hold 5 s.
- 10 to 15 s: relax fingertips back on the table.
- 15 to 20 s: extend your hand again for 5 s, then rest until 25 s ends.
- The partner watches the screen timer to call out 5-second marks.
- Subject moves only the wrist; forearm stays flat on the table.
- No pain during extension.
Careful: If you lift the whole forearm off the table, elbow and shoulder muscles introduce noise. Keep the forearm glued to the bench and pivot only the wrist.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 11, Biology, chapter 17: Locomotion and Movement
- Direct Class 9, Biology, chapter 12: Skeleton Movement and Locomotion
- Related Level AS & A Level, Biology, chapter 15: Control and coordination
- Direct Level DP, Sports, Exercise and Health Science, chapter 4: Movement Analysis
Versions and what each needs
- How do your muscles fire?
Human Physiology Vol 2, 75 min, Based on a Vernier lab
Needs: Go Direct EKG Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.