Experiments › Physics
How does a radio pick one station?
RLC Circuits
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 9 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does turning a dial bring one radio song out of thin air?
Show the answer
Thousands of radio waves pass through your room at once. A tiny electrical team inside the radio vibrates at only one exact speed. Today, you will build that team and watch it light up.

Introduction
The Secret Tuning Trick
When you turn on a radio, your room is filled with music, news, and chatter from dozens of different stations. All these signals travel through the air as invisible electrical waves, each wiggling at its own frequency. How does your radio pick just one and ignore the rest? Inside every tuner is an RLC circuit: a team of three parts called a resistor, an inductor, and a capacitor. Working together, they welcome one exact frequency while blocking all others. In this lab, you will wiggle electricity back and forth to find that magic frequency and make a light bulb glow.
Driving question: How can an electrical circuit pick out just one frequency from the air?
What you will learn
Today you will discover
- I can explain how alternating current moves back and forth.
- I can show that fast alternating current passes through a capacitor more easily.
- I can tell how an inductor blocks fast electrical wiggles.
- I can find the sweet spot where an RLC circuit lets the most current through.
- I can name real devices that use circuit resonance.
Why it matters: Radio tuners, wireless chargers, metal detectors, and Wi-Fi routers all depend on electrical resonance to select signals.
Safety first
Laboratory Electrical Rules
- Wear safety glasses and protective lab gloves throughout the experiment.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Make sure an adult supervises you when you operate the Power Amplifier and Frequency Generator.
- Never exceed the voltage and current limits specified in the procedure.
- Switch off the Power Amplifier before you move or clip any wire lead again.
- Do not touch components while AC power is on. Resistors and coils can warm up.
- Report loose wires, pinched cords, or unexpected sparks to an adult immediately.
What you need
- Vernier Circuit Board 21 per group
- Vernier Power Amplifier1 per group · teacher
- Frequency Generator with BNC cable1 per group · teacher
- Go Direct Current Probe1 per group
- Go Direct Voltage Probe1 per group
- Electrical wire clip leads with alligator clips6 leads per group
- Powdered iron core cylinder1 per group
- Tablet running Graphical Analysis1 per group

Step 1 of 9 Teacher does this
Connect and power the signal source
- Connect the Frequency Generator to the Power Amplifier with the BNC-to-audio cable.
- Turn on the Frequency Generator. Set amplitude to 0.4.
- Set the start frequency to 20 Hz.
- The Power Amplifier switch is OFF before you connect cables.
- Amplitude is checked to be 0.4, not 4.0.
- Mains cords are kept clear of walkway paths.
- Confirm amplitude 0.4 creates a safe plus-or-minus 2-Volt AC test signal.
Careful: Accidentally setting the generator amplitude too high can trip the amplifier fuse or overheat circuit parts. Make sure that the digital display shows 0.4 AMPL and 20 Hz FREQ before you turn on amplifier power.

Step 2 of 9
Wire the capacitor test circuit
- Connect clip leads from Power Amplifier red and black terminals to External input terminals.
- Clip the Go Direct Current Probe in series with the 10 microfarad capacitor.
- Clip the Go Direct Voltage Probe leads across the capacitor terminals.
- The Power Amplifier power is OFF while you clip wires.
- Switch SW1 is set to Battery position.
- Alligator clips grip turret posts firmly and do not touch adjacent posts.
- Make sure switch SW1 on the board is in the Battery position.
Careful: Alligator clips that touch adjacent turrets can cause a short circuit. Clip leads straight down onto the round turret posts so metal collars do not touch.

Step 3 of 9
Measure capacitor current versus frequency
- Turn on the Power Amplifier. Tap Collect in Graphical Analysis.
- Use View Statistics to find the maximum current and voltage.
- Increase frequency to 100 Hz, 200 Hz, 500 Hz, and 1000 Hz. Collect data at each step.
- Switch SW1 is set to External.
- The green LED on the Power Amplifier is illuminated.
- Probes are reading live data on the tablet.
- Flip switch SW1 to External to close the circuit.
Careful: If you change frequency while you touch bare metal clips, connections can loosen. Use the dial on the frequency generator to adjust frequencies; do not pull wire leads.

Step 4 of 9
Switch to the inductor circuit
- Place a 10 Ohm resistor in series with the 5.0 mH inductor coil and Current Probe.
- Clip the Voltage Probe across both the resistor and the inductor coil.
- Flip SW1 to External and turn the Power Amplifier back on.
- The Power Amplifier is OFF before you disconnect leads.
- The 10 Ohm resistor is included in the circuit loop.
- Voltage probe clips firmly over the whole RL section.
- Switch off the Power Amplifier and flip SW1 back to Battery.
Careful: If you omit the 10 Ohm resistor, excessive current can flow at low frequencies. Always keep the 10 Ohm resistor in series with the inductor coil.

Step 5 of 9
Measure inductor current versus frequency
- Set the Frequency Generator to 100 Hz. Tap Collect.
- Record the maximum current with View Statistics.
- Gradually increase frequency from 100 Hz up to 1000 Hz. Record peak current at each step.
- Power Amplifier is ON.
- Amplitude remains steady at 0.4.
- One student records values while another adjusts frequency.
Careful: The coil can warm up slightly if left at 100 Hz for several minutes. Advance through frequencies smoothly. Do not pause the circuit on one setting.
4 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 12, Physics, chapter 7: Alternating Current
Versions and what each needs
- How does a radio pick one station? (function generator)
Advanced Physics, 80 min, Based on a Vernier lab
Needs: Go Direct Current Probe, Go Direct Voltage Probe - How does a radio pick one station? (power amplifier)
Advanced Physics, Based on a Vernier lab
Needs: Go Direct Current Probe, Go Direct Voltage Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.